![background image](http://html1.mh-extra.com/html/daikin/ftxg20lv1bw/ftxg20lv1bw_service-manual_4197882068.webp)
Service Diagnosis
SiBE041401E
57
Service Diagnosis
5. Diagnose by the sound.
★
beep: The left-side number does not correspond with the error code.
★
two consecutive beeps: The left-side number corresponds with the error code but the
right-side number does not.
★
long beep: Both the left-side and right-side numbers correspond with the error code.
(The numbers indicated when you hear the long beep are the error code.
→
Refer to page 58.)
6. Press the
Mode
button.
The right-side number blinks.
7. Press the
Temp
▲
or
Temp
▼
button
and change the number until you hear the long beep.
8. Diagnose by the sound.
★
beep: The left-side number does not correspond with the error code.
★
two consecutive beeps: The left-side number corresponds with the error code but the
right-side number does not.
★
long beep: Both the left-side and right-side numbers correspond with the error code.
9. Determine the error code.
The numbers indicated when you hear the long beep are the error code.
Error codes and description
→
Refer to page 58.
10.Press the
Mode
button for 5 seconds to exit from the service check mode.
(When the remote controller is left untouched for 60 seconds, it returns to the normal mode
also.)
(R11672)
(R11673)
(R11671)
(R11672)
Summary of Contents for FTXG20LV1BW
Page 12: ...SiBE041401E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 14: ...SiBE041401E 3 Specifications Part 2 Specifications 1 Specifications 4...
Page 60: ...SiBE041401E 49 Remote Controller Part 5 Remote Controller 1 Remote controller 50...
Page 113: ...SiBE041401E Check Service Diagnosis 102 50 class Diode bridge R19944...
Page 127: ...Revision History Month Year Version Revised contents 03 2014 SiBE041401E First edition...