Operating instructions
16
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3
x
Operation
Tab. 3-9 Factory setting of the permanent switching time programs
Temporary time programs
4
temporary time programs
are available for special situations,
which
make the
permanent time programs
or the currently set
operating mode
ineffective
for the duration of their validity.
The symbol of the temporary time program is displayed in the
header of the standard display for as long as the time program is
active.
1.
[Party]:
Immediate one-time extension
of the room
heating
a) If an automatic program is activated, the last valid
switching cycle is always extended. In the time prior to
switching cycle 1, the control is carried out according to
the target value in the [T-Room 1 Setpoint] parameter.
b) In all other operating modes, work is carried out according
to the set room target temperature of the first switching
cycle.
– The hot water generation is not affected.
– The time program runs for the set time period from activa-
tion.
2.
[Away]:
Immediate one-time setback
up to 6 hours.
– In setback mode, work is carried out according to the
room target temperature set in the [T-Absence] parameter
in the
"Set Temp Night"
rotary switch setting.
– The hot water generation is not affected.
– The time program runs for the set time period from activa-
tion.
3.
[Holiday]:
One-time calendar-controlled presence
.
– Control is carried out only according to the settings for
"Sunday" in the [HC Program 1].
– The hot water generation is only controlled according to
the settings for "Sunday" in the [DHW Program 1].
4.
[Vacation]:
One-time calendar-controlled setback
.
– In setback mode, work is carried out only according to the
room target temperature set in the [T-Absence] parameter
in the
"Set Temp Night"
rotary switch setting.
– Hot water generation according to the set target tempera-
tures and switching cycles in the [DHW Program 1] hot
water time program (see chap. 3.4.5).
– The calendar-controlled [Vacation] program is
not
started
if the [Standby] or [Manual operation] operating
mode is active at the set start date.
Switching cycle 1
Switching cycle 2
Switching cycle 3
Time period
On
Off
On
Off
On
Off
Room heating
Temperature setting
[T-Room 1 Setpoint]: 20 °C
[T-Room 2 Setpoint]: 20 °C
[T-Room 3 Setpoint]: 20 °C
[T-Reduced]: 10 °C
"HC Program 1"
Monday - Friday
06:00
22:00
- - : - -
- - : - -
- - : - -
- - : - -
Saturday, Sunday
07:00
23:00
- - : - -
- - : - -
- - : - -
- - : - -
"HC Program 2"
Monday - Friday
06:00
08:00
16:00
22:00
- - : - -
- - : - -
Saturday, Sunday
07:00
23:00
- - : - -
- - : - -
- - : - -
- - : - -
Domestic hot water generation
Temperature setting
[T-DHW Setpoint 1]: 60 °C
[T-DHW Setpoint 2]: 60 °C
[T-DHW Setpoint 3]: 60 °C
"DHW Program 1"
Monday - Sunday
05:00
21:00
- - : - -
- - : - -
- - : - -
- - : - -
"DHW Program 2"
Monday - Friday
05:00
21:00
- - : - -
- - : - -
- - : - -
- - : - -
Saturday, Sunday
06:00
22:00
- - : - -
- - : - -
- - : - -
- - : - -
"Circulation Time"
Monday - Friday
05:00
21:00
- - : - -
- - : - -
- - : - -
- - : - -
Saturday, Sunday
06:00
22:00
- - : - -
- - : - -
- - : - -
- - : - -
The following temporary time programs can be can-
celled at any time due to the manual changing of the
operating mode.