12
Technical data
Installation and operating instructions
67
Gas Combi Unit
Floor-standing gas condensing boiler with integrated heat storage
008.1543899_02 – 04/2019 – EN
12
Technical data
12.1
Basic data
12.1.1
GCU compact 3xx
Type (1)
(22)
GCU compact
Individual
Unit
315 / 315 Biv
320 / 320 Biv
Permitted ambient temperature
°C
1 - 40
Total storage capacity
litres
294
Net weight (11)
(22)
kg
76 / 78
Total filled weight
kg
370 / 372
Dimensions (W × D × H)
cm
59.5 × 61.5 × 189.5
Maximum permissible storage water temperature
°C
85
Standby heating power
kWh/24 h
1.5
Drinking water heat exchanger (stainless steel)
Water capacity heat exchanger
litres
18.6
Heat exchanger surface area
m
2
3.8
Max. operating pressure for potable water P
MW
(14)
(22)
bar
6
Storage tank charging heat exchanger (stainless steel)
Water capacity heat exchanger
litres
8.7
Heat exchanger surface area
m
2
1.8
Pressurised solar heat exchanger (stainless steel)
Water capacity heat exchanger
litres
— / 3.9
Heat exchanger surface area
m
2
— / 0.7
Pipe connections
Cold and hot water
inches
1" outer thread
Heating feed and return flow
inches
1" outer thread
Thermal performance data (sanitary)
Output characteristic figure N
L
in accordance with DIN 4708
(23)
2.0
2.1
D value (specific water flow) conforms to EN 13203
(24)
(15)
(22)
l/min
22
23
Continuous output Q
D
according to DIN 4708
kW
15
20
Max. draw-off rate for a period of 10 min at
(T
KW
= 10 °C / T
WW
= 40 °C / T
SP
= 60 °C)
litres
19
20
Hot water quantity without reheating with up to 15 l/min draw-off
rate
(T
KW
= 10 °C / T
WW
= 40 °C / T
SP
= 60 °C)
litres
200
Hot water quantity with reheating at nominal output and 15 l/min
at draw-off rate
(T
KW
= 10 °C / T
WW
= 40 °C / T
SP
= 60 °C)
litres
300
350
Short-term water quantity in 10 min
(25)
litres
190
200
Electrical system
Maximum electrical power consumption
(without/with heating circulation pump) (9)
(22)
W
36 / 76
38 / 98
Max. electric power consumption in "Standby" operating mode
W
3.1
Voltage supply (8)
(22)
~230 V, 50 Hz
Degree of protection (10)
(22)
IP X0B
Tab. 12-1
Technical data for GCU compact 3xx
(22)
Value in brackets corresponds to item number in
(23)
Reheating with nominal output, inflow temp. T
V
= 80 °C, starting storage tank temp. T
SP
= 65 °C, cold water temp.
T
KW
= 10 °C, hot water temp. T
WW
= 45 °C.
(24)
The spec. water flow acc. to EN 13203 is the domestic water flow at an average temperature increase of 30 K, which the
GCU compact can supply if two draw-off procedures each of 10 minutes duration are performed one after the other, assum-
ing a charging temp. of 65 °C. A delay of 20 minutes between the two draw-off procedures is usually assumed. The
GCU compact achieves this value with even shorter waiting periods.
(25)
Reheating with nominal output, starting storage tank temp. T
SP
= 60 °C, cold water temp. T
KW
= 10 °C, hot water temp.
T
WW
= 40 °C.
Summary of Contents for GCU compact Series