 Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.

You can turn up to 16 indoor units on/off with a single remote 
controller. (When using connected indoor units, the settings 
must all be the same and on/off will be simultaneous.)

Group control by 1 remote controller

Two types are available: 65% and 90% colorimetry. 

High-efficiency filter unit

You can provide air-conditioning with fresh air from outside. 
Convenient for places where a ventilation fan cannot be 
installed. 

Fresh-air intake kit

Work and Servicing

Control features

Options

Steeper gradient realises more 
efficient condensate drainage. 
High-lift is especially useful for 
long lengths of drain piping.

Maintenance is not required for one year.
The filter is washable and can be reused.

If refrigerant piping length does not exceed 15 m, there is no 
need for on-site gas charging. 

The filter sign warns you when it is time to clean the filter. 

*When using a wired remote controller the sign is displayed in the LCD. 
When using a wireless remote controller the filter sign lamp illuminates on 
the signal receiver unit.

Drain pump mechanism

Long-life filter

Pre charged for up to 15 metres

Filter sign

Daikin's innovative air discharge mechanism keeps airflow 
away from the ceiling. Ceiling cleaning is less frequently 
required.

Ceiling soiling prevention function

If there is a power outage while the equipment is operating, 
operations will restart in the same mode as before the power 
cut when electricity is restored.

Ultra long-life filter

Auto-restart

Optional central remote controller enables centralised control of 
up to 1024 indoor units (64 groups) from up to 1 kilometer away.

Central remote control

Enables interlocking control with external equipment such as 
Heat Reclaim Ventilator.

Interlock control

Standardly equipped interface enables connection to 
centralised control system without need of an adaptor.

DIII-NET communication standard

Using 2 remote controllers you can operate the equipment 
locally or from a remote location.

Note: When a wireless remote controller is used, remote control by two 
remote controllers is not possible.

Control by 2 remote controllers

RNQ09-26M : 10 m

*Applicable to RNQ30-48M.

Requires no maintenance for about 4 years* (10,000h) in 
stores and offices.

*For dust concentration of 0.15 mg/m

3

*Connecting ducts, insect nets, fire dampers, air filters, and other parts 

should, as required, be procured locally. 

**Outside Air fan interlocked with air conditioning unit is necessary. 

Optional PCB(KRP1C63)is required for interlocking.

***It is recommended that the volume of outdoor air introduced through the 

kit is limited to 10% of the maximum airflow rate of the indoor unit. 
Introducing higher quantities will increase the operating noise and may 
also influence temperature sending. 

Note: 

Others

To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated 
heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
In high corrosive areas, regular maintenance needs to be carried out.

Anti corrosion treated heat exchangers

Operation and surveillance is carried out using the contact 
signal from the operation control box in the building 
surveillance (security) room.

External command control

*An option is required.

15

16

Abundance of functions that provide comfortable 
air-conditioning in stores and offices.

Cleanliness

The Air filter has a anti-bacterial treatment to help prevent the growth of bacteria and mould on it.

Anti-bacterial air filter

 Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.

Note: Wireless remote controllers have no 

temperature-sensor.

Use the temperature-sensor in 
the indoor unit when controlling 
air conditioning from another 
room.

Dehumidification is microprocessor controlled to prevent 
abrupt and uncomfortable changes in air temperature. Useful 
for reducing uncomfortable humidity without uncomfortable 
cooling of the room.

Delivers comfortable 
air-conditioning to all areas, near 
to and far from the 
air-conditioner.

High setting provides maximum reach while low setting 
minimises drafts.

Auto-swing

Programme "Dry"

Switchable fan speed

(1) Standard setting

(2) Ceiling soiling prevention 

setting

(standard, ceiling soiling prevention)

Note:When units are installed on high ceilings, depending on the model, 

various restrictions concerning maximum height, air discharge direction, 
and choice of options may apply.

You can freely set 2 air discharge setting by remote controller.

Swing pattern selection

Delivers air-conditioning comfort all the way down to the floor 
in air-conditioning zones with high ceilings.

High-ceiling application

Two selectable temperature-sensors

Comfort

The air flow direction can be 
fixed at your desited angle 
by the remote controller.

Temperature-sensors are included in the indoor unit and 
optional wired remote controller.  Temperature sensing closer 
to target area is possible to further increase the comfort level.

Remote Controller

Sets and saves setting for an increment of time that 
automatically turns off air conditioner after a preset period of 
time for each time operation starts.

Off timer (programmed)

Operation starts when the preset time of the ON timer elapses 
and stops when the preset time of the OFF timer elapses.

On/Off timer

Up to five operation ON/OFF settings can be programmed per 
day for each day of the week. Not only can the time be set for 
the operation ON setting, but also the temperature.

Weekly schedule timer

Even if the set temperature is changed, it returns to the preset 
temperature after a preset period of time.

Saves energy by limiting the minimum and maximum set 
temperatures.  Avoids excessive heating and cooling.

Setpoint auto reset

Setpoint range set

Summary of Contents for PCSMT1420A

Page 1: ...ire or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and acces...

Page 2: ...YPE Round Flow Series Pair FCNQ18MV1 RNQ13MV1 FCNQ13MV1 FCNQ21MV1 FCNQ26MV1 RNQ26MY1 30 RNQ30MV1 FCNQ30MV1 RNQ30MY1 36 RNQ36MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1 FCNQ36MV1 RNQ36MY1 42 RNQ42MY1 FCNQ42MV1 48 2...

Page 3: ...still obtain the same feeling temperature and comfort Operation sound increases when using 2 way or 3 way flow 1 4 6 Cleanliness Comfort Work Servicing Control features Others Options Features Access...

Page 4: ...t higher owing to ambient conditions Note Air direction is set to the standard position when the unit is shipped from the factory The position can be changed from the remote controller Panel size is s...

Page 5: ...ide as was formerly the case The unit fits more snugly into tight spaces Flexible installation Uniform height and depth Compact design for small capacity models to meet tighter dimensional constraints...

Page 6: ...e sensors Remote controller 2 2 2 2 3 Setpoint range set Weekly schedule timer Setpoint auto reset Off timer programmed On Off timer 1 6 Comfort Work Servicing Control features Others Features 1 Appli...

Page 7: ...s DCS301BA61 Option Schedule timer Unified control of weekly schedule for up to 1 024 indoor units DST301BA61 Option Schedule timer sets on off time in 1 minute units to be executed twice a day for a...

Page 8: ...set as holiday 3 independent schedules can be set e g summer winter mid season Display is available in 11 languages Dot matrix display Backlight display Convenience Weekly schedule Multilingual displ...

Page 9: ...te Others To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution coated Anti corrosion treated heat exchangers with special acryl pretreatment are used for...

Page 10: ...42 000 4 51 2 73 48 FHNQ48MV1 RNQ42MY1 RNQ48MY1 14 1 48 000 5 51 2 56 42 44 24 26 1 483 1 553 847 918 3 Phase 380 415 V 50 Hz Outdoor unit Outdoor unit Cooling capacity1 2 kW Y1 V1 Y1 V1 kW Power cons...

Page 11: ...air intake kit Chamber type 1 2 High efficiency filter2 High humidity operation kit Ultra long life filter2 19 20 Indoor unit Indoor unit OPTIONS Outdoor unit Kit name RNQ18MV1 RNQ21MV1 RNQ09MV1 RNQ13...

Page 12: ...e ceiling opening keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured 5 Please do not place the thing been damp and tr...

Page 13: ...pension bracket 5 6 7 8 300 or more 7 P150 1050 263 151 20 M4 Holes 51 1350 1137 16 1121 8 10 305 All Around 16 150 74 280 1153 7 5 6 4 1114 1134 1 29 50 123 18 M4 Holes 152 206 274 175 2 305 All Arou...

Page 14: ...IMENSIONS Unit mm Gas pipe connection Liquid pipe connection Service port Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection 1 2 3 4 5...

Page 15: ...sed body embedded cord Conduit CONTROL BOX Through hole Size Specifications of cord 0 75 1 25 mm2 Total length 500 m Type Vinyl cord with sheath or cable Insulated thickness 1 mm or more Note 1 Remote...

Page 16: ...29 30 MEMO...