PIM00413
12-8
Note
The parameter setting value of pressure or flow rate is limited as follows.
(1) High-pressure side pressure setting value
≥
Low-pressure side pressure setting value
(2) Low-pressure side flow rate setting value
≥
High-pressure side flow rate setting value
When the parameter setting value of High-pressure side pressure setting, Low-pressure side
pressure setting, Low-pressure side flow rate setting or High-pressure side flow rate setting
changes, if its setting value reaches the above conditions, every Low-pressure side pressure
setting value or High-pressure side flow rate setting value in (1) or (2) will be automatically
changed as follows.
(1) Low-pressure side pressure setting value = High-pressure side pressure setting value
(2) High-pressure side flow rate setting value = Low-pressure side flow rate setting value
Pressure and flow rate characteristic curve can be set by the parameter as shown in the figure below.
低圧(合流)
流量
高圧(単独)
0
圧力
「PH*:高圧側
圧力設定」
「PL*:低圧側
圧力設定」
「QH*:高圧側
流量設定」
「QL*:低圧側
流量設定」
◆自律切替運転時
Frow rate
0
Pressure
「PL*:Pressure setting」
「QL*:Frow rate setting」
* Please refer to "12.3.3 [P40: PL_D] Settings when operating only at high pressure side (single) " for more
information about how to set the high-pressure and low-capacity operation.
12.3.2
PQ selection
The PQ number can be selected by switching the digital input signal. The pressure command, the flow rate
command which is set by the parameter in advance can be switched.
In addition, the acceleration or deceleration time of pressure / flow rate at the time of switching PQ number also
can be changed.
QL*:Low-pressure side
Flow rate setting
QH*:High-pressure side
Flow rate setting
PL*:Low-pressure side
pressure setting
PH*:High-pressure side
pressure setting
Pressure
Flow rate
◆Self-switching operation
QL*:Low-pressure side
Flow rate setting
◆High pressure pump operation
PL*:Low-pressure side
pressure setting
Summary of Contents for SUT00D4016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30 ...
Page 21: ...PIM00413 3 7 SUT00S6007 30 ...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension ...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30 ...
Page 24: ...PIM00413 3 10 SUT06S6007 30 ...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2 ...
Page 26: ...PIM00413 3 12 SUT10D6021 30 ...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......