II. THE OPERATION SOMETIMES STOPS

The remote controller displays “U4” and 
“U5”, and the operation stops. However, it 
will restart in a few minutes.

This is because communication between the 
indoor and outdoor units or indoor units and 
remote controllers is shut off and stops the 
operation due to noise caused by devices 
other than the air conditioner.
When the electrical noise decreases, the air 
conditioner automatically restarts.

III. THE FAN SPEED IS DIFFERENT FROM THE 

SETTING

Pressing the fan speed control button 
does not change the fan speed.

During the COOLING OPERATION, the low 
fan speed or a gentle wind is used to prevent 
the discharge of melt water.
During the DEFROST OPERATION (HEAT-
ING OPERATION), the wind from the air con-
ditioner stops to prevent air discharge 
directly toward your body.
After a while, the fan speed can be changed.
(The fan speed cannot be set for the PRO-
GRAM DRY OPERATION.)
When the room temperature reaches the set 
temperature during the HEATING OPERA-
TION, the outdoor unit stops and the indoor 
unit goes into gentle wind.
It takes some time until the fan speed 
changes. Raise the set temperature. After a 
while, the fan speed changes.

IV. THE AIRFLOW DIRECTION IS DIFFERENT 

FROM THE SETTING, OR THE AIRFLOW 
DIRECTION IS DIFFERENT FROM THE DIS-
PLAY ON THE REMOTE CONTROLLER

The horizontal blades do not swing when 
the remote controller displays the swing 
operation.

<HEATING OPERATION>

This is because the airflow direction is con-
trolled so it is horizontal direction after the 
operation starts or when the indoor tempera-
ture is higher than the set temperature to 
prevent air discharge directly toward your 
body.
After a while, the swing operation starts.
(Refer to “

MOVEMENT OF THE HORI-

ZONTAL BLADE

” page 8.)

The airflow direction display of the 
remote controller differs from the actual 
operation of the horizontal blades.

<COOL AND PROGRAM DRY OPERA-
TIONS>

When the operation in a downward airflow 
direction is set, the airflow direction differs 
from the display for a period of time to pre-
vent condensation on the horizontal blades.

<HEATING OPERATION>

This is because the airflow direction is con-
trolled so it is horizontal direction after the 
operation starts or when the indoor tempera-
ture is higher than the set temperature to 
prevent air discharge directly toward your 
body.
After a while, the airflow direction changes 
to the set direction.
(Refer to “

MOVEMENT OF THE HORI-

ZONTAL BLADE

” page 8.)

V. HORIZONTAL BLADES DO NOT CLOSE

The horizontal blades do not close even 
when operation stops.

This is because the horizontal blades close 
once airflow from the air conditioner stops.
After a while, the horizontal blades close.

VI. WHITE MIST COMES OUT OF THE AIR CON-

DITIONER

When humidity is high during the COOL-
ING OPERATION (In oily or dusty places)

If the inside of an indoor unit is extremely 
contaminated, the temperature distribution 
inside a room becomes uneven. It is neces-
sary to clean the inside of the indoor unit.
Ask your local dealer for details on cleaning 
the indoor unit.
This cleaning requires a qualified service 
person.
Check the usage environment.

When the air conditioner is changed over 
to the HEATING OPERATION after the 
DEFROST OPERATION and in the 
DEFROST OPERATION.

Moisture generated by defrost becomes 
steam and will float around.
When the remote controller display shows 

”, DEFROST OPERATION is being 

used.

VII. NOISE OF AIR CONDITIONERS

A ringing sound after the indoor unit 
starts.

This sound is generated when the motors for 
driving the horizontal blades are working.
It will quiet down after about a minute.

4PEN465376-1.book  Page 13  Wednesday, March 15, 2017  3:03 PM

Summary of Contents for FHA35AVEB

Page 1: ...OPERATION MANUAL FHA35AVEB FHA50AVEB FHA60AVEB FHA71AVEB FHA100AVEB FHA125AVEB FHA140AVEB Split system air conditioners...

Page 2: ...ed from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...

Page 3: ...h surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric s...

Page 4: ...properly to ensure complete drainage If drain piping is not carried out properly drain will not flow out Then dirt and debris may be accumulated in the drain piping and may cause water leakage If it...

Page 5: ...ally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units NOTE Contact your local dealer in case of changi...

Page 6: ...r unit DB Dry bulb temperature WB Wet bulb temperature The setting temperature range of the remote controller is 16 C to 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for i...

Page 7: ...nsation on the horizontal blade The remote controller displays the airflow direction that is set If the COOLING OPERATION is used when the indoor temperature is low frost forms on the heat exchanger o...

Page 8: ...et automatically so the remote controller does not display the fan speed and set temperature To efficiently lower the indoor temperature and humidity first use the COOLING OPERATION to lower the indoo...

Page 9: ...wn airflow direction in a position Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle th...

Page 10: ...fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured CAUTION Do not wash the air conditioner with water It may cause electric sho...

Page 11: ...ller after turning on the power The indication can be turned off whether in oper ation or at stop In case of BRC1E For details refer to the operation manual attached to the remote controller If the ai...

Page 12: ...G AFTER LONG STOP PERIOD Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and cause performance...

Page 13: ...ner does not restart immediately when TEMPERATURE SET TING button is returned to the former position after pushing the button If the OPERATION lamp lights the air condi tioner is in normal condition I...

Page 14: ...n starts Refer to MOVEMENT OF THE HORI ZONTAL BLADE page 8 The airflow direction display of the remote controller differs from the actual operation of the horizontal blades COOL AND PROGRAM DRY OPERA...

Page 15: ...decreases as little as possible Lower the indoor temperature using the COOLING OPERATION and then use the PROGRAM DRY OPERATION Refer to CHARACTERISTICS OF THE PROGRAM DRY OPERATION on page 7 Read th...

Page 16: ...blinds When there are too many inhabitants in the room when cooling Check if the heat source of the room is exces sive when cooling 4 Operation was performed or stopped although the ON OFF button was...

Page 17: ...accordance with relevant local and national legislation Units and waste batteries must be treated at a spe cialized treatment facility for re use recycling and recovery By ensuring correct disposal y...