DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

Freedom of layout

BRC4C64

A signal receiver must be added to the indoor unit. 

Wireless remote controller 
and signal receiver unit 
are sold as a set.

Wireless LCD remote controller

Wired LCD remote controller

BRC1C61

Accessory required for indoor unit

Option

Signal receiver unit

 (Separate type)

Switchable fan speed: High/Low

Drain pipe connection can be done inside 
the unit. Refrigerant and drain pipe outlets 
are at the same opening.

The duct system allows the efficient location 
of discharge outlets in accordance with the 
room layout

Duct connection is simpler with standard rear 
intake chambers

BRC1E62

Navigation Remote Controller

(Wired Remote Controller)

Indoor unit

High

Low

21/26M

43

40

09/13/18M

41

38

(220V) dB(A)

Indoor unit

High

Low

30M

44

36

26M

42

38

42/48M

46

37

36M

45

37

(220V) dB(A)

BRC4C64

A signal receiver must be added to the indoor unit. 

Wireless remote controller 
and signal receiver unit 
are sold as a set.

Wireless LCD remote controller

Wired LCD remote controller

BRC1C61

Accessory required for indoor unit

Option

Signal receiver unit

 (Separate type)

BRC1E62

Navigation Remote Controller

(Wired Remote Controller)

FDBNQ09/13/18/21/26MV1

FDMNQ26/30/36/42/48MV1

DUCT CONNECTION LOW STATIC PRESSURE TYPE

45

/

37

dB(A)

FDMNQ36M

(220V)

High

Low

Sound level

43

/

40

dB(A)

FDBNQ26M

(220V)

High

Low

Sound level

Ideal for quiet, beautiful living spaces

Unit can be mounted in the ceiling and air can be 
delivered freely by duct.

Suitable for condominiums and apartments, 
houses and hotels

*1

*4

Comfort

Work & Servicing

Control features

Others

Features

 

*

1

Applicable when wired remote controller is used

*

2

Applicable when BRC1E62 is used

*

3

Applicable when BRC1C61 is used

*

4

For the outdoor units

 

Switchable fan speed 

(2 step)

Programme "Dry"

*4

Pre charged for 

up to 10 m

Control by 2 remote 

controllers

Auto-restart

Group control by 1 remote 

controller

Anti corrosion treated

heat exchangers

Two selectable 

temperature-sensors

Remote controller

*2

*2

*2

*2

*3

Setpoint range set

Weekly schedule timer

Setpoint auto reset

Off timer (programmed)

On/Off timer

*1

*6

Comfort

Work & Servicing

Control features

Others

Features

 

*

1

Applicable when wired remote controller is used

*

2

Applicable when BRC1E62 is used

*

3

Applicable when BRC1C61 is used

*

4

Applicable to RNQ30-48M outdoor units

*

5

Applicable to RNQ26M outdoor units

*

6

For the outdoor units

 

Switchable fan speed 

(2 step)

Programme "Dry"

*4

Pre charged for 

up to 15 m

*5

Pre charged for 

up to 10 m

Control by 2 remote 

controllers

Auto-restart

Group control by 1 remote 

controller

Anti corrosion treated

heat exchangers

Two selectable 

temperature-sensors

Remote controller

*2

*2

*2

*2

*3

Setpoint range set

Weekly schedule timer

Setpoint auto reset

Off timer (programmed)

On/Off timer

Simultaneous air conditioning of two rooms and ventilation grille

 (ventilation opening)

Ventilation grille

Door-installed

ventilation grille

Ventilation grille

Wall-installed

ventilation grille

Under-door cutout

Under-door cutout

When air conditioning two rooms 
simultaneously, the air discharged into each 
room must be circulated back to the air 
conditioner.  To achieve this, a ventilation duct 
should be installed for each room or one of the 
indicated ventilation grilles should be installed 
on the partitioning wall or under the door  
between the rooms.

Ventilates air through 
the partitioning wall. 
(See right)

Partitioning wall

Note: The under-door cutout method should be used only when there is a small volume of airflow.

(This feature also applies to duct connection middle static pressure type.)

Compact

Small, lightweight, and easy-to-install indoor unit.

Suction chamber

Air filter

(Note)

[Duct connection]

or more

or more

or more

To prevent increased 
operation sound, 
avoid installing the 
air suction grille 
directly below the 
suction chamber.

Note : 270 mm is the minimum size. 
           Extra height is necessary for drain piping slope and insulation.

Note : 325 mm is the minimum size. 
           Extra height is necessary for drain piping slope and insulation.

Air conditioner
305 mm

Ordinary duct 

(procured locally)

Air discharge

Air intake

(Note)

or more

or more

or more

325

325

 mm

 mm

325

 mm

Ordinary duct 

(procured locally)

Summary of Contents for PCSMT1420A

Page 1: ...ire or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and acces...

Page 2: ...YPE Round Flow Series Pair FCNQ18MV1 RNQ13MV1 FCNQ13MV1 FCNQ21MV1 FCNQ26MV1 RNQ26MY1 30 RNQ30MV1 FCNQ30MV1 RNQ30MY1 36 RNQ36MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1 FCNQ36MV1 RNQ36MY1 42 RNQ42MY1 FCNQ42MV1 48 2...

Page 3: ...still obtain the same feeling temperature and comfort Operation sound increases when using 2 way or 3 way flow 1 4 6 Cleanliness Comfort Work Servicing Control features Others Options Features Access...

Page 4: ...t higher owing to ambient conditions Note Air direction is set to the standard position when the unit is shipped from the factory The position can be changed from the remote controller Panel size is s...

Page 5: ...ide as was formerly the case The unit fits more snugly into tight spaces Flexible installation Uniform height and depth Compact design for small capacity models to meet tighter dimensional constraints...

Page 6: ...e sensors Remote controller 2 2 2 2 3 Setpoint range set Weekly schedule timer Setpoint auto reset Off timer programmed On Off timer 1 6 Comfort Work Servicing Control features Others Features 1 Appli...

Page 7: ...s DCS301BA61 Option Schedule timer Unified control of weekly schedule for up to 1 024 indoor units DST301BA61 Option Schedule timer sets on off time in 1 minute units to be executed twice a day for a...

Page 8: ...set as holiday 3 independent schedules can be set e g summer winter mid season Display is available in 11 languages Dot matrix display Backlight display Convenience Weekly schedule Multilingual displ...

Page 9: ...te Others To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution coated Anti corrosion treated heat exchangers with special acryl pretreatment are used for...

Page 10: ...42 000 4 51 2 73 48 FHNQ48MV1 RNQ42MY1 RNQ48MY1 14 1 48 000 5 51 2 56 42 44 24 26 1 483 1 553 847 918 3 Phase 380 415 V 50 Hz Outdoor unit Outdoor unit Cooling capacity1 2 kW Y1 V1 Y1 V1 kW Power cons...

Page 11: ...air intake kit Chamber type 1 2 High efficiency filter2 High humidity operation kit Ultra long life filter2 19 20 Indoor unit Indoor unit OPTIONS Outdoor unit Kit name RNQ18MV1 RNQ21MV1 RNQ09MV1 RNQ13...

Page 12: ...e ceiling opening keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured 5 Please do not place the thing been damp and tr...

Page 13: ...pension bracket 5 6 7 8 300 or more 7 P150 1050 263 151 20 M4 Holes 51 1350 1137 16 1121 8 10 305 All Around 16 150 74 280 1153 7 5 6 4 1114 1134 1 29 50 123 18 M4 Holes 152 206 274 175 2 305 All Arou...

Page 14: ...IMENSIONS Unit mm Gas pipe connection Liquid pipe connection Service port Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection 1 2 3 4 5...

Page 15: ...sed body embedded cord Conduit CONTROL BOX Through hole Size Specifications of cord 0 75 1 25 mm2 Total length 500 m Type Vinyl cord with sheath or cable Insulated thickness 1 mm or more Note 1 Remote...

Page 16: ...29 30 MEMO...