PIM00413
12-3
Item Sign
Name
Operating
range
Default
setting
Description Reference
surge pressure is more likely to occur.
In addition, if set to 0, the acceleration
response gain will become the maximum
that is defined by the controller. And the
acceleration time will become the
minimum.
P12 W_TM
Solenoid valve
response delay
time
0.00
〜
9.99[sec]
0
After switching the PQ pattern, it will
change the pressure command or the flow
rate command after a delay determined
by this parameter.
Please adjust it, if you want to change
pressure or flow rate, and avoid the
instability in switching solenoid valve.
エラー
!
ブ
ックマーク
が定義さ
れていま
せん。
PQ selection number 0 ~ 15
MPa
PL.0
〜
PL.F
Low-pressure side
pressure setting ×10PSI
Setting the target pressure.
qL.0
〜
qL.F
Low-pressure side
flow rate setting
L/min
Setting the target flow rate (theoretical).
Make sure the setting value does not
exceed the low pressure side flow setting.
MPa
PL.0
〜
PL.F
Low-pressure side
pressure setting ×10PSI
Set the target pressure of the low-pressure
side (pump confluence).
The setting value is limited, so as not to
exceed the high pressure side pressure
setting.
By setting this parameter to "0", high-
pressure small-capacity operation can be
selected.
Please refer to:
"12.3.3 [P40: PL_D]
Settings when operating only at high
pressure side (single) " for more
information.
qL.0
〜
qL.F
Low-pressure side
flow rate setting
L/min
Set the target flow rate (theoretical value)
of the low-pressure side (pump
confluence)
Ut.0
〜
Ut.F
Acceleration time
setting
0.01
〜
99.99
[sec/MPa]
[sec/1000min
-1
]
Setting the change time, when the
pressure command or flow rate command
is increased at the time of switching the
PQ pattern.
・
Pressure command: Increase 1MPa
time.
・
Flow rate command: Increase
1000min-1 time.
P13
〜
P28
dt.0
〜
dt.F
Deceleration time
setting
0.01
〜
99.99
[sec/MPa]
[sec/1000min
-1
]
Please
refer to
12-6
Table 2
Setting the change time, when the
pressure command or flow rate command
is decreased at the time of switching the
PQ pattern.
・
Pressure command: Decrease 1MPa
time.
・
Flow rate command: Decrease
1000min-1 time.
12-7
P29 C_TM
High/Low
switching
response time
0.05
〜
1.00[sec]
Please
refer to
12-6
Table1
The waiting time between the next
switching and the last switching.of pump.
Because of the pressure and flow rate
changing after pump swiching, the pump
switching may occur frequently. Set this
−
Summary of Contents for SUT00D4016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30 ...
Page 21: ...PIM00413 3 7 SUT00S6007 30 ...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension ...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30 ...
Page 24: ...PIM00413 3 10 SUT06S6007 30 ...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2 ...
Page 26: ...PIM00413 3 12 SUT10D6021 30 ...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......