background image

* For dust concentration of 0.15 mg/m

3

(mm)

Uses quiet stream fan and other quiet 
technologies.

Turbulent flow

 is reduced

Straightening 

plate

Quiet 

stream fan

50°

18/21M

44

40

26/30M

45

40

36/42M

48

42

48M

49

43

Indoor unit

High

Low

13M

43

39

195

960

1,160

680

Height

Indoor unit

Width

Depth

13M

18/21M

1,400

1,590

26/30M

36/42/48M

Quiet operation

Easier to maintain

Sound operation has been reduced on the exposed 
ceiling suspended type unit.

Oil resistant grille

Note: Intended for use in salons, dining rooms, and ordinary sales 

floors, this specification is not suitable for kitchens or other 
harsh environments.

Oil-resistant plastic is used for the air suction grille. 
This satisfies durability in restaurants and other 
similar environments.

For all maintenance tasks, access is 
from bottom surface.

Two time settings (2500 hrs and 1250 hrs) are available to match 
the installation environment.  Maintenance time warning is 
displayed on the remote controller (filter sign).

It is easy to wipe dirt off the flat side and lower 
surfaces of the unit.

Easy-clean, flat surfaces

Long-life filter lasts about 1 year*

Diffuses comfortable air 
throughout the room

Installation flexibility for 
freedom of design

Dehumidification is microprocessor controlled to prevent abrupt and 
uncomfortable changes in air temperature.

Programme "Dry"

Auto-swing (up&down) brings comfort to the room.

Wide air discharge 
openings produce a 
spreading 100° airflow

Air is blown up to 50° in 
the downward direction.

Switchable fan speed: High/Low

Installable on 
ceilings 3.5 m high

100°

*Water used in the test-run can now be drained from 

the air discharge opening rather than from the side 
as was formerly the case.

The unit fits more snugly into tight spaces. 

Flexible installation

Uniform height and depth. Compact design for 
small-capacity models to meet tighter dimensional 
constraints.

30 

mm

      or more

30 

mm

      or more

Note :  Anechoic chamber conversion value, measured according to JIS 
parameters and criteria. During operation these values are somewhat higher 
owing to ambient conditions.

(220V) dB(A)

Pipes more easily rigged

Plastic cover is used to conceal piping work holes.
When piping work the cover is easily taken off, and after piping work 
easily attached again to conceal the holes.

All wiring and internal servicing can be done from 
under the unit

Non-flocking flap

Condensation does not easily 
form on and dirt does not 
cling to non-flocking flap. 
It is easy to clean.

Non-flocking flap

CEILING SUSPENDED TYPE

7

8

Upgrade to a quiet and 
compact system.

Upgrade to a quiet and 
compact system.

Accessory required for indoor unit.

Option

Wired LCD remote controller

Features

 

*

1

Installable on max. 3.5 m high ceiling

*

2

Applicable to RNQ30-48M outdoor units

*

3

Applicable to RNQ13-26M outdoor units

*

4

For the outdoor units

*1

*4

Cleanliness

Comfort

Work & Servicing

Control features

Others

Switchable fan speed 

(2 step)

Auto swing

Programme "Dry"

High ceiling application 

Anti-bacterial air filter

*3

Pre charged for 

up to 10 m

*2

Pre charged for 

up to 15 m

Long-life filter

Auto-restart

Anti corrosion treated

heat exchangers

Remote controller

On/Off timer

FHNQ13/18/21/26/30/36/42/48MV1

44

/

40

dB(A)

FHNQ21M

(220V)

High

Low

Sound level

BRC7NU66

A signal receiver must be added to the indoor unit. 

Note: Remote controller cable not 

included. Cables must be 
procured locally.

Wireless remote controller and signal 
receiver unit are sold as a set.

Wired  LCD remote controller

Wireless LCD remote controller

BRC1NU61

Signal receiver unit (Installed type)

Summary of Contents for PCSMT1420A

Page 1: ...ire or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and acces...

Page 2: ...YPE Round Flow Series Pair FCNQ18MV1 RNQ13MV1 FCNQ13MV1 FCNQ21MV1 FCNQ26MV1 RNQ26MY1 30 RNQ30MV1 FCNQ30MV1 RNQ30MY1 36 RNQ36MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1 FCNQ36MV1 RNQ36MY1 42 RNQ42MY1 FCNQ42MV1 48 2...

Page 3: ...still obtain the same feeling temperature and comfort Operation sound increases when using 2 way or 3 way flow 1 4 6 Cleanliness Comfort Work Servicing Control features Others Options Features Access...

Page 4: ...t higher owing to ambient conditions Note Air direction is set to the standard position when the unit is shipped from the factory The position can be changed from the remote controller Panel size is s...

Page 5: ...ide as was formerly the case The unit fits more snugly into tight spaces Flexible installation Uniform height and depth Compact design for small capacity models to meet tighter dimensional constraints...

Page 6: ...e sensors Remote controller 2 2 2 2 3 Setpoint range set Weekly schedule timer Setpoint auto reset Off timer programmed On Off timer 1 6 Comfort Work Servicing Control features Others Features 1 Appli...

Page 7: ...s DCS301BA61 Option Schedule timer Unified control of weekly schedule for up to 1 024 indoor units DST301BA61 Option Schedule timer sets on off time in 1 minute units to be executed twice a day for a...

Page 8: ...set as holiday 3 independent schedules can be set e g summer winter mid season Display is available in 11 languages Dot matrix display Backlight display Convenience Weekly schedule Multilingual displ...

Page 9: ...te Others To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution coated Anti corrosion treated heat exchangers with special acryl pretreatment are used for...

Page 10: ...42 000 4 51 2 73 48 FHNQ48MV1 RNQ42MY1 RNQ48MY1 14 1 48 000 5 51 2 56 42 44 24 26 1 483 1 553 847 918 3 Phase 380 415 V 50 Hz Outdoor unit Outdoor unit Cooling capacity1 2 kW Y1 V1 Y1 V1 kW Power cons...

Page 11: ...air intake kit Chamber type 1 2 High efficiency filter2 High humidity operation kit Ultra long life filter2 19 20 Indoor unit Indoor unit OPTIONS Outdoor unit Kit name RNQ18MV1 RNQ21MV1 RNQ09MV1 RNQ13...

Page 12: ...e ceiling opening keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured 5 Please do not place the thing been damp and tr...

Page 13: ...pension bracket 5 6 7 8 300 or more 7 P150 1050 263 151 20 M4 Holes 51 1350 1137 16 1121 8 10 305 All Around 16 150 74 280 1153 7 5 6 4 1114 1134 1 29 50 123 18 M4 Holes 152 206 274 175 2 305 All Arou...

Page 14: ...IMENSIONS Unit mm Gas pipe connection Liquid pipe connection Service port Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection 1 2 3 4 5...

Page 15: ...sed body embedded cord Conduit CONTROL BOX Through hole Size Specifications of cord 0 75 1 25 mm2 Total length 500 m Type Vinyl cord with sheath or cable Insulated thickness 1 mm or more Note 1 Remote...

Page 16: ...29 30 MEMO...