OUTDOOR UNIT // RNQ30MV1, RNQ30MY1

OUTDOOR UNIT // RNQ36MV1, RNQ36/42/48MY1

OUTDOOR UNIT // RNQ18/21MV1

OUTDOOR UNIT // RNQ26MV1, RNQ26MY1

25

26

30

620

91

160

30

30

Hole for anchor bolt 4-M12

55

(345

355)

37

320

160

350

38

145

5

84

53

7

95

6

80

55

19

416

68

161

595

61

16

260

262

36

279

285

8

90

16

5

95

13

53

5

55

223

6

7

67

52

339

89

95

19

2

5

3

6

4

990

142

340

60

89

1

940

7

53

96

89

58

1

16

24

54

350

(345~355)

3

71

45

145

41

7

6

95

620

60

5

95

4

89

320

8

84

48

70

410

54

1345

30

80

30

102

140

55

19

900

5

5

376

435

19

140

6

61

117

142

2

191

7

30

16

Hole for anchor 
bolt 4-M12

5

6

7

53

67

55

95

13

223

52

1
2
3
4
5
6
7
8

Gas pipe connection
Liquid pipe connection
Service port (in the unit)
Grounding terminal
Refrigerant piping intake
Power supply wiring intake
Control wiring intake
Drain pipe connection

DIMENSIONS

(Unit: mm)

Gas pipe connection
Liquid pipe connection
Service port
Grounding terminal
Refrigerant piping intake
Power supply wiring intake
Control wiring intake
Drain pipe connection

1

2

3

4

5

6

7

8

50

50

300

300

50

300

150

50

100

20

845

573.5

20

131

7

342

300

78

326

300

Drain outlet

I.D.   18 hose for connection

4-Hole for anchor bolts

 (M8 or M10) 

595

Brand name label

Wiring inlet

Name plate

105

144

60

Earth terminal 

in switch box

Gas stop valve

(   15.9CuT for RNQ21MV1)
(   12.7CuT for RNQ18MV1)

Liquid stop valve

(   6.4CuT)

Service port

Wall height on air outlet side 

=less than 1000

Minimum  space  for  air  passage

325

36

350

78

580

330

825

25

10

300

2

124

Drain outlet

I.D.  15.9 hose for connection

4-Hole for anchor bolts

 (M8 or M10) 

735

Brand name label

Wiring inlet

Name plate

30

18

64

155
160

89

Earth terminal 

in switch box

Gas stop valve

(   15.9CuT)

Liquid stop valve

(   9.5CuT)

Service port

350

100

50

100

100

50

350

50

350

Wall height on air outlet side 

=less than 1200

Minimum  space  for  air  passage

Summary of Contents for PCSMT1420A

Page 1: ...ire or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and acces...

Page 2: ...YPE Round Flow Series Pair FCNQ18MV1 RNQ13MV1 FCNQ13MV1 FCNQ21MV1 FCNQ26MV1 RNQ26MY1 30 RNQ30MV1 FCNQ30MV1 RNQ30MY1 36 RNQ36MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1 FCNQ36MV1 RNQ36MY1 42 RNQ42MY1 FCNQ42MV1 48 2...

Page 3: ...still obtain the same feeling temperature and comfort Operation sound increases when using 2 way or 3 way flow 1 4 6 Cleanliness Comfort Work Servicing Control features Others Options Features Access...

Page 4: ...t higher owing to ambient conditions Note Air direction is set to the standard position when the unit is shipped from the factory The position can be changed from the remote controller Panel size is s...

Page 5: ...ide as was formerly the case The unit fits more snugly into tight spaces Flexible installation Uniform height and depth Compact design for small capacity models to meet tighter dimensional constraints...

Page 6: ...e sensors Remote controller 2 2 2 2 3 Setpoint range set Weekly schedule timer Setpoint auto reset Off timer programmed On Off timer 1 6 Comfort Work Servicing Control features Others Features 1 Appli...

Page 7: ...s DCS301BA61 Option Schedule timer Unified control of weekly schedule for up to 1 024 indoor units DST301BA61 Option Schedule timer sets on off time in 1 minute units to be executed twice a day for a...

Page 8: ...set as holiday 3 independent schedules can be set e g summer winter mid season Display is available in 11 languages Dot matrix display Backlight display Convenience Weekly schedule Multilingual displ...

Page 9: ...te Others To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution coated Anti corrosion treated heat exchangers with special acryl pretreatment are used for...

Page 10: ...42 000 4 51 2 73 48 FHNQ48MV1 RNQ42MY1 RNQ48MY1 14 1 48 000 5 51 2 56 42 44 24 26 1 483 1 553 847 918 3 Phase 380 415 V 50 Hz Outdoor unit Outdoor unit Cooling capacity1 2 kW Y1 V1 Y1 V1 kW Power cons...

Page 11: ...air intake kit Chamber type 1 2 High efficiency filter2 High humidity operation kit Ultra long life filter2 19 20 Indoor unit Indoor unit OPTIONS Outdoor unit Kit name RNQ18MV1 RNQ21MV1 RNQ09MV1 RNQ13...

Page 12: ...e ceiling opening keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured 5 Please do not place the thing been damp and tr...

Page 13: ...pension bracket 5 6 7 8 300 or more 7 P150 1050 263 151 20 M4 Holes 51 1350 1137 16 1121 8 10 305 All Around 16 150 74 280 1153 7 5 6 4 1114 1134 1 29 50 123 18 M4 Holes 152 206 274 175 2 305 All Arou...

Page 14: ...IMENSIONS Unit mm Gas pipe connection Liquid pipe connection Service port Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection 1 2 3 4 5...

Page 15: ...sed body embedded cord Conduit CONTROL BOX Through hole Size Specifications of cord 0 75 1 25 mm2 Total length 500 m Type Vinyl cord with sheath or cable Insulated thickness 1 mm or more Note 1 Remote...

Page 16: ...29 30 MEMO...

Reviews: