background image

15

English

3. The air conditioner operates but it does not 

sufficiently cool or heat.

Check if the air inlet or outlet of outdoor or 
indoor unit is blocked by obstacles. 
Remove the obstacle and make it well-venti-
lated.
The horizontal blades at the air outlet are 
closed while the unit stops.
Obstacles decrease the fan speed, and cause 
performance decrease and breakage when 
discharged air is suctioned.
They cause a waste of electricity, and that 
may stop the devices.

Check if the air filter is clogged.
Ask a qualified service person to clean the air 
filters.
A decrease in the airflow volume of the air 
conditioner will result and the performance of 
the air conditioner will be degraded and power 
consumption will increase if the air filter is 
clogged with dust or dirt.
In addition, this may cause dew condensation 
at the air outlet.
(Refer to “

8. MAINTENANCE

” on page 9.)

Check if the set temperature is not proper.
Set to an appropriate temperature, fan speed, 
and discharge direction.

Check if the FAN SPEED button is set to LOW 
SPEED.
Set to an appropriate temperature, fan speed, 
and discharge direction.

Check if the airflow direction is not proper. 
Set to an appropriate temperature, fan speed, 
and discharge direction.

Check if the doors or the windows are open.
Shut doors or windows to prevent wind from 
coming in.

Check if direct sunlight enters the room (when 
cooling).
Use curtains or blinds.

When there are too many inhabitants in the 
room (when cooling).

Check if the heat source of the room is exces-
sive (when cooling).

4. Operation was performed or stopped 

although the ON/OFF button was not 
pressed.

Are you sure that the ON/OFF timer operation 
is not used?
Turn off the ON/OFF timer.
Please refer to operation manual attached to 
the remote controller.

Are you sure that any remote control device is 
not connected?
Contact the central control room that directed 
the stop.

Are you sure that the display for centralized 
control is not lit?
Contact the central control room that directed 
the stop.

If the problem is not solved after checking the 
above points, please do not try to repair it 
yourself. 
In such cases, always ask your local dealer. 
At this time, please tell the symptom and 
model name (written on the model name 
plate).

If one of the following malfunctions occurs, take 
the measures shown below and contact your 
local dealer.

The air conditioner must be repaired by a qualified 
service person.

WARNING

When the air conditioner is malfunctioning 

(giving off a burning odor, etc.), turn off 

power to the air conditioner and contact your 

local dealer.

Continued operation under such circumstances may result 

in a failure, electric shocks or a fire. Contact your local 

dealer.

If a safety device such as a fuse, a power circuit 
breaker or an earth leakage breaker frequently 
actuates;

Measure:

Do not turn on the main power switch.

If the ON/OFF switch does not properly work;

Measure:

Turn off the main power switch.

If water leaks from the indoor unit.

Measure:

Stop the operation.

4PEN465376-1.book  Page 15  Wednesday, March 15, 2017  3:03 PM

Summary of Contents for FHA35AVEB

Page 1: ...OPERATION MANUAL FHA35AVEB FHA50AVEB FHA60AVEB FHA71AVEB FHA100AVEB FHA125AVEB FHA140AVEB Split system air conditioners...

Page 2: ...ed from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...

Page 3: ...h surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric s...

Page 4: ...properly to ensure complete drainage If drain piping is not carried out properly drain will not flow out Then dirt and debris may be accumulated in the drain piping and may cause water leakage If it...

Page 5: ...ally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units NOTE Contact your local dealer in case of changi...

Page 6: ...r unit DB Dry bulb temperature WB Wet bulb temperature The setting temperature range of the remote controller is 16 C to 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for i...

Page 7: ...nsation on the horizontal blade The remote controller displays the airflow direction that is set If the COOLING OPERATION is used when the indoor temperature is low frost forms on the heat exchanger o...

Page 8: ...et automatically so the remote controller does not display the fan speed and set temperature To efficiently lower the indoor temperature and humidity first use the COOLING OPERATION to lower the indoo...

Page 9: ...wn airflow direction in a position Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle th...

Page 10: ...fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured CAUTION Do not wash the air conditioner with water It may cause electric sho...

Page 11: ...ller after turning on the power The indication can be turned off whether in oper ation or at stop In case of BRC1E For details refer to the operation manual attached to the remote controller If the ai...

Page 12: ...G AFTER LONG STOP PERIOD Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and cause performance...

Page 13: ...ner does not restart immediately when TEMPERATURE SET TING button is returned to the former position after pushing the button If the OPERATION lamp lights the air condi tioner is in normal condition I...

Page 14: ...n starts Refer to MOVEMENT OF THE HORI ZONTAL BLADE page 8 The airflow direction display of the remote controller differs from the actual operation of the horizontal blades COOL AND PROGRAM DRY OPERA...

Page 15: ...decreases as little as possible Lower the indoor temperature using the COOLING OPERATION and then use the PROGRAM DRY OPERATION Refer to CHARACTERISTICS OF THE PROGRAM DRY OPERATION on page 7 Read th...

Page 16: ...blinds When there are too many inhabitants in the room when cooling Check if the heat source of the room is exces sive when cooling 4 Operation was performed or stopped although the ON OFF button was...

Page 17: ...accordance with relevant local and national legislation Units and waste batteries must be treated at a spe cialized treatment facility for re use recycling and recovery By ensuring correct disposal y...

Page 18: ......

Page 19: ......

Page 20: ...4P465376 1 2017 01 Copyright 2017 Daikin...