Turn off the power circuit breaker when it is not in 
use for a long period. When the power circuit 
breaker is turned on, small amount of power is 
consumed even if the air conditioner is not in oper-
ation. (*1)
Turn off the power circuit breaker for saving 
energy. When reoperating, turn on the power cir-
cuit breaker 6 hours before operation for smooth 
running.
(Refer to “

8. MAINTENANCE

” on page 9.) (*2)

*1 The consumed power while the outdoor unit is 

not in operation depends on the model.

*2 The setting before the power circuit breaker is 

cut off is stored. (The timer setting is cleared.)

Fully use the function of airflow direction adjust.
Cold air gathers on the floor, and warm air gathers 
under the ceiling.
Set the air direction to horizontal during the 
COOLING or PROGRAM DRY OPERATION, and 
set it downwards during the HEATING OPERA-
TION.
Do not let the air blow directly to a person.

Use the TIMER OPERATION effectively.
It takes some time until the indoor temperature 
reaches the set temperature. It is advisable to 
start operation in advance using the TIMER 
OPERATION.

8. MAINTENANCE

(FOR SERVICE PERSONNEL)

ONLY A QUALIFIED SERVICE PERSON IS 
ALLOWED TO PERFORM MAINTENANCE

WARNING

Do not use flammable gas (such as hair 
sprays and insecticides) near the air condi-
tioner.

Do not wipe the air conditioner with benzine or 
thinner.
It may cause cracks, electric shocks or a fire.

Never put your fingers or rods in the air inlet, 
air outlet or horizontal blade. The fan is rotat-
ing at high speed, so you would get injured.

CAUTION

Do not wash the air conditioner with water.
It may cause electric shocks or a fire due to leak-
age.

Make sure to turn off the air conditioner when 
taking care of the air conditioner and discon-
nect the power supply breaker.
Unless the power supply is disconnected, it 
may cause electric shocks and injuries.

When working at a high place, give caution to 
your footing.
If the scaffold is unstable, it may cause inju-
ries due to fall and stumbling.

NOTE 

Do not remove the air filter unless for clean-
ing. It may cause failure.

Do not attach substance (such as paper tow-
els) other than the specified air filter to the air 
inlet. The performance may drop and cause 
freeze-up/water leakage.

HOW TO CLEAN THE AIR FILTER

When the remote controller indicates “

” or “Time 

to clean filter”, clean the air filter.

It indicates after running for a certain time.

NOTE 

You may change the time of indication “

” or 

“Time to clean filter”.

If the indoor unit is used in a space where the 
air is more contaminated, ask your local 
dealer for solution.

If it becomes difficult to remove contamination 
from the air filter, replace the air filter. 
(Air filter for replacement is an optional acces-
sory)

1. Open the suction grille.

Slide the knob to the arrow direction and slowly 
open the grille.

Contamination

Time until indication is dis-
played

Normal

2500 hours
(equivalent to one year)

More contaminated

1250 hours
(equivalent to a half year)

Knob

Knobs

FHA35·50: 2 places

FHA60·71·100·125·140: 3 places

4PEN465376-1.book  Page 9  Wednesday, March 15, 2017  3:03 PM

Summary of Contents for FHA35AVEB

Page 1: ...OPERATION MANUAL FHA35AVEB FHA50AVEB FHA60AVEB FHA71AVEB FHA100AVEB FHA125AVEB FHA140AVEB Split system air conditioners...

Page 2: ...ed from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...

Page 3: ...h surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric s...

Page 4: ...properly to ensure complete drainage If drain piping is not carried out properly drain will not flow out Then dirt and debris may be accumulated in the drain piping and may cause water leakage If it...

Page 5: ...ally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units NOTE Contact your local dealer in case of changi...

Page 6: ...r unit DB Dry bulb temperature WB Wet bulb temperature The setting temperature range of the remote controller is 16 C to 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for i...

Page 7: ...nsation on the horizontal blade The remote controller displays the airflow direction that is set If the COOLING OPERATION is used when the indoor temperature is low frost forms on the heat exchanger o...

Page 8: ...et automatically so the remote controller does not display the fan speed and set temperature To efficiently lower the indoor temperature and humidity first use the COOLING OPERATION to lower the indoo...

Page 9: ...wn airflow direction in a position Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle th...

Page 10: ...fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured CAUTION Do not wash the air conditioner with water It may cause electric sho...

Page 11: ...ller after turning on the power The indication can be turned off whether in oper ation or at stop In case of BRC1E For details refer to the operation manual attached to the remote controller If the ai...

Page 12: ...G AFTER LONG STOP PERIOD Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and cause performance...

Page 13: ...ner does not restart immediately when TEMPERATURE SET TING button is returned to the former position after pushing the button If the OPERATION lamp lights the air condi tioner is in normal condition I...

Page 14: ...n starts Refer to MOVEMENT OF THE HORI ZONTAL BLADE page 8 The airflow direction display of the remote controller differs from the actual operation of the horizontal blades COOL AND PROGRAM DRY OPERA...

Page 15: ...decreases as little as possible Lower the indoor temperature using the COOLING OPERATION and then use the PROGRAM DRY OPERATION Refer to CHARACTERISTICS OF THE PROGRAM DRY OPERATION on page 7 Read th...

Page 16: ...blinds When there are too many inhabitants in the room when cooling Check if the heat source of the room is exces sive when cooling 4 Operation was performed or stopped although the ON OFF button was...

Page 17: ...accordance with relevant local and national legislation Units and waste batteries must be treated at a spe cialized treatment facility for re use recycling and recovery By ensuring correct disposal y...

Page 18: ......

Page 19: ......

Page 20: ...4P465376 1 2017 01 Copyright 2017 Daikin...

Reviews: