Turn off the power circuit breaker.

During the power circuit breaker is turned on, 
some watts of electricity is being used even if the 
air conditioner is not operating.
Turn off the power circuit breaker for saving 
energy.

The display on the remote controller will vanish 
when the power circuit breaker is turned off.

Clean the air filter and outside panel

Be sure to replace the air filter to its original place 
after cleaning. (Refer to “

8. MAINTENANCE

” on 

page 9.)
For information on how to install, remove, or clean 
an optional sold air filter, refer to the user’s man-
ual attached to the air filter.

NOTE 

The inside of the air conditioner may become con-
taminated after several seasons of use, potentially 
causing performance degradation and water leak-
age.
Ask your local dealer for details on cleaning the 
inside of the indoor unit. This operation requires a 
qualified service person.

9. NOT MALFUNCTION OF THE AIR 

CONDITIONER

The following symptoms do not indicate air con-
ditioner malfunction

HEATING OPERATION within 6 hours after the 
power is supplied to the air conditioner.
Some models perform the following operation to 
protect the devices.
If the HEATING OPERATION is performed within 6 
hours after the power is supplied to the air condi-
tioner, the indoor fan stops for about 10 minutes 
during the outdoor unit operation to protect the 
devices.
The above operation is performed not only at the 
time of installation, but every time the power cir-
cuit breaker is turned off/on.
For comfort heating, it is recommended not to turn 
off the power circuit breaker during the HEATING 
OPERATION.

I. THE AIR CONDITIONER DOES NOT OPERATE

The air conditioner does not restart imme-
diately after the ON/OFF button is pressed.

The air conditioner does not restart 
immediately when TEMPERATURE SET-
TING button is returned to the former 
position after pushing the button.

If the OPERATION lamp lights, the air condi-
tioner is in normal condition.
It does not restart immediately because a 
safety device operates to prevent overload of 
the air conditioner.
After approx. 3 minutes, the air conditioner 
will turn on again automatically.

The air conditioner does not start when 
the display shows “

” and it 

flashes for few seconds after pressing an 
operation button.

This is because the air conditioner is under 
centralized control.
Flashes on the display indicates that the air 
conditioner cannot be controlled by the 
remote controller.

HEATING OPERATION within 6 hours 
after the power is supplied to the air con-
ditioner.

Some models perform the following opera-
tion to protect the devices.
If the HEATING OPERATION is performed 
within 6 hours after the power is supplied to 
the air conditioner, the indoor fan stops for 
about 10 minutes during the outdoor unit 
operation to protect the devices.
The above operation is performed not only at 
the time of installation, but every time the 
power circuit breaker is turned off/on.
For comfortable use, do not turn off the 
power circuit breaker during seasonal use of 
the HEATING OPERATION.

The outdoor unit stops.

This is because the indoor temperature has 
reached the set temperature.
The indoor unit is in the FAN OPERATION.

COOLING OPERATION 
(AUTOMATIC COOLING OPERATION):
Lower the set temperature.
HEATING OPERATION 
(AUTOMATIC HEATING OPERATION):
Raise the set temperature.

The operation starts after a while when the 
air conditioner is in normal condition.

The remote controller displays “

”, 

and airflow stops.

This is because the air conditioner automati-
cally switches to the DEFROST OPERA-
TION to prevent a decrease in heating 
capacity when frost on the outdoor unit 
increases.
After maximum 10 minutes, the air condi-
tioner returns to its original operation.

4PEN465376-1.book  Page 12  Wednesday, March 15, 2017  3:03 PM

Summary of Contents for FHA35AVEB

Page 1: ...OPERATION MANUAL FHA35AVEB FHA50AVEB FHA60AVEB FHA71AVEB FHA100AVEB FHA125AVEB FHA140AVEB Split system air conditioners...

Page 2: ...ed from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...

Page 3: ...h surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric s...

Page 4: ...properly to ensure complete drainage If drain piping is not carried out properly drain will not flow out Then dirt and debris may be accumulated in the drain piping and may cause water leakage If it...

Page 5: ...ally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units NOTE Contact your local dealer in case of changi...

Page 6: ...r unit DB Dry bulb temperature WB Wet bulb temperature The setting temperature range of the remote controller is 16 C to 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for i...

Page 7: ...nsation on the horizontal blade The remote controller displays the airflow direction that is set If the COOLING OPERATION is used when the indoor temperature is low frost forms on the heat exchanger o...

Page 8: ...et automatically so the remote controller does not display the fan speed and set temperature To efficiently lower the indoor temperature and humidity first use the COOLING OPERATION to lower the indoo...

Page 9: ...wn airflow direction in a position Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle th...

Page 10: ...fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured CAUTION Do not wash the air conditioner with water It may cause electric sho...

Page 11: ...ller after turning on the power The indication can be turned off whether in oper ation or at stop In case of BRC1E For details refer to the operation manual attached to the remote controller If the ai...

Page 12: ...G AFTER LONG STOP PERIOD Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and cause performance...

Page 13: ...ner does not restart immediately when TEMPERATURE SET TING button is returned to the former position after pushing the button If the OPERATION lamp lights the air condi tioner is in normal condition I...

Page 14: ...n starts Refer to MOVEMENT OF THE HORI ZONTAL BLADE page 8 The airflow direction display of the remote controller differs from the actual operation of the horizontal blades COOL AND PROGRAM DRY OPERA...

Page 15: ...decreases as little as possible Lower the indoor temperature using the COOLING OPERATION and then use the PROGRAM DRY OPERATION Refer to CHARACTERISTICS OF THE PROGRAM DRY OPERATION on page 7 Read th...

Page 16: ...blinds When there are too many inhabitants in the room when cooling Check if the heat source of the room is exces sive when cooling 4 Operation was performed or stopped although the ON OFF button was...

Page 17: ...accordance with relevant local and national legislation Units and waste batteries must be treated at a spe cialized treatment facility for re use recycling and recovery By ensuring correct disposal y...

Page 18: ......

Page 19: ......

Page 20: ...4P465376 1 2017 01 Copyright 2017 Daikin...

Reviews: