![background image](http://html1.mh-extra.com/html/daikin/ftxg20lv1bw/ftxg20lv1bw_service-manual_4197882123.webp)
SiBE041401E
Piping Diagrams
Appendix
112
1. Piping Diagrams
1.1
Indoor Unit
1.2
Outdoor Unit
RXG20/25/35L2V1B
FTXG20/25/35LV1BW(S)
FTXG50LV1BW(S)
INDOOR UNIT
6.4CuT
FIELD PIPING
6.4CuT
FIELD PIPING
9.5CuT
9.5CuT
COOLING
HEAT
EXCHANGER
THERMISTOR
ON HEAT EXCH.
CROSS FLOW FAN
FAN MOTOR
REFRIGERANT FLOW
HEATING
4D085645
INDOOR UNIT
6.4CuT
FIELD PIPING
6.4CuT
FIELD PIPING
12.7CuT
9.5CuT
COOLING
THERMISTOR
ON HEAT EXCH.
CROSS FLOW FAN
FAN MOTOR
REFRIGERANT FLOW
HEATING
4D085834
HEAT
EXCHANGER
OUTDOOR UNIT
HEAT EXCHANGER
7.0 CuT
7.0 CuT
9.5 CuT
EV
4.8 CuT
6.4 CuT
6.4 CuT
4.8 CuT
M
φ
.4.0
x
ID
. 2.0 CuT
PROPELLER FAN
9.5 CuT
9.5 CuT
6.4 CuT
7.9 CuT
9.5 CuT
MUFFLER
9.5 CuT
9.5 CuT
COMPRESSOR
MUFFLER
MUFFLER
7.9 CuT
ACCUMULATOR
REFRIGERANT FLOW
COOLING
HEATING
OUTDOOR TEMPERATURE
THERMISTOR
HEAT EXCHANGER
THERMISTOR
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
ELECTRONIC
EXPANSION
VALVE
MUFFLER
WITH
FILTER
FIELD PIPING
(6.4 CuT)
FIELD PIPING
(9.5 CuT)
GAS STOP
VALVE
LIQUID STOP
VALVE
FOUR WAY
VALVE
ON:HEATING
DISCHARGE PIPE
THERMISTOR
3D059586T
Summary of Contents for FTXG20LV1BW
Page 12: ...SiBE041401E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 14: ...SiBE041401E 3 Specifications Part 2 Specifications 1 Specifications 4...
Page 60: ...SiBE041401E 49 Remote Controller Part 5 Remote Controller 1 Remote controller 50...
Page 113: ...SiBE041401E Check Service Diagnosis 102 50 class Diode bridge R19944...
Page 127: ...Revision History Month Year Version Revised contents 03 2014 SiBE041401E First edition...