4. Clean the suction grille.

Wash the suction grille with water or neutral 
detergent using a soft brush and then dry it.

When the suction grille is extremely contaminated

Spray the detergent for a ventilating fans and 
ranges directly to the grille, and keep them under 
that condition for about 10 minutes.
After that, carefully wash the suction grille with 
water.

NOTE 

Do not wash the suction grille with water of 
50°C or higher.
It may cause discoloration and deformation.

When drying the suction grille, do not heat it 
with fire. It may cause burning.

Do not use such as gasoline, benzine, thinner, 
polishing powder and liquid insecticide sold 
in the market.
It may cause discoloration and deformation.

5. Attach the air filter.

Refer to the Clause 4 for “

HOW TO CLEAN THE 

AIR FILTER

”. (page 9)

6. Attach the suction grille.

Attach the grille in the reverse order mentioned 
in the Clause 2.

7. Close the suction grille.

Slide all the knobs in the reverse order men-
tioned in the Clause 1 and securely fix them.

HOW TO CLEAN AIR OUTLET, OUTSIDE 
PANEL, AND REMOTE CONTROLLER

Wipe them with a dry soft cloth.

When the stain cannot be wiped off, dip the cloth 
in the neutral detergent diluted with water and 
twist the cloth. After wiping off stain with this cloth, 
wipe them with dry cloth.

NOTE 

Do not use such as gasoline, benzine, thinner, 
polishing powder and liquid insecticide sold 
in the market.
It may cause discoloration and deformation.

Do not wash the filter with warm water of 50°C 
or higher. It may cause discoloration and 
deformation.

Detergent

CLEANING BEFORE AND AFTER SEA-
SONAL USE

STARTING AFTER LONG STOP PERIOD

Confirm the following

Check that the air inlet and outlet of indoor and 
outdoor unit are not blocked.
Remove any obstacle.
Obstacles decrease the fan speed, and cause 
performance decrease and breakage of the 
devices.

Clean the air filter

After cleaning the air filter, make sure to attach it.
(Refer to “

8. MAINTENANCE

” on page 9.)

For information on how to install, remove, or clean 
a optional sold air filter, refer to the user’s manual 
attached to the air filter.

Turn off the indication “

” or “Time to clean fil-

ter” displayed on the remote controller after turn-
ing on the power.
The indication can be turned off whether in oper-
ation or at stop.

<In case of BRC1E>

For details, refer to the operation manual 
attached to the remote controller. 

Turn on the power circuit breaker at least 6 
hours before operation.

This is required in order to activate the air condi-
tioner smoothly, and to protect air conditioner.

The display on the remote controller will be shown 
when the power circuit breaker is turned on.

HEATING OPERATION within 6 hours after the 
power is supplied to the air conditioner.

Some models perform the following operation to 
protect the devices.
If the HEATING OPERATION is performed within 
6 hours after the power is supplied to the air con-
ditioner, the indoor fan stops for about 10 minutes 
during the outdoor unit operation to protect the 
devices.
The above operation is performed not only at the 
time of installation, but every time the power cir-
cuit breaker is turned off/on.
For comfortable use, do not turn off the power cir-
cuit breaker during seasonal use of the HEATING 
OPERATION.

WHAT TO DO TO STOP THE AIR CONDI-
TIONER FOR A LONG PERIOD

Turn on FAN OPERATION for a half day on the 
fine day and dry the indoor unit.

This can prevent the causes of mold.

4PEN465376-1.book  Page 11  Wednesday, March 15, 2017  3:03 PM

Summary of Contents for FHA35AVEB

Page 1: ...OPERATION MANUAL FHA35AVEB FHA50AVEB FHA60AVEB FHA71AVEB FHA100AVEB FHA125AVEB FHA140AVEB Split system air conditioners...

Page 2: ...ed from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...

Page 3: ...h surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric s...

Page 4: ...properly to ensure complete drainage If drain piping is not carried out properly drain will not flow out Then dirt and debris may be accumulated in the drain piping and may cause water leakage If it...

Page 5: ...ally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units NOTE Contact your local dealer in case of changi...

Page 6: ...r unit DB Dry bulb temperature WB Wet bulb temperature The setting temperature range of the remote controller is 16 C to 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for i...

Page 7: ...nsation on the horizontal blade The remote controller displays the airflow direction that is set If the COOLING OPERATION is used when the indoor temperature is low frost forms on the heat exchanger o...

Page 8: ...et automatically so the remote controller does not display the fan speed and set temperature To efficiently lower the indoor temperature and humidity first use the COOLING OPERATION to lower the indoo...

Page 9: ...wn airflow direction in a position Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle th...

Page 10: ...fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured CAUTION Do not wash the air conditioner with water It may cause electric sho...

Page 11: ...ller after turning on the power The indication can be turned off whether in oper ation or at stop In case of BRC1E For details refer to the operation manual attached to the remote controller If the ai...

Page 12: ...G AFTER LONG STOP PERIOD Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and cause performance...

Page 13: ...ner does not restart immediately when TEMPERATURE SET TING button is returned to the former position after pushing the button If the OPERATION lamp lights the air condi tioner is in normal condition I...

Page 14: ...n starts Refer to MOVEMENT OF THE HORI ZONTAL BLADE page 8 The airflow direction display of the remote controller differs from the actual operation of the horizontal blades COOL AND PROGRAM DRY OPERA...

Page 15: ...decreases as little as possible Lower the indoor temperature using the COOLING OPERATION and then use the PROGRAM DRY OPERATION Refer to CHARACTERISTICS OF THE PROGRAM DRY OPERATION on page 7 Read th...

Page 16: ...blinds When there are too many inhabitants in the room when cooling Check if the heat source of the room is exces sive when cooling 4 Operation was performed or stopped although the ON OFF button was...

Page 17: ...accordance with relevant local and national legislation Units and waste batteries must be treated at a spe cialized treatment facility for re use recycling and recovery By ensuring correct disposal y...

Page 18: ......

Page 19: ......

Page 20: ...4P465376 1 2017 01 Copyright 2017 Daikin...

Reviews: