IM 1287-4 • REBEL APPLIED ROOFTOP 94 www.DaikinApplied.com
Unit Maintenance
Figure 148: Typical Rebel Wiring Diagram (continued)
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
DRAWN BY
CHECK BY
ACCESSED
PAGE DESC
DATE
DATE
SHEET
LOC
GO
OF
DRW
Control
PANEL
10
10
DIP SWITCHES: ON IS IN THE UP POSITION - THE
LAST MODULE IN LINE MUST HAVE DIP SWITCH 6 IN
THE ON POSITION
CP_GROUP
ACCESS_DATE
DRAWN_DATE
REV'D BY:
REV DESCRIPTION:
DATE:
DATE:
CHECK BY:
R01
REVISION
WorstCase001
MT-DEV-01.011
12-12-2019
MODBUS DEVICE ADDRESSES
COMM
24V
GND
B-
A+
DIRECT
CONNECTION
MODULE
MCB
24V
GND
B-
A+
EXP-D
24V
GND
B-
A+
B-
A+
24V
GND
1 OFF
SW1
2 OFF
3 ON
4 OFF
6
5 OFF
EXP-C
24V
GND
B-
A+
B-
A+
24V
GND
1 OFF
SW1
2 OFF
3 OFF
4 ON
6
5 ON
DIRECT
CONNECTION
EXP-H
24V
GND
B-
A+
B-
A+
24V
GND
1 OFF
SW1
2 ON
3 OFF
4 OFF
6
5 OFF
1015C
1016C
3
4
EXP-LV-OUT
EXP-LV-OUT
2
EXP-RE-IN
1
EXP-RE-IN
BK
WHT
4
EXP-RE-IN
3
EXP-RE-IN
2
EXP-RE-IN
1
EXP-RE-IN
1019A
1020A
TBRE
24V
TBRE
GND
EXP-I
24V
GND
B-
A+
B-
A+
24V
GND
1 OFF
SW1
2 ON
3 OFF
4 OFF
6
5 ON
DIRECT
CONNECTION
DIRECT
CONNECTION
EXP-A
24V
GND
B-
A+
B-
A+
24V
GND
1 OFF
SW1
2 OFF
3 OFF
4 OFF
6
5 ON
1007C
1008C
1009C
1010C
1
2
3
4
EXP-A-OUT
EXP-A-OUT
EXP-A-OUT
EXP-A-OUT
4
EXP-C-IN
3
EXP-C-IN
2
EXP-C-IN
1
EXP-C-IN
RD
BK
WHT
GRN
4
EXP-C-IN
3
EXP-C-IN
2
EXP-C-IN
1
EXP-C-IN
NOTE: SPLICE SHIELDS TOGETHER BUT ONLY TERMINATE ON MCB
IDF1
2
1
IDF1 : 81
WH
BK
DRN
1029A
1030A
1031A
IDF2
2
1
IDF2 : 82
WH
BK
DRN
1029B
1030B
1031B
MCB
A1+
B1-
MCB : 01
WH
BK
DRN
1029C
1030C
1031C
PMON
+
-
PMON : 05
WH
BK
DRN
1029D
1030D
1031D
OF11-VFD
68
69
OF11-VFD
: 51
WH
BK
DRN
1033A
1034A
1035A
OF21-VFD
68
69
TO
NEXT
DEVICE
FROM
PREVIOUS
DEVICE
OF21-VFD
: 52
WH
BK
DRN
1033B
1034B
1035B
SF1
1
2
SF1 : 11
WH
BK
DRN
1033C
1034C
1035C
SF2
1
2
SF2 : 12
WH
BK
DRN
1033D
1034D
1035D
SF3
1
2
SF3 : 13
WH
BK
DRN
1037A
1038A
1039A
SF4
1
2
FROM
PREVIOUS
DEVICE
TO
NEXT
DEVICE
SF4 : 14
WH
BK
DRN
1037B
1038B
1039B
ERW-VFD
68
69
ERW-VFD
: 41
WH
BK
DRN
1037C
1038C
1039C
EF1
1
2
EF1 : 21
WH
BK
DRN
1037D
1038D
1039D
EF2
1
2
EF2 : 22
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
Summary of Contents for Rebel Applied DPSA
Page 147: ...Figure 181 600 MBH 5 1 Modulation 400 MBH and 600 MBH 10 1 Modulation ...