![background image](http://html1.mh-extra.com/html/daikin/ftxg20lv1bw/ftxg20lv1bw_service-manual_4197882025.webp)
SiBE041401E
Outdoor Unit
Printed Circuit Board Connector Wiring Diagram
14
Filter PCB (PCB1)
1) S11
Connector for S10 on main PCB
2) HL1, HN1, S
Connector for terminal board
3) E1, E2
Terminal for earth wire
4) HL2, HN2
Connector for HL3, HN3 on main PCB
5) HL4, HN4
Connector for S12 on main PCB
6) FU1
Fuse (3.15 A, 250 V)
7) FU3
Fuse (30 A, 250 V)
8) V2, V3
Varistor
9) SW1
Forced cooling operation ON/OFF button
∗
Refer to page 104 for detail.
to S50
(on main PCB)
S
HL1
HN1
V3
V2
FU3
SW1
FU1
HN4, HL4
HN2 HL2
S11
E1, E2
3P273862-4
Summary of Contents for FTXG20LV1BW
Page 12: ...SiBE041401E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 14: ...SiBE041401E 3 Specifications Part 2 Specifications 1 Specifications 4...
Page 60: ...SiBE041401E 49 Remote Controller Part 5 Remote Controller 1 Remote controller 50...
Page 113: ...SiBE041401E Check Service Diagnosis 102 50 class Diode bridge R19944...
Page 127: ...Revision History Month Year Version Revised contents 03 2014 SiBE041401E First edition...