PIM00413
12-13
◆
Digital output DO2 and contact output
Parameter Output
signal
P08
Alarm
mix output
P07
Warning
output level
Digital output DO2
Contact output
0
Alarm
ON: Normal
OFF: Alarm
1
Alarm or Warning
ON: Normal
OFF: Alarm
ON
⇔
OFF: Warning
0 or 2
2
Alarm or Warning
ON: Normal
OFF: Alarm or Warning
Pressure switch
0
Alarm or Pressure switch
1
1
2
No output
Alarm or Pressure switch or Warning
12.5
Pressure switch setting
By the pressure switch function, the digital signal detecting the pressure decrease can be output.
By this function, the external pressure switch is not required. So, the system can be formed at low cost.
Please refer to "12.4.1 Parameters" for the method of setting the pressure switch output signal.
12.5.1
Parameters list
No. Sign
Parameter
Name
Range
Factory Default
Setting
Unit
0
〜
35.0
(
0: Function disabled
)
0.0 MPa
0
〜
507
(
0: Function disabled
)
0.0 ×10PSI
P01 SW_L
Pressure switch operating
level
0
〜
350
(
0: Function disabled
)
0.0 %
P02 T_SW
Pressure switch output delay
time
0.00
〜
9.99
0.00 sec
P03 PSWH
Pressure switch display
holding setting
0: Invalid
1: Display hold
2: Display and record
0
−
P08 AMIX
Alarm
output
mix
0: Individual output
1: Integrated output
2: Pressure switch function
expansion
1 -
0.00
〜
1.00
0.50 MPa
P38 P_DF
Pressure switch output dead
zone
0
〜
145
72 PSI
Summary of Contents for SUT00D4016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30 ...
Page 21: ...PIM00413 3 7 SUT00S6007 30 ...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension ...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30 ...
Page 24: ...PIM00413 3 10 SUT06S6007 30 ...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2 ...
Page 26: ...PIM00413 3 12 SUT10D6021 30 ...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......