Operating instructions
18
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3
x
Operation
If the terminal function is activated, the
#X symbol is dis-
played in the header of the display as additional information on
the remote-controlled device, where "X" is the set device identifi-
cation of the remote-controlled device.
The displayed values and symbols are always accepted by the
selected device (e.g. mixer circuit T-HS of the EHS157068 mix
valve module with device identification 1).
In order to operate the local device, it must be activated again in
the selection list ([No selection] parameter).
Activating/deactivating terminal operation
Prerequisite: A valid terminal ID has been assigned to the
RoCon B1 control unit of the Daikin heat generator or to the
EHS157034 room station .
●
Set the rotary switch to the
"Remote Param"
position.
The "
Remote Param
" level is displayed.
●
Use the rotary button to select the [Bus - Scan] parameter.
●
Confirm the selection with a brief push of the rotary button.
The context menu is displayed.
●
Use the rotary button to select the [Bus - Scan] parameter
and confirm with "Yes".
Bus - Scan is carried out.
An overview of all the devices found is displayed (for an
example, see fig. 3-10).
●
Use the rotary button to select the device for which the
terminal function should be carried out.
●
Confirm the selection with a brief push of the rotary button.
The local control unit functions as a remote control for the
external device.
To
end
terminal operation
and to switch back to the control unit
for the operation of the assigned device, the [
No selection
]
pa-
rameter must be selected and confirmed
at the
"
Remote
Param
" level
.
Fig. 3-11 Example of the display for the remote-controlled mixer module
If the "n.a." message is displayed in the rotary switch
setting
, no valid terminal ID has been assigned to
the control unit until now.
If the "n.a." message is still displayed, it may be necessary to
update the device software in order to use the terminal function.
Contact the Daikin Service Team for this.
For setting the terminal ID of optionally connected de-
vices, see chap. 4.4 or the respective operating instruc-
tions that are supplied.
After an interim disconnection from the power supply,
the display always appears at the "
Remote Param
"
level, as shown in fig. 3-9.
To use the terminal function for connected devices, a repeat Bus
- Scan must be carried out.
Communication between the RoCon system components also
continues to function without Bus - Scan and previously made
settings remain active.
The terminal function is activated as shown in fig. 3-10, but after
confirmation of the "Bus - Scan" display, the [New scan?] pa-
rameter must be selected with the rotary button and confirmed
with "Yes".