![background image](http://html1.mh-extra.com/html/daikin/ftks20cvmb-9/ftks20cvmb-9_service-manual_4210114156.webp)
SiENBE04-512A
Indoor Unit
Removal Procedure
147
For restoring.
1. Since the key pattern hook
is provided on the left side,
insert the edge of the blade
to the tip while rotating it.
2. Restore the two fixed parts
of the horizontal blade onto
the hook.
2. Removal of vertical blade
1
Disengage the vertical
blade’s joint from the
fixed plate.
2
Remove the blade
forward.
Five vertical blades are
integrated with the joint rod.
(so, only one blade can’t be
exchanged.)
Step
Procedure
Points
Fixed pl
a
te
(R2527)
SiENBE04-512A.book Page 147 Friday, October 5, 2007 1:49 PM