Monitor mode
11.4.1
Monitor mode display item list
In monitor mode, you can monitor the items in the table below by panel operation.
Monitor
number
Name Unit
Remarks
MPa
n00
Pressure switch setting
value
×10PSI
Displays the pressure switch setting.
MPa
n01 Pressure
setting
value
×10PSI
Displays the pressure settings of the current P-Q selection
number.
n02
Flow rate setting value
L/min
Displays the flow rate settings of the current P-Q selection
number.
n03
Flow rate
L/min
Displays the current flow rate.
n04
Latest alarm code
−
Displays the latest alarm code.
Press the
key, you can check the number of power-on
times.
n05 rpm
×10min
-1
Displays the current rpm.
n06 Operating
status
−
Displays the PQ selection number. "L" is a fixed sign.
(Example)
low pressure (confluence) PQ selection
No.1
n07
Reverse rpm at power-
OFF
min
-1
Displays a motor reverse rpm due to counter-flow from the load
when the unit power supply is turned OFF. This parameter is
used to estimate the machine load volume.
n08
Regenerative load
integration ratio
%
Displays the load integration ratio of the current regenerative
braking resistance.
n09
(Reserved for system)
―
Reserved
for
system
n10
Motor thermistor
temperature
℃
Displays the temperature detected by the thermistor in the
motor.
n11
Fin thermistor
temperature
℃
Displays the temperature detected by the thermistor in the fin.
n12
Main circuit DC voltage
V
Displays the controller’s internal DC voltage. The voltage value
is indicated as power supply voltage multiplied by
√
2. The
voltage value may change depending on its operating
conditions.
n
13
Analog input voltage 1
V
Displays the input voltage of the analog input terminal AIN1.
n14
Analog input voltage 2
V
Displays the input voltage of the analog input terminal AIN2.
n15
Analog output voltage 1
V
Displays the output voltage of the analog output terminal AO1.
n16
Analog output voltage 2
V
Displays the output voltage of the analog output terminal AO2.
n17
(Reserved for system)
―
Reserved
for
system
n18
(Reserved for system)
―
Reserved
for
system
n19
(Reserved for system)
―
Reserved
for
system
n20
(Reserved for system)
―
Reserved
for
system
n21
(Reserved for system)
―
Reserved
for
system
n22
(Reserved for system)
―
Reserved
for
system
Summary of Contents for SUT00D4016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30 ...
Page 21: ...PIM00413 3 7 SUT00S6007 30 ...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension ...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30 ...
Page 24: ...PIM00413 3 10 SUT06S6007 30 ...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2 ...
Page 26: ...PIM00413 3 12 SUT10D6021 30 ...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......