PIM00413
12-7
CAUTION
The standard factory setting of "P04: Pressure unit select setting" is MPa.
When it was changed to PSI display, please adhere a seal to make it understand easy. Please prepare the display
seal. However, If it is used in Japan, you will be punished by the Measurement Law.
12.2
[P00: DI_A] Valid logic switch of the start-stop signal
You can make the motor start / stop by the input signal of the digital input terminal DIN1.
This parameter allows you to switch the effective logic of the digital input terminal DIN1.
No. Sign
Name
Setting
Range
Factory
Settings
Unit
P00 DI_A
Start-stop signal
switch
0: Pump starts to run when the DIN1
is ON
1: Pump starts to run when the DIN1
is OFF
1 -
DIN1 Terminal State
Settings
OFF ON
0
Pump stop
Pump start
1
Pump start
Pump stop
CAUTION
Frequently turning ON / OFF the power supply may damage the controller.
Please turn ON / OFF the pump by the digital input terminal DIN1 except in an emergency.
Note
If it is used without a start-stop signal, by setting the value as "1", the hydraulic unit will start
automatically at power-on.
12.3
Pressure / flow rate property and PQ selection
12.3.1
PQ selection parameter
You can set several parameters in every PQ selection number, such as, maximum pressure, maximum flow rate,
acceleration and deceleration time of pressure / flow rate at the time of switching PQ number.
Display
Sign *
Parameter Name
Unit
PH*
High-pressure side
pressure setting
MPa
QH*
High-pressure side
flow rate setting
L/min
PL*
Low-pressure side
pressure setting
MPa
QL*
Low-pressure side
flow rate setting
L/min
UT*
Acceleration time
setting
“P13: PQ selection 0”
〜
“P28: PQ selection 15”
DT*
Deceleration time
setting
sec/MPa
sec/1000min
-1
* : The PQ selection number (hexadecimal) is displayed in the *.
Summary of Contents for SUT00D4016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30 ...
Page 21: ...PIM00413 3 7 SUT00S6007 30 ...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension ...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30 ...
Page 24: ...PIM00413 3 10 SUT06S6007 30 ...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2 ...
Page 26: ...PIM00413 3 12 SUT10D6021 30 ...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......