Unit Maintenance
www.DaikinApplied.com 89
IM 1287-4 • REBEL APPLIED ROOFTOP
Figure 143: Typical Rebel Wiring Diagram (continued)
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
DRAWN BY
CHECK BY
ACCESSED
PAGE DESC
DATE
DATE
SHEET
LOC
GO
OF
DRW
Control
PANEL
5
10
CP_GROUP
ACCESS_DATE
DRAWN_DATE
REV'D BY:
REV DESCRIPTION:
DATE:
DATE:
CHECK BY:
R01
REVISION
WorstCase001
MT-DEV-01.011
12-12-2019
SEE PAGE 10 FOR MODBUS
CONNECTIONS
ZNT01
COOLING &
HEATING
SET POINT
OVERRIDE SEN1/S
GDN/C
SET/P
TBLV2
TBLV2
210
212
WALLSTAT
SPACE
TEMP
SENSOR 1
ZONE
SETPOINT
521A
523A
TBLV2
236
DSP
525A
526A
1
3
1
2
SAF DUCT STATIC
PRESSURE
BSP
528A
529A
3
2
2
1
BUILDING STATIC
PRESSURE
SFAF
531A
532A
3
1
1
2
SUPPLY AIR FAN
FLOW INPUT
TBLV4
+24V
WH
BK
SHD
DAT
DISCHARGE AIR
TEMP
TBLV1
540F
540E
DUCT HI LIMIT
DHL
120V
1
3
544A
200
TBLV2
201
TBLV2
TBLV4
24V-B
544B
TIME CLOCK OR
TENNANT OVERRIDE
1
2
TBLV2
240
LOCAL / REMOTE
STATUS OUTPUT
507E
TBLV2
240C
506E
536F
TBLV2
215
TBLV2
216
TBLV2
217
TBLV4
N24-B
ALARM OUTPUT
536E
538E
AUX OUTPUT
24V-B
TBLV4
534E
24VAC 75mA MAX
24VAC 75mA MAX
WH
BK
SHD
TBLV4
M
LCT
LEAVING COIL TEMP
TBLV2
214
514A
CO2 / EXT OA RESET
548A
297
TBLV2
297A
TBLV2
TBLV4
24V-B
548B
PASSIVE VENTILATION INPUT
1
2
N24-A
566G
TBLV1
N24-A
R-ISO
RISO
540A
ISOLATION DAMPER
OPEN
24V-A
TBLV1
DAMP
TBLV1
DAMP2
TBLV1
542A
11 14
566F
A2
A1
RHV1
WHT
BLK
RED
GRN
538C
TBLV4
M
202
TBLV2
205
TBLV2
MJ
203
TBLV2
204
TBLV2
206
TBLV2
FOR FIELD INTERLOCKS,
REMOVE JUMPER AND
CONNECT CONTACTS HERE
EMERGENCY OFF CIRCUIT
536B
536A
RTN-SD
6
16
N24
566D
567D
SAID
TBLV1
N24-A
TBLV1
24V-A
566C
567C
4
1
3
2
SUP-SD
6
16
536C
536D
T T
OUTDOOR AIR
TEMP/HUMIDITY
MODULE (SHIELD
GROUND SHOWN
ON OARH)
OATRH
TBLV4
M
+
-
OUTDOOR AIR REL.
HUMIDITY SENSOROATRH
GRN
RD
SHD
504A
505A
516A
517A
CL
BK
SHD
M3-
M4+
M4-
M3+
COM
M2+
M1-
M1+
M2-
COM
X9
G0
M
+5V
+24V
C1
DO1B
MCB
X4
X3
C2
DO2B
G
DO3
DO4
DO6
DO8
DO9
C9-10
DO10
X10
M
X11
X1
M
X2
M
+5V
+24V
X8
X7
X5
M
X6
M
DI1
M
DI2
DI3
R3-4
DI4
DI5
R5-6
DI6
TBLV4
+24V
527A
N24-B
TBLV4
M
24V-B
503E
502E
TBLV4
TBLV4
503C
DO1A
DO2A
C3
C4
DO5
C5-6
DO7
C7-8
REF1
B1-
A1+
CE-
CE+
A2+
B2-
REF2
N24-B
TBLV4
546A
541E
N120
TBLV1
TBLV2
236
513A
120V
TBLV1
542E
RAID
TBLV1
N24-A
567B
566B
24V-A
TBLV1
566A
567A
2
3
4
1
RTN-SD
RETURN AIR
SMOKE DETECTOR
TBLV2
296B
563A
564A
18
10
9
TBLV1
24V-A
TBLV1
N24-A
TBLV2
296A
8
RETURN AIR
SMOKE DETECTOR
STATUS TO FIELD
562A
561A
COS
538B
538A
2
1
N120
TBLV1
120V
TBLV1
RHBV1
N
H
511E
512E
512F
REHEAT BLEED
VALVE 1
SUP-SD
SUPPLY AIR
SMOKE DETECTOR
TBLV2
296D
563E
564E
18
10
9
TBLV1
24V-A
TBLV1
N24-A
TBLV2
296C
8
SUPPLY AIR
SMOKE DETECTOR
STATUS TO FIELD
562E
561E
RSP1A
11 12
534A
534B
21 24
535E
535F
RSP1A
24V-B
TBLV4
11 14
539E
539F
RSP1B
24V-B
TBLV4
Summary of Contents for Rebel Applied DPSA
Page 147: ...Figure 181 600 MBH 5 1 Modulation 400 MBH and 600 MBH 10 1 Modulation ...
Page 160: ......
Page 161: ......