6

English

13.

High side equalizer accessory pipe (1)

14.

L type accessory joint (1)

15.

L type accessory joint (2)

16.

Liquid side accessory pipe (2)

17.

Low side equalizer accessory pipe (2)

18.

Gas side accessory pipe (1)

19.

High side equalizer accessory pipe (2)

20.

Installation for mult: system

(Refer to figure 13-2)

1.

When connected to the front

2.

When connected at lateral side (bottom)

3.

Remove the shutoff valve cover to connect.

4.

Remove the knock hole on the bottom frame and route the 
piping under the bottom frame.

5.

Liquid pipe shutoff valve

6.

Gas pipe shutoff valve

7.

Brazing

8.

Liquid side accessory pipe (1)

9.

Gas side accessory pipe (1)

10.

L type accessory joint (2)

11.

Liquid side accessory pipe (2)

12.

Gas side accessory pipe (1)

13.

Installation for single unit system

NOTE

Equalizer pipe is only for connection between outside units on multi 
outside unit system.
That is not connect to indoor units.

Make sure the onsite piping does not come into contact with other 
piping or the bottom frame or side panels of the unit.

4.

Precautions when connecting piping between outside units
The Outside unit multi connection piping kit (sold separately) is 
needed to connect piping between outside units in multi system. 
Only proceed with piping work after considering the limitations on 
installation listed here and in 

“5. Branching the refrigerant pip-

ing”

, always referring to the kit’s installation manual.

(1)

About outside unit multi connection piping kit

Install the joint horizontally so that the attached warning label 
faces strait up, and the tilt is within ±15°. 

(Refer to figure 16-1)

Do not install vertically. 

(Refer to figure 16-2)

Maintain a straight portion of 19-5/8 in. or more until the split of 
the joint without wrapping any onsite piping around this area. 
Over 19-5/8 in. of straight area can be maintained by connect-
ing at least 4-3/4 in. of onsite pipe (straight) to the joint.

(Refer to figure 16-3)

(Refer to figure 16)

1.

Warning label

2.

Horizontal surface

3.

±15° or less

4.

Ground

5.

Onsite pipe (4-3/4 in. length or more)

6.

Straight part of 19-5/8 in. or more

7.

C-arrow view

8.

D-arrow view

(2)

The piping between outside units must be installed level (Pattern 
1) or with a rise (Pattern 2). Otherwise oil may pool in the pipes.

(3)

To avoid the risk of oil detention in the stopping unit, always con-
nect the shutoff valve and the piping between outside units as 
shown A or B in the figure below.

Pattern 1

Pattern 2

Prohibited pattern

Change to pattern 1 or pattern 2

to indoor unit

to indoor unit

to indoor unit

to indoor unit

Piping between outside units

to indoor unit

Piping between outside units

Downward inclination

Downward inclination

Oil remains in piping

Front connections

Side (bottom) connections

Front connections

Side (bottom) connections

Front connections

Side (bottom) connections

Level

Rise

Downward
inclination

Unit

A

Unit

B

Unit

A

Unit

B

Unit

A

Unit

B

Unit

A

Unit

B

Unit

A

Unit

B

Unit

A

Unit

B

Rise

Rise

to indoor
unit

A

B

A

B

Front connections

Side (bottom) connections

01_EN_3P215731-2.fm  Page 6  Tuesday, December 4, 2007  12:04 PM

Summary of Contents for RXYQ120PYDN

Page 1: ...INSTALLATION MANUAL System air conditioner RXYQ72PYDN RXYQ96PYDN RXYQ120PYDN RXYQ144PYDN RXYQ168PYDN RXYQ192PYDN RXYQ216PYDN RXYQ240PYDN English Fran ais Espa ol...

Page 2: ...8 11 3 4 Pattern 3 2 1 2 1 60 3 1 4 2 5 2 in 40 4 0 40 6 0 60 60 figure 1 figure 3 figure 2 4 1 2 3 1 1 2 3 7 8 3 7 8 3 7 8 5 3 7 8 3 7 8 3 7 8 1 2 3 4 5 figure 4 figure 6 figure 5 A B 1 4 3 2 30 1 8...

Page 3: ...4 1 5 2 B 1 2 1 1 1 1 5 16 1 16 2 16 3 6 2 3 4 4 C D 7 8 3 4 6 7 1 1 2 3 4 5 2 1 4 3 2 1 3 1 1 2 6 1 2 7 5 TOIN DUNIT F1 F2 TOOUT DUNIT F1 F2 TOMULTIUNIT Q1 Q2 A1P TOMULTIUNIT Q1 Q2 2 4 A1P 8 F1 F2 F1...

Page 4: ...re 30 figure 32 figure 28 figure 24 1 2 3 4 5 6 7 8 9 10 12 11 1 2 3 4 5 6 7 8 9 10 13 15 15 16 F17 11 12 19 20 14 18 1 2 1 2 3 1 2 3 4 5 1 2 2 3 5 6 4 1 2 3 4 10 13 11 5 6 7 8 9 12 15 16 17 18 14 1 2...

Page 5: ...ired to take adequate measures Meaning of danger warning caution and note symbols DANGER Indicates an imminently hazardous situa tion which if not avoided will result in death or serious injury WARNIN...

Page 6: ...e may occur Do not use a charging cylinder Using a charging cylinder may cause the refrigerant to deteriorate The refrigerant R410A requires strict cautions for keeping the system clean dry and tight...

Page 7: ...he storage location of the accessories is shown in figure 1 NOTE Do not throw away any of the accessories until installation is complete They are needed for installation work Refer to figure 1 1 Clamp...

Page 8: ...HANDLING THE UNIT At delivery the package should be checked and any damage should be reported immediately to the carrier claims agent When handling the unit take into account the following 1 Fragile...

Page 9: ...s when brazing the pipe joints Residue can clog pipes and break equipment 6 4 Connecting the refrigerant piping 1 Direction to bring out the pipes The local inter unit piping can be connected either f...

Page 10: ...anual 1 About outside unit multi connection piping kit Install the joint horizontally so that the attached warning label faces strait up and the tilt is within 15 Refer to figure 16 1 Do not install v...

Page 11: ...stall the REFNET header so it splits horizontally Refer to figure 15 1 Horizontal surface 2 B arrow view Prohibited pattern Oil remains in the stopping outside unit Change to pattern 1 or pattern 2 Fr...

Page 12: ...0 ft Example 6 a b h 540 ft 8 a i j 540 ft Example 8 a i 540 ft Equivalent pipe length between outside unit 2 and indoor unit 620 ft Note 1 Assume eqivalent pipe length of REFNET joint to be 1 6 ft th...

Page 13: ...t total capacity index 72 72 111 111 Number of outside unit 2 units Connecting piping kit name BHFP22P100U Refrigerant branch kit name KHRP26M22H or KHRP26M33H KHRP26M33H KHRP26M72H Example for indoor...

Page 14: ...249 0 121 0 040 0 175 0 081 0 015 HEAT PUMP SYSTEM MODEL NAME THE AMOUNT OF REFRIGERANT RXYQ72 120PYDN RXYQ144 192PYDN RXYQ216 240PYDN 2 2 lb 3 3 lb REFRIGERANT AMOUNT FOR EXCEEDING CONNECTION CAPACI...

Page 15: ...ing and earth terminal If there exists the possibility of reversed phase lose phase momen tary blackout or the power goes on and off while the product is oper ating attach a reversed phase protection...

Page 16: ...d of the master unit The outside unit that connected transmission wiring to indoor unit is the master unit The others are sub unit 7 5 Power Wiring Connection Procedure Be sure to connect the power su...

Page 17: ...shipped the unit contains the refrigerant so use caution when attaching the charge hose Air tight test Pressurize the liquid pipe suction gas pipe HP LP gas pipe and equalizer pipe from the service po...

Page 18: ...d it may require additional charging For charging the additional refrigerant follow the procedure in this chapter And then carry out the check operation 11 1 Before working About the refrigerant tank...

Page 19: ...oor and outside units are turned on H2P will be lit on and the compressor will not operate Check the LED display indicate as shown below In order to ensure uniform refrigerant distribution it may take...

Page 20: ...cedure During Automatic refrigerant charging operation the system will select charging mode cooling mode or heating mode by the tem perature condition as follows When charging in cooling mode the syst...

Page 21: ...ion valve and the valve are closed when charging is finished However the valve will opened when ather operation Check operation nomal operation etc If you leave the tank connected the refrigerant will...

Page 22: ...possible if the outdoor temperature is 75 F or higher Refer to the Operation manual If a knocking sound can be heard in the liquid compression of the com pressor stop the unit immediately and then ene...

Page 23: ...y to comply 1 Calculate the amount of refrigerant lb charged to each system sep arately NOTE Where a single refrigerant facility is divided into 2 entirely indepen dent refrigerant systems then use th...

Page 24: ...20 English NOTES...

Page 25: ...3P215731 2 EM07A038 0712 FS 1645 Wallace Drive Suite 110 Carrollton TX 75006 info daikinac com www daikinac com HT...

Reviews: