background image

LCD REMOTE CONTROLLER

Optional accessory

Enables temperature sensing closer to target 
area for improved comfort. (When using remote 
control from another room, temperature-sensor in 
indoor unit's air inlet must be selected.)

Facilitates maintenance and repair

All initial settings can be set from the remote 
controller. After interior construction is complete, 
ceiling mounted cassette type can be remotely 
set without having to use stepladder access for 
manual setting.

Setting contents: High ceiling use, air direction, filter type, address 

for centralised control (group control address is set automatically).

Remote controller is equipped with model name 
and failure display functions. This facilitates 
service in the unlikely event of a malfunction.

Ceiling mounted cassette type 
shares common control with Heat 
Reclaim Ventilator and the other 
Daikin air-conditioning units, thus 
simplifying interlocking operations.

Easily adaptable to large-scale, high-function, 
centralised remote control systems.
Installing and connecting control wiring between 
SkyAir and other Daikin air-conditioning 
equipment is easy. 

LCD panel shows operating status in letters, numbers, and motion.

Airflow / swing display

Displays auto-swing operating status and setting position of air discharge angle.

Preset temperature / operation mode display

Displays preset room temperature and operating status (fan, dry, cool).

Programming time display

Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows 
when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.

Self-diagnosis function

Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.

CEILING MOUNTED CASSETTE TYPE

CEILING SUSPENDED TYPE

DUCT CONNECTION LOW STATIC PRESSURE TYPE

BRC7NU66

BRC7F633F

BRC4C64

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

BRC4C64

Wired remote controller has 
built-in temperature-sensor

 

(Applies to wired remote controllers 

(BRC1C61/1E62)

)

(Applies to wired remote controller 

(BRC1E62)

)

13

14

Clear Display

Navigation Remote Controller
(Wired Remote Controller BRC1E62)

- 5 actions per day can be scheduled for each day 
  of the week.
- The holiday function will disable schedule timer 
  for the days that have been set as holiday.
- 3 independent schedules can be set. 

  (e.g. summer, winter, mid-season)

Display is available in 11 
languages.

Dot matrix display

Backlight 
display

Convenience

Weekly schedule

Multilingual display

Easy-to-read LCD remote controller allows various system     control configurations and can control multiple indoor units.

 Remote controller options are shown on the page introducing each indoor unit model.

NEW

(English, German, French, Spanish, 

Italian, Portuguese, Greek, Dutch, 

Russian, Turkish, and Polish).

NEW

A combination of fine dots 
enables various icons.
Large text display is easy to 
see.

This simple, modern designed remote controller with fresh 
white colour matches your interior design. Operation is 
much easier and smoother, just follow the indications on 
the navigation remote controller.

Energy saving

NEW

- Sets and saves setting for an increment of time that automatically turns off air 
  conditioner after a preset period of time for each time operation starts.
- Period can be preset from 30  to 180 minutes in10-minute increments.

Off timer (programmed)

Setpoint range set

NEW

Setpoint auto reset

Restaurant sample

Restaurant opened

Temperature is set to 27ºC

27

°C

- Saves energy by limiting the 

min. and max. set temperature.

- Avoids excessive heating or 

cooling. 

- This function is convenient when 

the remote controller is installed 
at a place where any number of  
people may operate it.  

- Even if the set temperature is changed, it returns to the preset temperature 

after apreset period of time.

- Period selectable from 30min/60min/90min/120min.

Full tables at lunchtime

Then is lowered to 24ºC for 
crowded room

24

°C

After 30 minutes*

Automatically returns to preset 
temperature (27ºC)

*Setting possible for after 30, 60, 90, and 120 
  minutes. 

Returns to

27

°C

automatically

Signal receiver unit 
(For ceiling mounted 
 cassette type)

Wireless remote controller for each indoor unit type

LCD wireless remote controller

Note: The signal receiver unit shown in the 

photograph is for mounting inside 
the decoration panel of the ceiling 
mounted cassette type. 

Wireless remote 

controller

BRC7F633F

The wireless remote controller is 
supplied in a set with a signal 
receiver.

Signal receiver unit is contained 
inside decoration panel or indoor 
unit.

Shape of signal receiver unit 
differs according to the indoor 
unit.

The rubber switch and the 
oil-resistant plastic casing are 
adopted for durability.

Only 17 mm thick. Can be 
installed  either recessed or 
exposed. 

Easy to read because of large LCD screen.

Wired LCD remote controller

BRC1C61

Summary of Contents for PCSMT1420A

Page 1: ...ire or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and acces...

Page 2: ...YPE Round Flow Series Pair FCNQ18MV1 RNQ13MV1 FCNQ13MV1 FCNQ21MV1 FCNQ26MV1 RNQ26MY1 30 RNQ30MV1 FCNQ30MV1 RNQ30MY1 36 RNQ36MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1 FCNQ36MV1 RNQ36MY1 42 RNQ42MY1 FCNQ42MV1 48 2...

Page 3: ...still obtain the same feeling temperature and comfort Operation sound increases when using 2 way or 3 way flow 1 4 6 Cleanliness Comfort Work Servicing Control features Others Options Features Access...

Page 4: ...t higher owing to ambient conditions Note Air direction is set to the standard position when the unit is shipped from the factory The position can be changed from the remote controller Panel size is s...

Page 5: ...ide as was formerly the case The unit fits more snugly into tight spaces Flexible installation Uniform height and depth Compact design for small capacity models to meet tighter dimensional constraints...

Page 6: ...e sensors Remote controller 2 2 2 2 3 Setpoint range set Weekly schedule timer Setpoint auto reset Off timer programmed On Off timer 1 6 Comfort Work Servicing Control features Others Features 1 Appli...

Page 7: ...s DCS301BA61 Option Schedule timer Unified control of weekly schedule for up to 1 024 indoor units DST301BA61 Option Schedule timer sets on off time in 1 minute units to be executed twice a day for a...

Page 8: ...set as holiday 3 independent schedules can be set e g summer winter mid season Display is available in 11 languages Dot matrix display Backlight display Convenience Weekly schedule Multilingual displ...

Page 9: ...te Others To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution coated Anti corrosion treated heat exchangers with special acryl pretreatment are used for...

Page 10: ...42 000 4 51 2 73 48 FHNQ48MV1 RNQ42MY1 RNQ48MY1 14 1 48 000 5 51 2 56 42 44 24 26 1 483 1 553 847 918 3 Phase 380 415 V 50 Hz Outdoor unit Outdoor unit Cooling capacity1 2 kW Y1 V1 Y1 V1 kW Power cons...

Page 11: ...air intake kit Chamber type 1 2 High efficiency filter2 High humidity operation kit Ultra long life filter2 19 20 Indoor unit Indoor unit OPTIONS Outdoor unit Kit name RNQ18MV1 RNQ21MV1 RNQ09MV1 RNQ13...

Page 12: ...e ceiling opening keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured 5 Please do not place the thing been damp and tr...

Page 13: ...pension bracket 5 6 7 8 300 or more 7 P150 1050 263 151 20 M4 Holes 51 1350 1137 16 1121 8 10 305 All Around 16 150 74 280 1153 7 5 6 4 1114 1134 1 29 50 123 18 M4 Holes 152 206 274 175 2 305 All Arou...

Page 14: ...IMENSIONS Unit mm Gas pipe connection Liquid pipe connection Service port Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection 1 2 3 4 5...

Page 15: ...sed body embedded cord Conduit CONTROL BOX Through hole Size Specifications of cord 0 75 1 25 mm2 Total length 500 m Type Vinyl cord with sheath or cable Insulated thickness 1 mm or more Note 1 Remote...

Page 16: ...29 30 MEMO...