![background image](http://html1.mh-extra.com/html/daikin/ftks20cvmb-9/ftks20cvmb-9_service-manual_4210114182.webp)
SiENBE04-512A
Outdoor Unit / ARK(X)S-C
Removal Procedure
173
2.4
Removal of Sound Blanket
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Remove the outer panels.
Remove the electrical
box.
1. Remove the sound
blanket.
1
Untie the strings and
open the sound blanket.
2
Lift and remove the
sound blanket (body) as
it is opened.
Since the piping ports on the
sound blanket are torn
easily, remove the blanket
carefully.
3
Lift and remove the
sound blanket (top).
S
o
u
nd
b
l
a
nket
(R
3
271)
SiENBE04-512A.book Page 173 Friday, October 5, 2007 1:49 PM