background image

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

English

Deutsc

h

Français

Nederlands

Español

Italiano

ÅëëçíéêÜ

P

o

rtugues

Ðóññêèé

Türkçe

MODELS

FTXS60GV1B
FTXS71GV1B

00_CV_3P248442-3.fm  Page 1  Tuesday, September 8, 2009  1:14 PM

Summary of Contents for Super Multi NX FTXS60GV1B

Page 1: ...IKIN ROOM AIR CONDITIONER OPERATION MANUAL English Deutsch Fran ais Nederlands Espa ol Italiano Portugues T rk e MODELS FTXS60GV1B FTXS71GV1B 00_CV_3P248442 3 fm Page 1 Tuesday September 8 2009 1 14 P...

Page 2: ...the Airflow Direction 12 COMFORT AIRFLOW and INTELLIGENT EYE Operation 14 POWERFUL Operation 17 OUTDOOR UNIT QUIET Operation 18 ECONO Operation 19 OFF TIMER Operation 20 ON TIMER Operation 21 WEEKLY...

Page 3: ...air conditioner until a qualified service person confirms that the leakage has been repaired Do not attempt to install or repair the air conditioner yourself Improper workmanship may result in water l...

Page 4: ...lfunctions smoke or fire when making contact with electrical parts Do not place objects around the indoor unit Doing so may have an adverse influence on the performance product quality and life of the...

Page 5: ...4 Names of Parts Indoor Unit 17 16 13 15 14 1 3 4 5 9 11 10 8 2 6 12 7 01_EN_3P248442 3 fm Page 4 Tuesday September 8 2009 1 54 PM...

Page 6: ...ble This switch is useful when the remote controller is missing 14 OPERATION lamp green 15 TIMER lamp yellow page 20 16 INTELLIGENT EYE lamp green page 14 17 Signal receiver It receives signals from t...

Page 7: ...AT FAN page 10 8 QUIET button OUTDOOR UNIT QUIET operation page 18 9 ECONO button ECONO operation page 19 10 SWING button Flaps horizontal blades page 12 11 SWING button Louvers vertical blades page 1...

Page 8: ...en the system is not used for a long time take the batteries out The batteries will last for approx 1 year If the remote controller display begins to fade and the degradation of reception performance...

Page 9: ...5 Press Always point the remote controller at the indoor unit when pushing the buttons when setting the indoor unit s internal clock blinks Turn the breaker on Turning on the breaker opens once and c...

Page 10: ...40 to 55W of power at the time of compressor preheating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off Use the air conditioner...

Page 11: ...sequence 2 Press is displayed on the LCD The OPERATION lamp lights up To stop operation 3 Press again disappears from the LCD Then OPERATION lamp goes off To change the temperature setting 4 Press or...

Page 12: ...g operation to take away the frost During defrosting operation hot air does not flow out of indoor unit A pinging sound may be heard during defrosting operation which however does not mean that the ai...

Page 13: ...vertical blades will begin to swing Press and and are displayed on the LCD The flaps and louvers move in turn To cancel 3 D airflow press either or again The flaps or louvers will stop moving The fol...

Page 14: ...ouvers angles In side the air outlet a fan is rotating at a high speed Note on the angles of the flaps The flaps swinging range depends on the operation See the figure Note on 3 D airflow Using 3 D ai...

Page 15: ...LIGENT EYE operation The air conditioner can go into operation with the COMFORT AIRFLOW and INTELLIGENT EYE operation combined COOL operation HEAT operation When somebody in the room When nobody in th...

Page 16: ...amp lights up The lamp will be lit while human movements are detected To cancel operation Press and select blank on the LCD INTELLIGENT EYE operation is useful for energy saving Energy saving operatio...

Page 17: ...e etc The sensor also mistakenly detects pets sunlight fluttering curtains and light reflected off of mirrors as passersby INTELLIGENT EYE operation will not go on during POWERFUL operation NIGHT SET...

Page 18: ...sed last POWERFUL operation can only be set when the unit is running POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its ma...

Page 19: ...nits However if using priority room setting see note for multi system page 30 This function is available in COOL HEAT and AUTO operation This is not available in FAN and DRY operation POWERFUL operati...

Page 20: ...connecting outdoor unit NOTE Notes on ECONO operation ECONO operation can only be set when the unit is running ECONO operation is a function which enables efficient operation by limiting the power con...

Page 21: ...MER lamp lights up To cancel the OFF TIMER Operation 4 Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off NOTE Notes on TIMER operation...

Page 22: ...ting rapidly 3 Press again The TIMER lamp lights up To cancel ON TIMER operation 4 Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off To...

Page 23: ...servations The use of ON ON ON ON settings for example makes it possible to schedule operating mode and set temperature changes Furthermore by using OFF OFF OFF OFF settings only the turn off time of...

Page 24: ...vation number and the day of the week 3 Press The day of the week and reservation number will be set and blink 4 Press to select the desired mode Pressing the changes or setting in sequence In case th...

Page 25: ...1 to 32 C To return to the time setting press The set temperature is only displayed when the mode setting is on 9 Press The temperature will be set and go to the next reservation setting To continue f...

Page 26: ...standby state and will disappear from the LCD When ON OFF TIMER is up the WEEKLY TIMER will automatically become active Only the time and set temperature set with the weekly timer are sent with the Se...

Page 27: ...Press to activate copy mode The whole reservation of the selected day of the week will be copied 4 Press to select the destination day of the week Copy mode 6 00 8 30 17 30 22 00 25 C 27 C 6 00 8 30 1...

Page 28: ...displayed on the LCD and WEEKLY TIMER operation is activated NOTE Note on COPY MODE The entire reservation of the source day of the week is copied in the copy mode In the case of making a reservation...

Page 29: ...ress The mode is switched to setting mode Go to setting mode step 4 page 23 3 Press to exit confirming mode is displayed on the LCD and WEEKLY TIMER operation is activated The TIMER lamp lights up To...

Page 30: ...o be canceled with 7 Hold for 5 seconds The reservation of the selected day of the week will be deleted 8 Hold for 5 seconds while normal display Be sure to direct the remote control toward the main u...

Page 31: ...ctivated when the temperature drops 5 C or more below the highest temperature recorded that day Therefore when the temperature difference is less than 5 C this function will not be activated NIGHT QUI...

Page 32: ...rity As the operation mode of the priority room takes precedence the user can select a different operation mode from other rooms Room A is the priority room in the examples Example When COOL operation...

Page 33: ...e left and right of the front panel with the slots then push them all the way in Close the front panel slowly Press the panel at both sides and the center CAUTION CAUTION Before cleaning be sure to st...

Page 34: ...3 1 1 Wash the air filters with water or clean them with vacuum cleaner If the dust does not come off easily wash them with neutral detergent thinned with lukewarm water then dry them up in the shade...

Page 35: ...se the filter frame when replacing the titanium apatite photocatalytic air purifying filter Dispose of the old filter as non flammable waste 4 Set the air filter and titanium apatite photocatalytic ai...

Page 36: ...use gases covered by the Kyoto Protocol Refrigerant type R410A GWP 1 value 1975 1 GWP global warming potential Periodical inspections for refrigerant leaks may be required depending on European or loc...

Page 37: ...lected This is to protect the air conditioner You should wait for about 3 minutes A sound is heard A sound like a flow of water This sound is generated because the refrigerant in the air conditioner i...

Page 38: ...in temperature Operation stopped suddenly OPERATION lamp flashes Are the air filters clean Is there anything to block the air inlet or the outlet of the indoor and the outdoor units Clean the air filt...

Page 39: ...nits Is the temperature setting appropriate Are the windows and doors closed Are the airflow rate and the airflow direction set appropriately Remote controller does not work properly No remote control...

Page 40: ...service shop where you bought the air conditioner The outdoor fan rotates while the air conditioner is not in operation After operation is stopped The outdoor fan continues rotating for another 60 se...

Page 41: ...le the system yourself the dismantling of the product treatment of the refrigerant of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legisl...

Page 42: ...NSOR C9 FAULTY SUCTION AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT IN...

Page 43: ...OTECTOR WORKED OR FREEZE UP IN OPERATING UNIT OR STAND BY UNIT FAULTY COMPRESSOR START INPUT OVERCURRENT HIGH TEMPERATURE SWITCHBOX HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK LOW VOLTAGE TO MAIN CI...

Page 44: ...0911 HT 3P248442 3 M08B300 Two dimensional barcodeisacode for manufacturing 00_CV_3P248442 3 fm Page 2 Tuesday September 8 2009 1 14 PM...

Reviews: