Indoor Unit
SiENBE04-512A
140
Removal Procedure
1. Indoor Unit
1.1
Removal of Air Filter
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. External features
If ON/OFF button is kept
pushing for 5 seconds, a
forced cooling operation will
be carried out for approx. 15
minutes.
2. Removing air filters
1
Pull protrusions on left
and right sides of panel
with fingers and open
front grille all the way.
2
Lift center section of air
filter and disengage
hooks.
Remove air filter by
pulling forward.
Left and right filters are
interchangeable.
To re-install, insert air filter
along the guide.
ON/OFF
bu
tton
Receiver
Intelligent eye
(R2509)
Oper
a
tion
l
a
mp (Green)
HOME
LEAVE
l
a
mp
(Red)
Timer l
a
mp
(Yellow)
SiENBE04-512A.book Page 140 Friday, October 5, 2007 1:49 PM
Summary of Contents for FTKS20CVMB(9)
Page 1: ...SiENBE04 512A Service Manual Inverter Pair Wall Mounted Type C Series D Series...
Page 17: ...List of Functions SiENBE04 512A 8 List of Functions...
Page 37: ...Specifications SiENBE04 512A 28 Specifications...
Page 73: ...Control Specification SiENBE04 512A 64 Function and Control...
Page 103: ...Instruction SiENBE04 512A 94 System Configuration...
Page 147: ...Check SiENBE04 512A 138 Service Diagnosis...
Page 225: ...Outdoor Unit RK X H C ARK X H C R Y N C SiENBE04 512A 216 Removal Procedure...
Page 229: ...Others SiENBE04 512A 220 Others...
Page 241: ...Wiring Diagrams SiENBE04 512A 232 Appendix...