Quiet operation
Quiet operation
9
10
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Freedom of layout
BRC4C64
A signal receiver must be added to the indoor unit.
Wireless remote controller
and signal receiver unit
are sold as a set.
Wireless LCD remote controller
Wired LCD remote controller
BRC1C61
Accessory required for indoor unit
Option
Signal receiver unit
(Separate type)
Switchable fan speed: High/Low
Drain pipe connection can be done inside
the unit. Refrigerant and drain pipe outlets
are at the same opening.
The duct system allows the efficient location
of discharge outlets in accordance with the
room layout
Duct connection is simpler with standard rear
intake chambers
BRC1E62
Navigation Remote Controller
(Wired Remote Controller)
Indoor unit
High
Low
21/26M
43
40
09/13/18M
41
38
(220V) dB(A)
Indoor unit
High
Low
30M
44
36
26M
42
38
42/48M
46
37
36M
45
37
(220V) dB(A)
BRC4C64
A signal receiver must be added to the indoor unit.
Wireless remote controller
and signal receiver unit
are sold as a set.
Wireless LCD remote controller
Wired LCD remote controller
BRC1C61
Accessory required for indoor unit
Option
Signal receiver unit
(Separate type)
BRC1E62
Navigation Remote Controller
(Wired Remote Controller)
FDBNQ09/13/18/21/26MV1
FDMNQ26/30/36/42/48MV1
DUCT CONNECTION LOW STATIC PRESSURE TYPE
45
/
37
dB(A)
FDMNQ36M
(220V)
High
Low
Sound level
43
/
40
dB(A)
FDBNQ26M
(220V)
High
Low
Sound level
Ideal for quiet, beautiful living spaces
Unit can be mounted in the ceiling and air can be
delivered freely by duct.
Suitable for condominiums and apartments,
houses and hotels
•
•
*1
•
•
•
*4
Comfort
Work & Servicing
Control features
Others
Features
*
1
Applicable when wired remote controller is used
*
2
Applicable when BRC1E62 is used
*
3
Applicable when BRC1C61 is used
*
4
For the outdoor units
Switchable fan speed
(2 step)
Programme "Dry"
*4
Pre charged for
up to 10 m
Control by 2 remote
controllers
Auto-restart
Group control by 1 remote
controller
Anti corrosion treated
heat exchangers
Two selectable
temperature-sensors
Remote controller
*2
*2
*2
*2
*3
Setpoint range set
Weekly schedule timer
Setpoint auto reset
Off timer (programmed)
On/Off timer
•
•
*1
•
•
•
*6
Comfort
Work & Servicing
Control features
Others
Features
*
1
Applicable when wired remote controller is used
*
2
Applicable when BRC1E62 is used
*
3
Applicable when BRC1C61 is used
*
4
Applicable to RNQ30-48M outdoor units
*
5
Applicable to RNQ26M outdoor units
*
6
For the outdoor units
Switchable fan speed
(2 step)
Programme "Dry"
*4
Pre charged for
up to 15 m
*5
Pre charged for
up to 10 m
Control by 2 remote
controllers
Auto-restart
Group control by 1 remote
controller
Anti corrosion treated
heat exchangers
Two selectable
temperature-sensors
Remote controller
*2
*2
*2
*2
*3
Setpoint range set
Weekly schedule timer
Setpoint auto reset
Off timer (programmed)
On/Off timer
Simultaneous air conditioning of two rooms and ventilation grille
(ventilation opening)
Ventilation grille
Door-installed
ventilation grille
Ventilation grille
Wall-installed
ventilation grille
Under-door cutout
Under-door cutout
When air conditioning two rooms
simultaneously, the air discharged into each
room must be circulated back to the air
conditioner. To achieve this, a ventilation duct
should be installed for each room or one of the
indicated ventilation grilles should be installed
on the partitioning wall or under the door
between the rooms.
Ventilates air through
the partitioning wall.
(See right)
Partitioning wall
Note: The under-door cutout method should be used only when there is a small volume of airflow.
(This feature also applies to duct connection middle static pressure type.)
Compact
Small, lightweight, and easy-to-install indoor unit.
Suction chamber
Air filter
(Note)
[Duct connection]
or more
or more
or more
To prevent increased
operation sound,
avoid installing the
air suction grille
directly below the
suction chamber.
Note : 270 mm is the minimum size.
Extra height is necessary for drain piping slope and insulation.
Note : 325 mm is the minimum size.
Extra height is necessary for drain piping slope and insulation.
Air conditioner
305 mm
Ordinary duct
(procured locally)
Air discharge
Air intake
(Note)
or more
or more
or more
325
325
mm
mm
325
mm
Ordinary duct
(procured locally)