background image

4

155

11

o/

45

40

90

5

80

14

55

195

30 or more

30 or more

4-M8~M10

Hanging bolt

(Service space)

(Service space)

1

B

127

8

10

17

18

(Hanging

    position)

(Hanging position)

A

16

210

36

170

58

192

85

160

105

102

142

90

185

260

4

170

7

225

Drain pipe connection VP20

6

275

Brand name plate

The Front

(Note.2)

80

275

105

(For left piping)

300

3

2

5

80

6

(Required space)

Obstacle

680

Floor side

5

155

55

(Required space)

300 or more

13

For height installation

From the floor side 2500 or more

105

15

(Required space)

135

5

Position : Hole of wall for taking out in piping back

(View from the front)

65

50

135

145

9

60

65

12

40

60

60

115

Position slit hole for taking out in piping back

(View from the front)

DIMENSIONS

(Unit: mm)

21

22

CEILING SUSPENDED TYPE

236

3×P.150=450

16

260

16

151

704

10

688

150

900

127

(All Around)

219

10

12-M4 Holes

52

674

5

7

4

6

664

170

110

684

260

(All Around)

1

228

3×P150=450

500

10-M4 Holes

164

2

29

50

134

107

10 or more

300 or more

317

3

704

500

167

580

151

126

8

271

(Suspension bolt pinch)

3

55

(Suspension bolt pinch)

755

137

900

Service space

DUCT CONNECTION  LOW STATIC PRESSURE TYPE

A

B

[FHNQ13/18/21/26/30/36/42/48MV1]

[FDBNQ09/13/18MV1]

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18

Air discharge grille
Air suction grille
Air filter
Gas pipe connection
Liquid pipe connection
Drain pipe connection
Earth terminal (Inside the electric components box)
Suspension bracket
Backward pipe and wiring connection opening lid
Upward pipe and wiring connection opening lid
Right side pipe connection
Left back drain pipe connection
Left side drain pipe connection
Right side drain pipe connection
Hole of wall for taking out in pipe back
Upward drain pipe connection
Upward gas pipe connection
Upward liquid pipe connection

Notes:

1

Location of unit's Name plate : Bottom of fan housing inside the suction grille.

2

In case of using wireless remote controller, this position will be a signal receiver. 

 Refer to the drawing of wireless remote controller in detail.

3

The remote control code is the standard <about 3m outside the machine> attached.

(0.5mm

2

x

2 wicks O.D.  5.4)(It is not attached to VRV.)

Note: 

1

Location of unit's Name Plate: Chamber cap

Liquid pipe connection 
Gas pipe connection
Drain pipe connection
Ground terminal 

1
2
3
4

Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket

5
6
7
8

920

960

1120 1160

1120 1160

FHNQ13MV1

FHNQ18MV1

FHNQ21MV1

1360 1400

FHNQ26MV1

1360 1400

FHNQ30MV1

1550 1590

FHNQ36MV1

1550 1590

FHNQ42MV1

1550 1590

FHNQ48MV1

CEILING MOUNTED CASSETTE TYPE

Notes:

1

Sticking location for manufacture's label

 manufacture's label for indoor unit:
 Suction grille inner side's electric components box's lid surface
 manufacture's label for decoration panel :
 Decoration panel's corner decoration cover inner surface

2

In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller 
in detail.

3

When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit 
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.

4

Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less 
between the indoor unit and the ceiling opening so that

 the panel overlap allowance can be ensured.

5

Please do not place the thing been damp and troubled under an indoor unit.

 When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.

[FCNQ13-48MV1]

[FCNQ13-48MV1]

[FCNQ13-26MV1]

[FCNQ13-26MV1]

[FCNQ13-26MV1]

[FCNQ13-26MV1]

[FCNQ30-48MV1]

[FCNQ30-48MV1]

[FCNQ30-48MV1]

[FCNQ30-48MV1]

7

6

950

8

950

Pipe Connection

Side

Drain Connection

Side

Note 2

A arrow view

9

C

B

420

710(Hanging bolt pitch)

420

860~910(Ceiling opening space) (Note 4)

860~910(Ceiling opening space) (Note 4)

780(Hanging bolt pitch)

95

330

165

Connection position

of branch duct

160

20

16-M4 Prepared hole

50

350

124

80

175

125

2

(square-shaped type)

4

1

157

246

55

4-M8~M10

2x100=200 80

124

10

Hanging bolt

Connection position

of branch duct

C/L

110

(round shape type)

840

55

280

256

40

Adjustable(0~675)

340

850

Connection position

of branch duct

1500 or more

Connection position

of branch duct

20-M4 Prepared hole

60

From the floor side 2500 or more

130

124

2x100=200

35 or less 

(Note 4)

55

A

150

840

55

160

157

256

105

(square-shaped type)

For height installation

42

(required space)

(Note 4)

95

3

85

124

35 or less

5

(round shape type)

64

350

81

110

50

124

81

2x100=200

350

Connection position

of branch duct

160

16-M4 Hole

B arrow view

(round shape type)

110

C/L

124

85

157

(square-shaped type)

95

Connection position

of branch duct

80

157

213

95

160

Connection position

of fresh air intake kit

(square-shaped type)

C arrow view

(knock

  hole)

90

(round shape type)

124

183

109

25

C/L

124

80

2x100=200

(direct installation type)

ø100

20-M4

Prepared hole

Connection position

of branch duct

Connection position

of branch duct

90

350

157

93

2x100=200

85

67

Connection position

of branch duct

C/L

(round shape type)

160

Connection position

of branch duct

16-M4 Hole

167

(square-shaped type)

B arrow view

160

95

81

350

29

213

29

350

80

160

ø100

Connection position

of fresh air intake kit

C/L

157

90

(direct installation type)

67

(knock

  hole)

Connection position

of branch duct

C arrow view

Connection position

of branch duct

2x100=200

(round shape type)

(square-shaped type)

196

93

90

80

25

95

160

20-M4

Prepared hole

167

280

50

288

80

167

95

157

340

840

165

10

4

Hanging bolt

1

175

55

4-M8~M10

Connection position

of branch duct
(round shape type)

Connection position

of branch duct

2

40

80

160

2x100=200

125

(square-shaped type)

C/L

298

20

350

850

Adjustable(0~675)

55

29

330

160

16-M4 Prepared hole

160

1500 or more

81

93

157

130

Connection position

of branch duct

160

2x100=200

A

55

(square-shaped type)

From the floor side 2500 or more

(Note 4)

67

105

For height installation

85

150

(required space)

350

42

29

64

(round shape type)

27-M4 Prepared hole

60

35 or less 
(Note 4)

35 or less

3

Connection position

of branch duct

256

160

5

95

50

840

55

167

The necessary space is 500mm or more when the 

air-outlet is blocked with the accessory.

Moreover when the corner areas are blocked 

(both right and left of the blocked air outlet), 

the necessary space is 200mm or more.

1500mm or more

200mm or more

1500mm or more

1500mm

  or more

1500mm

  or more

200mm

or more

Required space

300 

or less

Liquid pipe connection
Gas pipe connection
Drain pipe connection
Power-source wiring and a unit 
wiring connection
Connection wiring/remote control 
wiring connection
Air-outlet
Suction grille
Corner decoration cover
Drain hose (accessory)

1
2
3
4

5

6
7
8
9

Summary of Contents for PCSMT1420A

Page 1: ...ire or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and acces...

Page 2: ...YPE Round Flow Series Pair FCNQ18MV1 RNQ13MV1 FCNQ13MV1 FCNQ21MV1 FCNQ26MV1 RNQ26MY1 30 RNQ30MV1 FCNQ30MV1 RNQ30MY1 36 RNQ36MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1 FCNQ36MV1 RNQ36MY1 42 RNQ42MY1 FCNQ42MV1 48 2...

Page 3: ...still obtain the same feeling temperature and comfort Operation sound increases when using 2 way or 3 way flow 1 4 6 Cleanliness Comfort Work Servicing Control features Others Options Features Access...

Page 4: ...t higher owing to ambient conditions Note Air direction is set to the standard position when the unit is shipped from the factory The position can be changed from the remote controller Panel size is s...

Page 5: ...ide as was formerly the case The unit fits more snugly into tight spaces Flexible installation Uniform height and depth Compact design for small capacity models to meet tighter dimensional constraints...

Page 6: ...e sensors Remote controller 2 2 2 2 3 Setpoint range set Weekly schedule timer Setpoint auto reset Off timer programmed On Off timer 1 6 Comfort Work Servicing Control features Others Features 1 Appli...

Page 7: ...s DCS301BA61 Option Schedule timer Unified control of weekly schedule for up to 1 024 indoor units DST301BA61 Option Schedule timer sets on off time in 1 minute units to be executed twice a day for a...

Page 8: ...set as holiday 3 independent schedules can be set e g summer winter mid season Display is available in 11 languages Dot matrix display Backlight display Convenience Weekly schedule Multilingual displ...

Page 9: ...te Others To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution coated Anti corrosion treated heat exchangers with special acryl pretreatment are used for...

Page 10: ...42 000 4 51 2 73 48 FHNQ48MV1 RNQ42MY1 RNQ48MY1 14 1 48 000 5 51 2 56 42 44 24 26 1 483 1 553 847 918 3 Phase 380 415 V 50 Hz Outdoor unit Outdoor unit Cooling capacity1 2 kW Y1 V1 Y1 V1 kW Power cons...

Page 11: ...air intake kit Chamber type 1 2 High efficiency filter2 High humidity operation kit Ultra long life filter2 19 20 Indoor unit Indoor unit OPTIONS Outdoor unit Kit name RNQ18MV1 RNQ21MV1 RNQ09MV1 RNQ13...

Page 12: ...e ceiling opening keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured 5 Please do not place the thing been damp and tr...

Page 13: ...pension bracket 5 6 7 8 300 or more 7 P150 1050 263 151 20 M4 Holes 51 1350 1137 16 1121 8 10 305 All Around 16 150 74 280 1153 7 5 6 4 1114 1134 1 29 50 123 18 M4 Holes 152 206 274 175 2 305 All Arou...

Page 14: ...IMENSIONS Unit mm Gas pipe connection Liquid pipe connection Service port Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection 1 2 3 4 5...

Page 15: ...sed body embedded cord Conduit CONTROL BOX Through hole Size Specifications of cord 0 75 1 25 mm2 Total length 500 m Type Vinyl cord with sheath or cable Insulated thickness 1 mm or more Note 1 Remote...

Page 16: ...29 30 MEMO...

Reviews: