CEILING MOUNTED CASSETTE TYPE
CEILING SUSPENDED TYPE
DUCT CONNECTION LOW STATIC PRESSURE TYPE
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
SPECIFICATIONS
43/39
24
White
VP20 (I.D o/20
X
O.D o/26)
19.4 to 46
o/6.4
49
36
40
49
---------
---------
---------
1.2
(Charged for 10 m)
0.9
51
1.4
(Charged for 10 m)
1.4
52
1.5
(Charged for 10 m)
1.8
2.0
(Charged for 10 m)
2.2
1.9
(Charged for 15 m)
3.2
(Charged for 15 m)
2.7
2.7
(Charged for 15 m)
3.75
3.2
(Charged for 15 m)
4.5
Ivory white
30
10
15
Hermetically sealed rotary type
o/12.7
o/15.9
o/18.0 (Hole)
°CWB
°CDB
Certified operation range
Certified operation range
Motor output
Compressor
Dimensions (H
X
W
X
D)
Colour
mm
dB(A)
kW
Refrigerant charge (R-410A)
kg
dB(A)
Sound level
3
Dimensions (H
X
W
X
D)
mm
Machine weight
kg
kg
V1
Y1
Piping
connections
mm
Liquid (Flare)
mm
Gas (Flare)
mm
Drain
Indoor unit
Outdoor unit
Machine weight
kg
Airflow rate (H/L)
m
3
/min
16/-
565/-
Outdoor
unit
Colour
mm
Heat insulation
Max. interunit piping length
m
m
Max. installation level difference
Type
Sound level (H/L) (220 V)
3
Indoor
unit
Both liquid and gas piping
cfm
14 to 23
14 to 25
17
18
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
°CDB
Certified Operation range
Sound level
3
°CWB
Certified Operation range
Motor output
Compressor
Dimensions
(H
X
W
X
D)
Colour
mm
mm
dB(A)
kW
Refrigerant charge (R-410A)
kg
dB(A)
Dimensions (H
X
W
X
D)
mm
Machine weight
kg
V1
Y1
Unit
Piping
connections
mm
Liquid (Flare)
mm
Gas (Flare)
mm
Drain
Indoor unit
Outdoor unit
Decoration panel
Unit
Decoration panel
Machine
weight
kg
kg
Unit
Decoration panel
Airflow rate (H/L)
m
3
/min
cfm
Outdoor
unit
Colour
mm
Heat insulation
Max. interunit piping length
m
m
Max. installation level difference
Type
Sound level (H/L)
3
Indoor
unit
Hermetically sealed rotary type
Hermetically sealed scroll type
o/6.4
o/15.9
o/12.7
50
X
950
X
950
5.5
----------
10
15
20
30
Ivory white
Fresh white
Both liquid and gas piping
30
30
(Equivalent length 50)
30
(Equivalent length 50)
50
(Equivalent length 70)
o/26.0 (Hole)
o/18.0 (Hole)
VP25 (I.D o/25
X
O.D o/32)
19.4 to 46
o/9.5
21 to 46
14 to 23
14 to 25
0.9
1.4
1.8
2.2
2.7
3.75
4.5
31/28
35/28
43/32
44/34
44/36
49
51
52
54
55
54
56
58
36
40
49
56
77
103
---------
---------
---------
---------
---------
56
74
103
107
111
19.5
21
24
256
X
840
X
840
298
X
840
X
840
1.2
(Charged for 10 m)
1.4
(Charged for 10 m)
1.5
(Charged for 10 m)
2.0
(Charged for 10 m)
1.9
(Charged for 15 m)
3.2
(Charged for 15 m)
2.7
(Charged for 15 m)
3.2
(Charged for 15 m)
13/10
21/13.5
32/20
33/22.5
459/353
741/477
1,130/706
1,165/794
Cooling capacity
1,2
kW
Y1
V1
Y1
V1
kW
Power consumption
Model
Name
Indoor unit
Power supply
Cooling
1
Btu/h
W/W
COP
13
FCNQ13MV1
RNQ13MV1
3.8
13,000
550
X
765
X
285
1.24
3.07
18
FCNQ18MV1
RNQ18MV1
5.3
18,000
595
X
845
X
300
1.89
2.80
2.80
21
FCNQ21MV1
RNQ21MV1
---------
---------
---------
6.2
21,000
2.21
26
FCNQ26MV1
RNQ26MV1
7.6
26,000
735
X
825
X
300
735
X
825
X
300
2.53
3.00
30
FCNQ30MV1
RNQ30MV1
8.8
30,000
990
X
940
X
320
2.73
3.22
36
FCNQ36MV1
RNQ36MV1
RNQ26MY1
26
FHNQ26MV1
RNQ26MV1
RNQ26MY1
RNQ30MY1
RNQ36MY1
10.6
36,000
1,345
X
900
X
320
3.31
3.20
42
FCNQ42MV1
---------
12.5
42,600
4.15
3.01
48
FCNQ48MV1
---------
RNQ42MY1
RNQ48MY1
14.1
48,000
5.04
2.80
1 Phase, 220–240 V, 50 Hz
---------
---------
3 Phase, 380–415 V, 50 Hz
Hermetically sealed scroll type
o/9.5
o/26.0 (Hole)
50
(Equivalent length 70)
30
21 to 46
45/40
48/42
49/43
55
54
54
56
58
77
56
103
---------
---------
74
56
20
103
107
111
195
X
1,590
X
680
26-27/22-23
38-40/23-25
918-953/777-812
1,341-1,412/812-883
30
FHNQ30MV1
RNQ30MV1
8.8
30,000
990
X
940
X
320
3.07
2.87
7.6
26,000
2.65
36
FHNQ36MV1
RNQ36MV1
RNQ30MY1
RNQ36MY1
10.4
35,000
1,345
X
900
X
320
3.64
2.86
42
FHNQ42MV1
---------
12.3
42,000
4.51
2.73
48
FHNQ48MV1
---------
RNQ42MY1
RNQ48MY1
14.1
48,000
5.51
2.56
42-44/24-26
1,483-1,553/847-918
---------
3 Phase, 380–415 V, 50 Hz
Outdoor unit
Outdoor unit
Cooling capacity
1,2
kW
Y1
V1
Y1
V1
kW
Power consumption
Model
Name
Indoor unit
Power supply
Cooling
1
Btu/h
W/W
COP
13
FHNQ13MV1
RNQ13MV1
195
X
960
X
680
3.8
13,000
550
X
765
X
285
1.58
2.40
18
FHNQ18MV1
RNQ18MV1
195
X
1,160
X
680
195
X
1,400
X
680
26
32
35
44/40
777-812/671-706
22-23/19-20
5.3
18,000
595
X
845
X
300
2.04
2.60
2.60
21
FHNQ21MV1
RNQ21MV1
---------
---------
---------
6.2
21,000
2.38
1 Phase, 220–240 V, 50 Hz
---------
Outdoor unit
Outdoor unit
°CDB
°CWB
Certified Operation range
Certified Operation range
Motor output
Compressor
Indoor
unit
Dimensions (H
X
W
X
D)
Colour
mm
dB(A)
kW
Refrigerant charge
(R-410A)
Sound level
4
Sound level (H/L) (220 V)
4
dB(A)
Dimensions (H
X
W
X
D)
mm
Machine weight
kg
V1
Y1
Piping
connections
mm
Liquid (Flare)
mm
Gas (Flare)
mm
Drain
Indoor unit
Machine weight
kg
kg
Airflow rate (H/L)
3
Fan
Outdoor
unit
Colour
Heat insulation
Max. interunit piping length
m
m
Max. installation level difference
Type
----------
Both liquid and gas piping
mm
Outdoor unit
Ivory white
mmH
2
O
cfm
Rated external static pressure
3
10
15
20
19.4 to 46
21 to 46
14 to 23
14 to 25
m
3
/min
30
30
(Equivalent length 50 m)
3/4B (I.Do/21.6
X
O.Do/27.2)
o/6.4
o/9.5
o/12.7
o/9.5
o/15.9
o/18.0 (Hole)
0.65
0.9
1.4
1.8
2.2
25
32
35
36
40
49
56
----------
----------
----------
----------
56
Hermetically sealed rotary type
0.9
(Charged for 10 m)
1.2
(Charged for 10 m)
1.4
(Charged for 10 m)
1.5
(Charged for 10 m)
2.0
(Charged for 10 m)
459/388
13/11
635/530
18/15
41/38
43/40
48
49
51
52
54
2.0
Y1
V1
Y1
V1
Cooling capacity
1,2
kW
kW
Power consumption
Model
Name
Indoor unit
Power supply
Cooling
1
Btu/h
W/W
COP
09
FDBNQ09MV1
RNQ09MV1
260
X
900
X
580
2.7
9,200
550
X
765
X
285
0.86
3.14
13
FDBNQ13MV1
RNQ13MV1
3.8
13,000
1.28
2.97
18
FDBNQ18MV1
RNQ18MV1
5.2
17,700
595
X
845
X
300
2.06
2.52
21
FDBNQ21MV1
RNQ21MV1
260
X
1,300
X
580
6.2
21,000
2.38
2.60
26
FDBNQ26MV1
RNQ26MV1
---------
---------
---------
---------
RNQ26MY1
7.6
26,000
735
X
825
X
300
2.62
2.90
1 Phase, 220–240 V, 50 Hz
---------
3 Phase, 380–415 V, 50 Hz
Outdoor unit
Outdoor unit
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Please see fan characteristic document in detail.
4
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
°CDB
°CWB
Certified Operation range
Certified Operation range
Motor output
Compressor
Indoor
unit
Dimensions (H
X
W
X
D)
Colour
mm
dB(A)
kW
Refrigerant charge
(R-410A)
Sound level
4
Sound level (H/L) (220 V)
4
dB(A)
Dimensions (H
X
W
X
D)
mm
Machine weight
kg
V1
Y1
Piping
connections
mm
Liquid (Flare)
mm
Gas (Flare)
mm
Drain
Indoor unit
Machine weight
kg
kg
Airflow rate (H)
3
Fan
Outdoor
unit
Colour
Heat insulation
Max. interunit piping length
m
m
Max. installation level difference
Type
----------
Both liquid and gas piping
mm
Outdoor unit
Ivory white
mmH
2
O
cfm
Rated external static pressure
3
20
30
21 to 46
14 to 25
m
3
/min
30
(Equivalent length 50 m)
50
(Equivalent length 70 m)
3/4B (I.Do/21.6
X
O.Do/27.2)
o/9.5
o/15.9
o/26.0 (Hole)
o/18.0 (Hole)
2.2
2.7
3.75
4.5
43
52
56
77
103
----------
----------
56
74
103
107
111
Hermetically sealed rotary type
Hermetically sealed scroll type
2.0
(Charged for 10 m)
1.9
(Charged for 15 m)
3.2
(Charged for 15 m)
2.7
(Charged for 15 m)
3.2
(Charged for 15 m)
812
23
1,306
37
1,483
42
42/38
44/36
45/37
46/37
54
55
54
56
58
8.5
9.8
8.0
Y1
V1
Y1
V1
Cooling capacity
1,2
kW
kW
Power consumption
Model
Name
Indoor unit
Power supply
Cooling
1
Btu/h
W/W
COP
26
FDMNQ26MV1
RNQ26MV1
305
X
1,350
X
680
7.6
26,000
735
X
825
X
300
2.62
2.90
2.90
30
FDMNQ30MV1
RNQ30MV1
305
X
1,550
X
680
8.8
30,000
990
X
940
X
320
3.03
36
FDMNQ36MV1
RNQ36MV1
10.6
36,000
3.53
3.00
1,345
X
900
X
320
42
FDMNQ42MV1
---------
12.3
42,000
4.49
2.74
48
FDMNQ48MV1
---------
RNQ26MY1
RNQ30MY1
RNQ36MY1
RNQ42MY1
RNQ48MY1
14.1
48,000
5.56
2.54
1 Phase, 220–240 V, 50 Hz
---------
3 Phase, 380–415 V, 50 Hz
Outdoor unit
Outdoor unit
Summary of Contents for PCSMT1420A
Page 16: ...29 30 MEMO...