Main Functions
SiBE041401E
35
Function and Control
1.16 Other Functions
1.16.1 Hot-Start Function
In order to prevent the cold air blast that normally occurs when heating operation is started, the
temperature of the indoor heat exchanger is detected, and the airflow is either stopped or
significantly weakened resulting in comfortable heating.
Note:
The cold air blast is prevented using similar control when defrost control starts or when the
thermostat is turned ON.
1.16.2 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
1.16.3 Indoor Unit ON/OFF Button
An
ON/OFF
button is provided on the display of the unit.
Press the
ON/OFF
button once to start operation. Press once again to stop it.
The
ON/OFF
button is useful when the remote controller is missing or the battery has run
out.
The operation mode refers to the following table.
<Forced cooling operation>
Forced cooling operation can be started by pressing the
ON/OFF
button for 5 to 9 seconds
while the unit is not operating.
Refer to page 104 for detail.
Note:
When the
ON/OFF
button is pressed for 10 seconds or more, the forced cooling operation is
stopped.
1.16.4 Auto-restart Function
If a power failure (including one for just a moment) occurs during the operation, the operation
restarts automatically when the power is restored in the same condition as before the power
failure.
Note:
It takes 3 minutes to restart the operation because the 3-minute standby function is activated.
Operation mode
Temperature setting
Airflow rate
AUTO
25ºC
Automatic
(R19927)
Indoor unit
ON/OFF
button
Summary of Contents for FTXG20LV1BW
Page 12: ...SiBE041401E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 14: ...SiBE041401E 3 Specifications Part 2 Specifications 1 Specifications 4...
Page 60: ...SiBE041401E 49 Remote Controller Part 5 Remote Controller 1 Remote controller 50...
Page 113: ...SiBE041401E Check Service Diagnosis 102 50 class Diode bridge R19944...
Page 127: ...Revision History Month Year Version Revised contents 03 2014 SiBE041401E First edition...