background image

OUTDOOR UNIT // RNQ09/13MV1

23

24

DIMENSIONS

(Unit: mm)

22

50

100

50

150

50

50

300

150

100

285

8

Handle

Wall height on air outlet side 

=less than 1200

Minimum  space  for  air  passage

105.5

13

311

490

574

29.5

Drain outlet

(I.D.  15.9 

hose for connection)

4-Hole for anchor bolts

 (M8 or M10) 

550

12

63

765

Brand name label

Manufacture’s 

label

196

165

105

Wiring 

inlet

Gas stop valve

(   15.9CuT for RNQ13)

(   9.5CuT for RNQ09)

Service 

port

In case of removing 

stop valve cover

Liquid stop valve

(   6.4CuT)

300 or more

1353

1337

151

74

16

263

7×P150=1050

1550

(All Around)

51

20-M4 Holes

8

10

16

305

150

280

1321

50

123

1314

175

305

18-M4 Holes

212

206

(All Around)

152

827

274

1334

7×P150=1050

2

1

29

7

6

5

4

1353

146

3

151

600

116

(Suspension bolt pinch)

381

3

1403

1550

(Suspension bolt pinch)

126

55

427

8

680

Service space

[FDMNQ30/36/42/48MV1]

DUCT CONNECTION  MIDDLE STATIC PRESSURE TYPE

Note: 

1

Location of unit's Name Plate: Chamber cap

Liquid pipe connection 
Gas pipe connection
Drain pipe connection
Ground terminal 

1
2
3
4

Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket

5
6
7
8

300 or more

7×P150=1050

263

151

20-M4 Holes

51

1350

1137

16

1121

8

10

305

(All Around)

16

150

74

280

1153

7

5

6

4

1114

1134

1

29

50

123

18-M4 Holes

152

206

274

175

2

305

(All Around)

727

212

7×P150=1050

126

600

1350

8

116

1153

680

3

381

3

(Suspension bolt pinch)

146

1203

151

427

(Suspension bolt pinch)

55

Service space

Service space

300 or more

260

10

236

16

151

102

1300

219

1104

1074

1088

18-M4 Holes

16

(All Around)

52

10

150

6×P.150=900

700

50

16-M4 Holes

29

2

6×P150=900

164

134

1064

(All Around)

170

260

228

107

1084

1

110

5

6

4

7

10 or more

271

317

500

167

580

137

(Suspension bolt pinch)

(Suspension bolt pinch)

3

1300

151

55

1155

126

8

3

1104

[FDBNQ21/26MV1]

[FDMNQ26MV1]

DUCT CONNECTION  LOW STATIC PRESSURE TYPE

Note: 

1

Location of unit's Name Plate: Chamber cap

Liquid pipe connection 
Gas pipe connection
Drain pipe connection
Ground terminal 

1
2
3
4

Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket

5
6
7
8

DUCT CONNECTION  MIDDLE STATIC PRESSURE TYPE

Note: 

1

Location of unit's Name Plate: Chamber cap

Liquid pipe connection 
Gas pipe connection
Drain pipe connection
Ground terminal 

1
2
3
4

Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket

5
6
7
8

Summary of Contents for PCSMT1420A

Page 1: ...ire or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and acces...

Page 2: ...YPE Round Flow Series Pair FCNQ18MV1 RNQ13MV1 FCNQ13MV1 FCNQ21MV1 FCNQ26MV1 RNQ26MY1 30 RNQ30MV1 FCNQ30MV1 RNQ30MY1 36 RNQ36MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1 FCNQ36MV1 RNQ36MY1 42 RNQ42MY1 FCNQ42MV1 48 2...

Page 3: ...still obtain the same feeling temperature and comfort Operation sound increases when using 2 way or 3 way flow 1 4 6 Cleanliness Comfort Work Servicing Control features Others Options Features Access...

Page 4: ...t higher owing to ambient conditions Note Air direction is set to the standard position when the unit is shipped from the factory The position can be changed from the remote controller Panel size is s...

Page 5: ...ide as was formerly the case The unit fits more snugly into tight spaces Flexible installation Uniform height and depth Compact design for small capacity models to meet tighter dimensional constraints...

Page 6: ...e sensors Remote controller 2 2 2 2 3 Setpoint range set Weekly schedule timer Setpoint auto reset Off timer programmed On Off timer 1 6 Comfort Work Servicing Control features Others Features 1 Appli...

Page 7: ...s DCS301BA61 Option Schedule timer Unified control of weekly schedule for up to 1 024 indoor units DST301BA61 Option Schedule timer sets on off time in 1 minute units to be executed twice a day for a...

Page 8: ...set as holiday 3 independent schedules can be set e g summer winter mid season Display is available in 11 languages Dot matrix display Backlight display Convenience Weekly schedule Multilingual displ...

Page 9: ...te Others To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution coated Anti corrosion treated heat exchangers with special acryl pretreatment are used for...

Page 10: ...42 000 4 51 2 73 48 FHNQ48MV1 RNQ42MY1 RNQ48MY1 14 1 48 000 5 51 2 56 42 44 24 26 1 483 1 553 847 918 3 Phase 380 415 V 50 Hz Outdoor unit Outdoor unit Cooling capacity1 2 kW Y1 V1 Y1 V1 kW Power cons...

Page 11: ...air intake kit Chamber type 1 2 High efficiency filter2 High humidity operation kit Ultra long life filter2 19 20 Indoor unit Indoor unit OPTIONS Outdoor unit Kit name RNQ18MV1 RNQ21MV1 RNQ09MV1 RNQ13...

Page 12: ...e ceiling opening keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured 5 Please do not place the thing been damp and tr...

Page 13: ...pension bracket 5 6 7 8 300 or more 7 P150 1050 263 151 20 M4 Holes 51 1350 1137 16 1121 8 10 305 All Around 16 150 74 280 1153 7 5 6 4 1114 1134 1 29 50 123 18 M4 Holes 152 206 274 175 2 305 All Arou...

Page 14: ...IMENSIONS Unit mm Gas pipe connection Liquid pipe connection Service port Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection 1 2 3 4 5...

Page 15: ...sed body embedded cord Conduit CONTROL BOX Through hole Size Specifications of cord 0 75 1 25 mm2 Total length 500 m Type Vinyl cord with sheath or cable Insulated thickness 1 mm or more Note 1 Remote...

Page 16: ...29 30 MEMO...

Reviews: