Removal Procedure
3
Lift up the fan motor
assembly and remove
it.
2. Remove the propeller fan.
Be careful of the fan fixing
nut, which is of left-hand
thread.
1
Dismount the propeller
fan by removing the
washer faced nut with
use of an open-ended
wrench.
Mount the fan propeller to
the fan motor so that the "
z
"
mark should face upward.
Step
Procedure
Points
M10
(R447
3
)
(R4474)
Horizontal face
goes upper side
The dot mark goes
vertically above the center.