Operating instructions
14
Daikin RoCon
Daikin Control unit
008.1543999_00 – 03/2017 – EN
3
x
Operation
3.4.3 Temperature setting of daytime room
temperature
The target room temperatures during the day are determined for
the room heating in the
rotary switch setting.
●
Set the rotary switch to the
"Set Temp Day"
position.
An overview is displayed.
●
Select the temperature block to be set with the rotary button.
●
Confirm the selection with a brief push of the rotary button.
Settings are displayed.
●
Set the temperature.
●
Confirm the selection with a brief push of the rotary button.
The change has been accepted. Jump back to the previ-
ous display.
Detailed explanations and possible setting values for this rotary switch setting can
be found in chap. 6.5.
3.4.4 Temperature setting of setback mode
In the
rotary switch setting, the room target temperatures are
determined in the setback mode for the room heating.
●
Set the rotary switch to the
"Set Temp Night"
position.
An overview is displayed.
●
Select the parameter to be set with the rotary button.
●
Confirm the selection with a brief push of the rotary button.
– [T-Reduced]: Setting value for [Reducing] operating mode
or setback due to permanent time program.
– [T-Absence]: Setting value for temporary heating pro-
grams ("Away" and "Vacation").
Settings are displayed.
●
Set the temperature.
●
Confirm the selection with a brief push of the rotary button.
The change has been accepted. Jump back to the previ-
ous display.
Detailed explanations and possible setting values for this rotary switch setting can
be found in chap. 6.6.
3.4.5 Temperature setting of hot water generation
In the
rotary switch setting, the hot water target temperatures
are determined for the hot water generation of the respective time
programs.
●
Set the rotary switch to the
"DHW Set Temp"
position.
●
Select the temperature block to be set with the rotary button.
●
Confirm the selection with a brief push of the rotary button.
Settings are displayed.
●
Set the temperature.
●
Confirm the selection with a brief push of the rotary button.
The change has been accepted. Jump back to the previ-
ous display.
Detailed explanations and possible setting values for this rotary switch setting can
be found in chap. 6.7.
3.4.6 Unscheduled hot water generation
In the
rotary switch setting, the hot water can be manually
reheated to the preset target temperature in the [T-DHW Setpoint
1] parameter outside of a hot water time program. The heating up
is carried out with priority and independent of other heating pro-
grams.
●
Set the rotary switch to the
"DHW Reheating"
position.
An overview is displayed.
●
Select the parameter to be set with the rotary button.
– [1x Hot Water]: Activation of one-time hot water genera-
tion.
– [DHW Reloadtime]: Activation of time-limited hot water
generation.
●
Confirm the selection with a brief push of the rotary button.
●
Set the parameter.
●
Confirm the selection with a brief push of the rotary button.
The unscheduled hot water generation starts.
Possible setting values of this rotary switch setting can be found in chap. 6.3.
3.4.7 Switching time program
For comfortable and individual room and hot water temperature
control, different (but freely adjustable) time programs preset at
the factory can be selected.
The switching time programs control the assigned heating circuit,
the storage charging circuit as well as an optionally connected
circulation pump according to the specified switching times.
Setting
In the
rotary switch setting, the time intervals for the
heating circuit, integrated hot water generation and the optional
circulation pump are set.
●
Set the rotary switch to the
"Time Program"
position.
An overview is displayed.
●
Use the rotary button to select the time program to be set.
●
Confirm the selection with a brief push of the rotary button.
Settings are displayed.
●
Use the rotary button to select and change the value to be
adjusted.
●
Confirm the selection with a brief push of the rotary button.
Detailed explanations and possible setting values of this rotary switch setting can be
found in the chapter 6 "Parameter settings".
Permanent time programs
Time programs control the heating circuit temperatures or the op-
erating times of the circulation pump according to the specified
switching cycles for the connected heating circuits and the
storage charging circuit. The switching cycles are saved in time
blocks for which different target temperatures can be set.
In the switching cycles, the heating system is controlled differ-
ently according to day and setback mode.
The temperature settings for these time programs are carried out
via the target value settings
"Set Temp Day"
, "Set Temp
Night"
and "DHW Set Temp"
.
The last digits of the parameter designations (1 - 3)
within this rotary switch setting mark the affiliation to the
respective cycle of the time program.
The last digits of the parameter designations (1 - 3)
within this rotary switch setting mark the affiliation to the
respective cycle of the time program.
The two functions cannot be combined with each other.
After this temporary function has elapsed, the control
unit automatically jumps back to the previously active
operating mode. The rotary switch should therefore be brought
back into the
"Info"
position after the function has been ac-
tivated.