PIM00413
9-1
Chapter 9 Electric Wiring
・
This hydraulic unit needs connections of main power cables and I/O signal cables as required.
・
Please remove the controller cover by loosening and removing the Cross head screws M4×4, then connect the
main power cables and I/O signal cables. After completing the wiring, please replace the controller cover. The
recommended tightening torque is 1.0 N
・
m.
・
Connect the main power cable and I/O signal cables through the specified wiring holes.
・
In order to protect the electric circuit against short-circuiting and overcurrent and prevent electric shocks, the
hydraulic unit main power supply must be equipped with a no-fuse breaker conforming to European Norm
EN60947-2.
・
For the power supply connection device, use a switch that provides 3 mm or longer contact distance for three
electrodes in the OFF status.
Controller cover mounting screws
(M4 × 4)
Recommended torque 1N · m
Controller cover
I/O single wiring port
φ
21
Main power supply
wiring port
φ
28
DANGER
●
Please attach the no fuse breaker that conforms to the European standard EN60947-2 to the power line, in
order to reduce the risk of electric shock and protect the electrical circuit against over-current or short-
circuit. (Please refer to "9.2 Installation of breaker" for the capacity of each model.)
●
Please connect the ground terminal by the D class grounding method (formerly Class 3 grounding).
(
Please directly connect, do not go through the breaker.)
●
Before connecting the cables, please wait 5 minutes after turning off the main power supply. There is a risk
of electrical shock.
●
Do not apply an excessive power supply voltage higher than the power supply rating of the hydraulic unit.
Otherwise, the controller may be damaged.
●
Please do not make cables and terminals short circuit or ground fault. There is a risk of electrical shock or
fire.
●
When you peel the wires, please be careful not to scratch the conductor.
●
Please use the cable clamp and multi-core cable for wiring, make sure the wiring satisfy the IP54 protection
grade or more.
Summary of Contents for SUT00D4016-30
Page 2: ......
Page 12: ......
Page 20: ...PIM00413 3 6 3 4 Dimensions Motor Pump Type SUT00 SUT00S3016 30 ...
Page 21: ...PIM00413 3 7 SUT00S6007 30 ...
Page 22: ...PIM00413 3 8 SUT00D4016 30 SUT00D6021 30 Product type Dimension ...
Page 23: ...PIM00413 3 9 Unit Type SUT06 SUT10 SUT06S3016 30 ...
Page 24: ...PIM00413 3 10 SUT06S6007 30 ...
Page 25: ...PIM00413 3 11 SUT06D4016 30 SUT06D6021 30 1 1 327 for SUT06D6021 30 2 188 for SUT06D6021 30 2 ...
Page 26: ...PIM00413 3 12 SUT10D6021 30 ...
Page 36: ......
Page 38: ......
Page 42: ......
Page 54: ......
Page 64: ......