2
|
Components
Service manual
103
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01C – 2020.07
2
Open the compressor insulation.
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10 V DC before proceeding.
3
Remove the cover of the compressor wire terminals.
a
a
Compressor wire terminals cover
4
Disconnect the connector.
5
Remove the clip and remove the reactor from the compressor.
6
To install the reactor, see
102].
To install the reactor
1
Install the reactor in the correct location and install the clip.
2
Connect the reactor connector.
3
Install the cover of the compressor wire terminals.
a
a
Compressor wire terminals cover
4
Install the compressor insulation.
Is the problem solved?
Action
Yes
No further actions required.