Airflow 

distribution

Creates uniform 

comfort throughout 

the space

Comfort enhanced by Round Flow!

With uniform temperature 

distribution

Enhanced Comfort

Greater comfort

Improved energy saving

• Condition after exposure 

to the smoke of 600 
cigarettes in 1 m

3

 

enclosed space.

Treated 

surface

Untreated 

surface

Grimy 

surface

Resists 

soiling

External panels are treated with a coating that 
repels dirt.

Avoids uneven temperature and discomfort caused by drafts.

To prevent dirt sticking to the 
external panels, they have 
been coated with a surface 
treatment.

Because air flows out from corner outlets, comfort spreads more widely.

360° airflow

Air movement is gentle with Round Flow

Condensation does not easily form on and dirt does not 
cling to non-flocking flaps. 
It is easy to clean.

Non-flocking flaps

Prevents mould and microorganisms growing out of the dust and 
moisture that adheres to the filters.

Filter has anti-mould and bactericidal treatment

Grime prevention and bactericidal coating: Make cleaning easier.

Adapts easily to the installation space.

Note: Whatever the discharge direction, the same type of panel is used. If  installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to 

close each unused outlet.

3-way flow

L-shaped 

2-way flow

Opposite 

2-way flow

(E.g., installed in 

a corner)

(E.g., installed in 

a long room)

(E.g., installed 

near a wall)

(E.g., installed in 

middle of ceiling)

4-way flow also possible.

All-round flow

360° airflow can 
maintain comfort 
even if air 
discharge speed is 
lower.

Typical flow patterns

There are a total of 23 flow patterns. 

If you raise the set 
temperature by 1 to 
1.5°C,and velocity is 
decreased by 25%, 
you still obtain the same 
feeling temperature and 
comfort.

Operation sound  increases when using 2-way or 3-way flow.

• • • • •

*1

*4

• • • • • •

• •

*6

Cleanliness

Comfort

Work & Servicing

Control features

Others

Options

Features

 

Accessory required for indoor unit.

Option

*

1

Applicable when wired remote controller is used

*

2

Applicable when BRC1E62 is used

*

3

Applicable when BRC1C61 is used

*

4

Applicable to RNQ30-48M outdoor units

*

5

Applicable to RNQ13-26M outdoor units

*

6

For the outdoor units

 

CEILING MOUNTED CASSETTE TYPE

FCNQ13/18/21/26/30/36/42/48MV1

Swing pattern selection

Switchable fan speed 

(2 step)

Auto swing

Programme "Dry"

High ceiling application 

Drain pump mechanism

Anti-bacterial air filter

Pre charged for 

up to 15 m

*5

Pre charged for 

up to 10 m

Long-life filter

Filter sign

Ceiling soiling prevention

Ultra long-life filter

High-efficiency filter

Fresh air intake kit

Control by 2 remote 

controllers

Auto-restart

Group control by 1 remote 

controller

External command 

control 

Central remote control

Interlock control

DIII-NET communication 

standard

Anti corrosion treated

heat exchangers

Two selectable 

temperature-sensors

Round Flow

BRC1E62

Navigation Remote Controller

(Wired Remote Controller)

BRC7F633F

A signal receiver must be added to the indoor unit. 

Wireless remote controller and signal 
receiver unit are sold as a set.

Wireless LCD remote controller

Signal receiver unit

 (Installed type)

Note: Remote controller cable not 

included. Cables must be 
procured locally.

Note: Remote controller cable not 

included. Cables must be 
procured locally.

Wired LCD remote controller

BRC1C61

3

4

Remote controller

*2

*2

*2

*2

*3

Setpoint range set

Weekly schedule timer

Setpoint auto reset

Off timer (programmed)

On/Off timer

Cassette air conditioner with 360° 
uniform airflow sets the standard

Cassette air conditioner with 360° 
uniform airflow sets the standard

43

/

32

dB(A)

FCNQ36M

(220V)

High

Low

Sound level

Summary of Contents for PCSMT1420A

Page 1: ...ire or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and acces...

Page 2: ...YPE Round Flow Series Pair FCNQ18MV1 RNQ13MV1 FCNQ13MV1 FCNQ21MV1 FCNQ26MV1 RNQ26MY1 30 RNQ30MV1 FCNQ30MV1 RNQ30MY1 36 RNQ36MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1 FCNQ36MV1 RNQ36MY1 42 RNQ42MY1 FCNQ42MV1 48 2...

Page 3: ...still obtain the same feeling temperature and comfort Operation sound increases when using 2 way or 3 way flow 1 4 6 Cleanliness Comfort Work Servicing Control features Others Options Features Access...

Page 4: ...t higher owing to ambient conditions Note Air direction is set to the standard position when the unit is shipped from the factory The position can be changed from the remote controller Panel size is s...

Page 5: ...ide as was formerly the case The unit fits more snugly into tight spaces Flexible installation Uniform height and depth Compact design for small capacity models to meet tighter dimensional constraints...

Page 6: ...e sensors Remote controller 2 2 2 2 3 Setpoint range set Weekly schedule timer Setpoint auto reset Off timer programmed On Off timer 1 6 Comfort Work Servicing Control features Others Features 1 Appli...

Page 7: ...s DCS301BA61 Option Schedule timer Unified control of weekly schedule for up to 1 024 indoor units DST301BA61 Option Schedule timer sets on off time in 1 minute units to be executed twice a day for a...

Page 8: ...set as holiday 3 independent schedules can be set e g summer winter mid season Display is available in 11 languages Dot matrix display Backlight display Convenience Weekly schedule Multilingual displ...

Page 9: ...te Others To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution coated Anti corrosion treated heat exchangers with special acryl pretreatment are used for...

Page 10: ...42 000 4 51 2 73 48 FHNQ48MV1 RNQ42MY1 RNQ48MY1 14 1 48 000 5 51 2 56 42 44 24 26 1 483 1 553 847 918 3 Phase 380 415 V 50 Hz Outdoor unit Outdoor unit Cooling capacity1 2 kW Y1 V1 Y1 V1 kW Power cons...

Page 11: ...air intake kit Chamber type 1 2 High efficiency filter2 High humidity operation kit Ultra long life filter2 19 20 Indoor unit Indoor unit OPTIONS Outdoor unit Kit name RNQ18MV1 RNQ21MV1 RNQ09MV1 RNQ13...

Page 12: ...e ceiling opening keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured 5 Please do not place the thing been damp and tr...

Page 13: ...pension bracket 5 6 7 8 300 or more 7 P150 1050 263 151 20 M4 Holes 51 1350 1137 16 1121 8 10 305 All Around 16 150 74 280 1153 7 5 6 4 1114 1134 1 29 50 123 18 M4 Holes 152 206 274 175 2 305 All Arou...

Page 14: ...IMENSIONS Unit mm Gas pipe connection Liquid pipe connection Service port Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection 1 2 3 4 5...

Page 15: ...sed body embedded cord Conduit CONTROL BOX Through hole Size Specifications of cord 0 75 1 25 mm2 Total length 500 m Type Vinyl cord with sheath or cable Insulated thickness 1 mm or more Note 1 Remote...

Page 16: ...29 30 MEMO...