Service Diagnosis
SiBE041401E
55
Service Diagnosis
3. Service Diagnosis
Method 1
1. When the timer cancel button is held down for 5 seconds,
00
is displayed on the temperature
display screen.
2. Press the timer cancel button repeatedly until a long beep sounds.
The code indication changes in the sequence shown below.
Note:
1. A short beep or two consecutive beeps indicate non-corresponding codes.
2. To return to the normal mode, hold the timer cancel button down for 5 seconds. When the
remote controller is left untouched for 60 seconds, it also returns to the normal mode.
3. Not all the error codes are displayed. When you cannot find the error code, try method 2.
(
→
Refer to page 56.)
No.
Code
No.
Code
No.
Code
1
00
13
C7
25
UA
2
U4
14
A3
26
UH
3
L5
15
H8
27
P4
4
E6
16
H9
28
L3
5
H6
17
C9
29
L4
6
H0
18
C4
30
H7
7
A6
19
C5
31
U2
8
E7
20
J3
32
EA
9
U0
21
J6
33
AH
10
F3
22
E5
34
FA
11
A5
23
A1
35
H1
12
F6
24
E1
36
P9
(R14553)
< ARC466 Series >
Timer cancel button
Summary of Contents for FTXG20LV1BW
Page 12: ...SiBE041401E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 14: ...SiBE041401E 3 Specifications Part 2 Specifications 1 Specifications 4...
Page 60: ...SiBE041401E 49 Remote Controller Part 5 Remote Controller 1 Remote controller 50...
Page 113: ...SiBE041401E Check Service Diagnosis 102 50 class Diode bridge R19944...
Page 127: ...Revision History Month Year Version Revised contents 03 2014 SiBE041401E First edition...