Specifications
SiENBE04-512A
26
Specifications
1.2.3 Non-lnverter Models
50Hz 230V
Note:
MAX. interunit piping length: 15m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Models
Indoor Units
FTYN20CVMB9
FTYN25CVMB9
Outdoor Units
RYN20CVMB7
RYN25CVMB7
Cooling
Heating
Cooling
Heating
Capacity
Rated (Min.~Max.)
kW
2.0
2.6
2.25
2.85
Btu/h
6,800
8,850
7,650
9,700
kcal/h
1,720
2,240
1,940
2,450
Moisture Removal
L/h
0.9
—
1.2
—
Running Current (Rated)
A
3.3
4.0
3.7
4.4
Power Consumption
Rated (Min.~Max.)
W
620
760
700
835
Power Factor
%
81.7
82.6
82.3
82.5
COP (Rated)
W/W
3.23
3.42
3.21
3.41
Piping
Connections
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
9.5
φ
9.5
Drain
mm
φ
18.0
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Indoor Units
FTYN20CVMB9
FTYN25CVMB9
Front Panel Color
White
White
Air Flow Rate
m³/min
(cfm)
H
7.7 (272)
7.8 (275)
7.7 (272)
7.8 (275)
M
5.9 (208)
6.5 (230)
5.9 (208)
6.5 (230)
L
4.2 (148)
5.3 (187)
4.2 (148)
5.3 (187)
SL
—
—
—
—
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
18
18
Speed
Steps
5 Steps, Auto
5 Steps, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.18
0.18
0.18
0.18
Power Consumption (Rated)
W
40
40
40
40
Power Factor
%
96.6
96.6
96.6
96.6
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
mm
273×784×185
273×784×185
Packaged Dimensions (H×W×D)
mm
258×834×325
258×834×325
Weight
kg
7.5
7.5
Gross Weight
kg
11
11
Operation
Sound
H/M/L/SL
dBA
38 / 32 / 26 / —
38 / 33 / 28 / —
38 / 32 / 26 / —
38 / 33 / 28 / —
Sound Power
H
dBA
56
56
56
56
Outdoor Units
RYN20CVMB7
RYN25CVMB7
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Rotary Type
Hermetically Sealed Rotary Type
Model
5RS092XDH01
5RS092XDH01
Motor Output
W
650
650
Refrigerant
Oil
Type
RB68A
RB68A
Charge
L
0.320
0.320
Refrigerant
Type
R-410A
R-410A
Charge
kg
0.79
0.79
Air Flow Rate
m³/min (cfm)
H
29 (1,025)
25.5 (901)
29 (1,025)
25.5 (901)
L
—
—
—
—
Fan
Type
Propeller
Propeller
Motor Output
W
25
25
Running Current (Rated)
A
3.12
3.82
3.52
4.22
Power Consumption (Rated)
W
580
720
660
795
Power Factor
%
80.8
81.9
81.5
81.9
Starting Current
A
4.0
4.4
Dimensions (H×W×D)
mm
560×695×265
560×695×265
Packaged Dimensions (H×W×D)
mm
599×824×337
599×824×337
Weight
kg
31
31
Gross Weight
kg
36
36
Operation
Sound
H/L
dBA
46 / —
47 / —
46 / —
47 / —
Sound Power
H
dBA
61
62
61
62
Drawing No.
3D048310
3D048311
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Heating
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m
SiENBE04-512A.book Page 26 Friday, October 5, 2007 1:49 PM
Summary of Contents for FTKS20CVMB(9)
Page 1: ...SiENBE04 512A Service Manual Inverter Pair Wall Mounted Type C Series D Series...
Page 17: ...List of Functions SiENBE04 512A 8 List of Functions...
Page 37: ...Specifications SiENBE04 512A 28 Specifications...
Page 73: ...Control Specification SiENBE04 512A 64 Function and Control...
Page 103: ...Instruction SiENBE04 512A 94 System Configuration...
Page 147: ...Check SiENBE04 512A 138 Service Diagnosis...
Page 225: ...Outdoor Unit RK X H C ARK X H C R Y N C SiENBE04 512A 216 Removal Procedure...
Page 229: ...Others SiENBE04 512A 220 Others...
Page 241: ...Wiring Diagrams SiENBE04 512A 232 Appendix...