Unit Maintenance
www.DaikinApplied.com 93
IM 1287-4 • REBEL APPLIED ROOFTOP
Figure 147: Typical Rebel Wiring Diagram (continued)
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
DRAWN BY
CHECK BY
ACCESSED
PAGE DESC
DATE
DATE
SHEET
LOC
GO
OF
DRW
Control
PANEL
9
10
CP_GROUP
ACCESS_DATE
DRAWN_DATE
REV'D BY:
REV DESCRIPTION:
DATE:
DATE:
CHECK BY:
R01
REVISION
WorstCase001
MT-DEV-01.011
12-12-2019
DO1
EXP-H
C1
DO2
C2
DO3
C3-4
DO4
DI1
R1
DO5
C5-6
DO6
+5V
+24V
X4
X3
X1
M
X2
M
+5V
+24V
X8
X7
X5
M
X6
M
+5V
+24V
N120
TBRE
927D
120V
TBRE
OADSW2
ES2
TBRE
962D
24V-E
TBRE
OADSW1
ES1
TBRE
962B
4
4
3
3
962A
962C
TBRE
N24-E
962F
ROAD
962E
A2
A1
ROAD
11 14
924D
924E
+5V
DO1
EXP-I
X4
C1
X3
DO2
C2
DO3
C3-4
DO4
X1
M
X2
M
+24V
X8
X7
X5
M
X6
DI1
R1
DO5
C5-6
DO6
M
TBRE
+24V-I
949C
+24V
+5V
WH
BK
SHD
ERLT
ERW LEAVING
AIR TEMP
WH
BK
SHD
ERET
ERW EXHAUST
AIR TEMP
WH
BK
SHD
-
+
RD
SHD
GRN
T T
RETURN AIR TEMP
HUMIDITY MODULE
RATRH
RETURN AIR TEMP
HUMIDITY SENSOR
RETURN AIR HUMIDITY
SEE LINE 926
RETURN AIR TEMP SEE
LINE 908
RATRH
909B
908B
927B
926B
OAFM
L2
L1
1
COM
TBRE
24V-E
TBRE
N24-E
EBTRON FLOW TRANSMITTER
PROBE
902C
901C
901A
902A
RETURN
AIR
DAMPER
8
2
1
RD
BK
SHD
WH
TBRE
N24-E
TBRE
24V-E
3
2
1
3
2
1
RAD
919B
918B
917B
OUTDOOR
AIR
DAMPER
8
1
2
WH
BK
SHD
RD
TBRE
24V-E
TBRE
N24-E
3
1
2
3
1
2
OAD
916B
915B
914B
PREHEAT SCR
CONTROL
EHEAT2
953B
952B
2
1
2
1
TBRE
+24V-I
EXSP
1
3
1
2
EXHAUST AIR
PLENUM STATIC
PRESSURE
941B
940B
940C
EXHAUST
AIR
DAMPER
8
1
2
WH
BK
SHD
RD
TBRE
24V-E
TBRE
N24-E
3
1
2
3
1
2
EAD
937B
936B
938B
12
RSP4B
938E
14
RSP4B 937D TBRE
+24DC
RSP4B
11
PTMF
1
3
1
2
MAIN
FILTER
PRESS.
XDCR
TBRE
+24V-I
945B
944B
PTERF
1
3
1
2
ERW
FILTER
PRESS.
XDCR
949B
948B
ERBD
24V-E
TBRE
1
1
938D
942D
938E
2
2
N24-E
TBRE
BYPASS
DAMPER
904C
EXP-H
M
956B
955B
TBRE
+24V-I
EAFM
1
3
1
2
EXHAUST
FAN
FLOW
966B
964B
120V
120COM
24+
24COM
24V
120V
XF2E
964D
966D
TBRE
N24-E
TBRE
N120
TBRE
24V-E
TBRE
120V
TBRE
N24-E
VA:75
TBHV
120V
TBHV
N120
964A
964E
24V-E
TBRE
901D
EXHAUST
AIR
DAMPER
1
2
1
2
1
2
EAD
TBRE
N24-E
904E
903D
12
RSP4B
RSP4B
11
TBRE
24V-E
903F
14
RSP4B
902E
12
RSP2B
14
RSP2B 915F
916E
TBRE
X5-H
916C
TBRE
+24DC
RSP2B
11
L/+
N/-
+
-
TBRE
N12DC
966E
TBRE
N120
966F
TBRE
+12DC
965F
965E
TBRE
120V
DCPS
RSP4A
24V-E
TBRE
A1
A2
RSP2B
A1
A2
RSP4B
RSP2A
24V-E
TBRE
TBRE
N24-E
960C
TBRE
N24-E
959C
21 24
21 24
959B
960B
960A
959A