3. OPERATION RANGE

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.
COOLING                                                            [°C]*

* To avoid condensation and water dripping out the indoor unit.

DB: Dry bulb temperature
WB: Wet bulb temperature

   The setting temperature range of the remote controller is 16°C 

to 32°C depends on heating/cooling mode.

OUTDOOR UNIT

INDOOR

OUTDOOR 
TEMPERA-

TURE

TEMPERA-

TURE

HUMID-

ITY

RN50
RN60

DB 18 to 32

80%*or 

below

DB

– 10 to 

46

RKS35/50/60
RXS35/50/60

DB 18 to 32

80%*or 

below

DB

– 10 to 

46

4MKS58/75
3MXS52/68
4MXS68/80
5MXS90

DB 18 to 32

80%*or 

below

DB

– 10 to 

46

5MKS90

DB 18 to 32

80%*or 

below

DB

10 to 46

RZQ140/200/
250

DB 20 to 37 80%*or 

below

DB – 5 to 46

WB 14 to 28

RZQG 71/100/
125/140

DB 18 to 37 80%*or 

below

DB

– 15 to 

50

WB 12 to 28

RZQSG 71/100/
125 /140

DB 20 to 37 80%*or 

below

DB

– 15 to 

46

WB 14 to 28

OUTDOOR UNIT

INDOOR

OUTDOOR 
TEMPERA-

TURE

TEMPERA-

TURE

HUMID-

ITY

RXM35/50/60

DB 18 to 32

80%*or 

below

DB

– 10 to 

46

3MXM40/52/68
4MXM68/80
5MXM90

DB 18 to 32

80%*or 

below

DB

– 10 to 

46

RZAG71/100/
125/140

DB 18 to 37 80%*or 

below

DB

– 20 to 

52

WB 12 to 28

RZASG71/100/
125/140

DB 20 to 37 80%*or 

below

DB

– 15 to 

46

WB 14 to 28

HEATING                                                             [°C]*

* To avoid condensation and water dripping out the indoor unit.

DB: Dry bulb temperature
WB: Wet bulb temperature

   The setting temperature range of the remote controller is 16°C 

to 32°C depends on heating/cooling mode.

4. INSTALLATION SITE

Regarding places for installation

Is the air conditioner installed at a well-ventilated 
place where there are no obstacles around?

Do not use the air conditioner in the following 
places.

a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring 

resort

d. Where there are considerable voltage fluctua-

tions such as a factory or plant

e. Vehicles and vessels
 f. Where there is much spray of oil and vapor 

such as a cookery, etc.

g. Where there are machines generating electro-

magnetic waves

h. Filled with acid and/or alkaline steam or vapor

OUTDOOR UNIT

INDOOR

TEMPERATURE

OUTDOOR 

TEMPERATURE

RXS35/50/60

DB

10 to 30

DB

– 15 to 24

WB

– 16 to 18

3MXS52/68
4MXS68/80
5MXS90

DB

10 to 30

DB

– 15 to 24

WB

– 16 to 18

RZQG71/100/
125/140

DB

10 to 27

DB

–19.5 to 21

WB

–20 to 15.5

RZQ200/250

DB

10 to 27

DB

– 14 to 21

WB

– 15 to 15

RZQSG71

DB

10 to 27

DB

– 14 to 21

WB

–15 to 15.5

RZQSG100/125/
140

DB

10 to 27

DB

– 14 to 21

WB

–15 to 15.5

RZQ140

DB

10 to 27

DB

– 19.5 to 21

WB

– 20 to 15.5

OUTDOOR UNIT

INDOOR

TEMPERATURE

OUTDOOR 

TEMPERATURE

RXM35/50/60

DB

10 to 30

DB

– 15 to 24

WB

– 16 to 18

3MXM40/52/68
4MXM68/80
5MXM90

DB

10 to 30

DB

– 15 to 24

WB

– 16 to 18

RZAG71/100/125/
140

DB

10 to 27

DB

– 19.5 to 21

WB

– 20 to 15.5

RZASG71/100/125/
140

DB

10 to 27

DB

– 14 to 21

WB

– 15 to 15.5

4PEN465376-1.book  Page 5  Wednesday, March 15, 2017  3:03 PM

Summary of Contents for FHA35AVEB

Page 1: ...OPERATION MANUAL FHA35AVEB FHA50AVEB FHA60AVEB FHA71AVEB FHA100AVEB FHA125AVEB FHA140AVEB Split system air conditioners...

Page 2: ...ed from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...

Page 3: ...h surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric s...

Page 4: ...properly to ensure complete drainage If drain piping is not carried out properly drain will not flow out Then dirt and debris may be accumulated in the drain piping and may cause water leakage If it...

Page 5: ...ally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units NOTE Contact your local dealer in case of changi...

Page 6: ...r unit DB Dry bulb temperature WB Wet bulb temperature The setting temperature range of the remote controller is 16 C to 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for i...

Page 7: ...nsation on the horizontal blade The remote controller displays the airflow direction that is set If the COOLING OPERATION is used when the indoor temperature is low frost forms on the heat exchanger o...

Page 8: ...et automatically so the remote controller does not display the fan speed and set temperature To efficiently lower the indoor temperature and humidity first use the COOLING OPERATION to lower the indoo...

Page 9: ...wn airflow direction in a position Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle th...

Page 10: ...fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured CAUTION Do not wash the air conditioner with water It may cause electric sho...

Page 11: ...ller after turning on the power The indication can be turned off whether in oper ation or at stop In case of BRC1E For details refer to the operation manual attached to the remote controller If the ai...

Page 12: ...G AFTER LONG STOP PERIOD Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and cause performance...

Page 13: ...ner does not restart immediately when TEMPERATURE SET TING button is returned to the former position after pushing the button If the OPERATION lamp lights the air condi tioner is in normal condition I...

Page 14: ...n starts Refer to MOVEMENT OF THE HORI ZONTAL BLADE page 8 The airflow direction display of the remote controller differs from the actual operation of the horizontal blades COOL AND PROGRAM DRY OPERA...

Page 15: ...decreases as little as possible Lower the indoor temperature using the COOLING OPERATION and then use the PROGRAM DRY OPERATION Refer to CHARACTERISTICS OF THE PROGRAM DRY OPERATION on page 7 Read th...

Page 16: ...blinds When there are too many inhabitants in the room when cooling Check if the heat source of the room is exces sive when cooling 4 Operation was performed or stopped although the ON OFF button was...

Page 17: ...accordance with relevant local and national legislation Units and waste batteries must be treated at a spe cialized treatment facility for re use recycling and recovery By ensuring correct disposal y...

Page 18: ......

Page 19: ......

Page 20: ...4P465376 1 2017 01 Copyright 2017 Daikin...

Reviews: