background image

English

14

A low continuous flow “Shuh” sound 
which is heard when the air conditioner is 
in the COOLING or DEFROST OPERA-
TION or a trickling sound which is heard 
when the air conditioner is in the 
DEFROST OPERATION.

This is the sound of refrigerant gas flowing 
through both indoor and outdoor units.

A “Shuh” sound which is heard at the 
start or immediately after the stop of oper-
ation or which is heard at the start or 
immediately after the stop of the 
DEFROST OPERATION.

This is the noise of refrigerant caused by flow 
stop and flow change.
During the HEATING OPERATION, the air 
conditioner switches to the DEFROST 
OPERATION automatically.
The remote controller shows “

”.

After maximum 10 minutes, the air condi-
tioner returns to its original operation.

A “Pishi-pishi” squeaking sound is heard 
when the air conditioner is in operation or 
after the stop of operation.

Expansion and contraction of resin parts 
caused by temperature change makes this 
noise.

VIII. DUST FROM THE INDOOR UNITS

Dust may blow out from the unit after 
starting operation from long resting time.

Dust absorbed by the unit blows out.

IX. THE INDOOR UNITS GIVE OFF ODORS

During operation

The unit absorbs the smell of rooms, furni-
ture, cigarettes, etc., and then emits them.
If odor is a concern, you can set to zero fan 
speed when the indoor temperature reaches 
the set temperature.
For details, contact your local dealer.

X. THE AIR CONDITIONER DOES NOT COOL 

EFFECTIVELY

The air conditioner is operating in the 
PROGRAM DRY OPERATION.

This is because program dry mode operates 
so that the indoor temperature decreases as 
little as possible.
Lower the indoor temperature using the 
COOLING OPERATION, and then use the 
PROGRAM DRY OPERATION.
(Refer to “

CHARACTERISTICS OF THE 

PROGRAM DRY OPERATION

” on page 7.)

Read through characteristics of the 
COOLING OPERATION, characteristics of 
the HEATING OPERATION, and character-
istics of the PROGRAM DRY OPERATION 
on page 6-7.

10. TROUBLE SHOOTING

Please check before requesting a service.

1. If the air conditioner does not operate at all.

Check if fuse has blown.
Turn off the power supply.

Check if the power circuit breaker is blown.
If the tab of power circuit breaker is in the OFF 
position, turn the power on with the power cir-
cuit breaker switch.
If the tab of power circuit breaker is in the trip 
position do not turn the power on with the 
power circuit breaker switch.
Contact your local dealer.

Check if there is a power failure.
Wait until power is restored. If power failure 
occurs during operation, the air conditioner 
automatically restarts immediately after the 
power supply recovers.

2. If the air conditioner stops after operating the 

air conditioner.

Check if the air inlet or outlet of outdoor or 
indoor unit is blocked by obstacles. 
Remove the obstacle and make it well-venti-
lated.
The horizontal blades at the air outlet are 
closed while the indoor stops.

Check if the air filter is clogged.
Ask a qualified service person to clean the air 
filters. 
A decrease in the airflow volume of the air 
conditioner will result and the performance of 
the air conditioner will be degraded and power 
consumption will increase if the air filter is 
clogged with dust or dirt.
In addition, this may cause dew condensation 
at the air outlet.
(Refer to “

8. MAINTENANCE

” on page 9.)

Tab

Trip position

Power circuit breaker
(Earth leakage breaker)

ON

OFF

4PEN465376-1.book  Page 14  Wednesday, March 15, 2017  3:03 PM

Summary of Contents for FHA35AVEB

Page 1: ...OPERATION MANUAL FHA35AVEB FHA50AVEB FHA60AVEB FHA71AVEB FHA100AVEB FHA125AVEB FHA140AVEB Split system air conditioners...

Page 2: ...ed from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...

Page 3: ...h surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric s...

Page 4: ...properly to ensure complete drainage If drain piping is not carried out properly drain will not flow out Then dirt and debris may be accumulated in the drain piping and may cause water leakage If it...

Page 5: ...ally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units NOTE Contact your local dealer in case of changi...

Page 6: ...r unit DB Dry bulb temperature WB Wet bulb temperature The setting temperature range of the remote controller is 16 C to 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for i...

Page 7: ...nsation on the horizontal blade The remote controller displays the airflow direction that is set If the COOLING OPERATION is used when the indoor temperature is low frost forms on the heat exchanger o...

Page 8: ...et automatically so the remote controller does not display the fan speed and set temperature To efficiently lower the indoor temperature and humidity first use the COOLING OPERATION to lower the indoo...

Page 9: ...wn airflow direction in a position Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle th...

Page 10: ...fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured CAUTION Do not wash the air conditioner with water It may cause electric sho...

Page 11: ...ller after turning on the power The indication can be turned off whether in oper ation or at stop In case of BRC1E For details refer to the operation manual attached to the remote controller If the ai...

Page 12: ...G AFTER LONG STOP PERIOD Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and cause performance...

Page 13: ...ner does not restart immediately when TEMPERATURE SET TING button is returned to the former position after pushing the button If the OPERATION lamp lights the air condi tioner is in normal condition I...

Page 14: ...n starts Refer to MOVEMENT OF THE HORI ZONTAL BLADE page 8 The airflow direction display of the remote controller differs from the actual operation of the horizontal blades COOL AND PROGRAM DRY OPERA...

Page 15: ...decreases as little as possible Lower the indoor temperature using the COOLING OPERATION and then use the PROGRAM DRY OPERATION Refer to CHARACTERISTICS OF THE PROGRAM DRY OPERATION on page 7 Read th...

Page 16: ...blinds When there are too many inhabitants in the room when cooling Check if the heat source of the room is exces sive when cooling 4 Operation was performed or stopped although the ON OFF button was...

Page 17: ...accordance with relevant local and national legislation Units and waste batteries must be treated at a spe cialized treatment facility for re use recycling and recovery By ensuring correct disposal y...

Page 18: ......

Page 19: ......

Page 20: ...4P465376 1 2017 01 Copyright 2017 Daikin...

Reviews: