3-11
3. BATTERY MODE
POWER OFF
S
CONTROL
TEMPERATURE DISPLAY
S
CONTROL HUMIDITY
SETTING
S
RETURN AIR
TEMPERATURE DISPLAY
S
SUPPLY AIR
TEMPERATURE DISPLAY
S
DEFROST INTERVAL
SETTING
S
UNIT ON/OFF SETTING
S
key or Non operation for 30 seconds
S
FRESH AIR QUANTITY
DISPLAY
S
CONTROL
TEMPERATURE SETTING
LED display
(Light off)
(Light off)
(Light off)
LCD display
"SP C"
"SHU "
"dEF H"
Setting method
Change the value using the key or key.
Press the key to determine the setting.
Setting temperature range; –30 to +30˚C.
Change the value using the key or key.
Press the key to determine the setting.
Setting humidity range: 60 to 95%RH
Select a defrost interval 99h, 24h,12h,9h,6h or
3h using the key or key. Press the
key to determine the setting.
"On demand defrosting" is conducted when
"99h" has been selected. (See page 2-14.)
Item
–
–
–
–
–
–
(Light off)
(Light off)
RS
※※※
.
※
C
Note 1)
SS
※※※
.
※
C
Note 1)
–
(Light off)
FA
※※
(Light off)
SP
※※※
.
※
C
(Light off)
"UNIT ON" or
"UNIT OFF"
Change the value using the key or key.
Press the key to determine the setting.
Note 1). The inside sensor temperature is indicated on the section of
※※※
.
※
.
POWER OFF
BATTERY MODE
S
To change to the BATTERY MODE, press the
key while the unit is in
the POWER OFF STATUS.
In the BATTERY MODE, return air temperature/supply air temperature
can be indicated, Control temperature, Control humidity (optional),
Defrosting interval and Unit ON/OFF key can be set.
S
Select an item using the
key. The value of the selected item is indicated on the LCD screen.
When no key operation is performed for 30 seconds in the BATTERY MODE, the battery mode turns off
automatically off.
S
Non operation
for 30 seconds
If no indication on the LCD panel is displayed by
operating the key, it is supposed the wake-up battery is
dead.
Replace the battery.
CAUTION
When commercial power is not available, the following functions are available by using the built-in wake up
battery.
• Indication of inside supply air temperature (SS) and return air temperature (RS)
• Setting for control temperature, control humidity and defrost interval