background image

7

English

After maximum 10 minutes of the DEFROST 
OPERATION, the air conditioner returns to the 
HEATING OPERATION.

The airflow direction becomes horizontal. (The 
remote controller displays the airflow direction 
that is set.)

During or after the DEFROST OPERATION, white 
mist comes out from the air inlet or outlet of the air 
conditioner.
(Refer to “

VI.

” on page 13.)

A hissing and “Shuh” sound may be heard during 
this particular operation.

Regarding outside air temperature and heat-
ing capacity

The heating capacity of the air conditioner 
declines as the outside air temperature falls. In 
such a case, use the air conditioner in combina-
tion with other heating systems.
(When a combustion appliance is used, ventilate 
the room regularly.)
Do not use the combustion appliance where the air 
from the air conditioner is blown directly toward it.

When the warm air stays under the ceiling and 
your feet are cold, we recommend that you use a 
circulator (a fan to circulate the air inside the 
room). For details, consult your local dealer.

When the indoor temperature exceeds the set 
temperature, the indoor unit discharges a gentle 
breeze (switches to gentle wind). The airflow 
direction becomes horizontal. (The remote con-
troller displays the fan speed and airflow direction 
that are set.)

CHARACTERISTICS OF THE PROGRAM 
DRY OPERATION

This operation lowers the humidity without lower-
ing the indoor temperature. The indoor tempera-
ture when the operation button is pressed will be 
the set temperature. At this time, the fan speed 
and temperature are set automatically, so the 
remote controller does not display the fan speed 
and set temperature.
To efficiently lower the indoor temperature and 
humidity, first use the COOLING OPERATION to 
lower the indoor temperature, and then use the 
PROGRAM DRY OPERATION. When the indoor 
temperature is lowered, airflow from the air condi-
tioner may stop.

When operating continuously at downward airflow 
direction, air blows in the automatically set direc-
tion for a period of time to prevent condensation 
on the horizontal blade. (The remote controller dis-
plays the airflow direction that is set.)

If the PROGRAM DRY OPERATION is used 
when the indoor temperature is low, frost forms 
the heat exchanger of the indoor unit. In this case, 
the air conditioner automatically switches to the 
DEFROST OPERATION for a while.
The low fan speed or a gentle wind is used to pre-
vent the discharge of melt water.

SOUND PRESSURE LEVEL

Sound pressure level is less than 70 dB(A).

AIRFLOW DIRECTION ADJUST

There are 2 ways of adjusting the airflow direc-
tion.
(When the operation stops, the horizontal blades 
at the air outlet (Up and down direction adjust-
ment blades) close automatically.)

1.

A. Up and down direction (automatically)

2.

B. Left and right direction (manually)

A. UP AND DOWN DIRECTION

Press the AIRFLOW DIRECTION ADJUST 
button to select the air direction as following.

The AIRFLOW DIRECTION dis-
play swings as shown the left and 
the airflow direction continuously 
varies. (Automatic swing setting)

Press AIRFLOW DIRECTION 
ADJUST button to select the air 
direction of your choice.

The AIRFLOW DIRECTION dis-
play stops swinging and the air-
flow direction is fixed (Fixed 
airflow direction setting).

A. Up and down
    direction

B. Left and right direction

Fig. 2

swing

4PEN465376-1.book  Page 7  Wednesday, March 15, 2017  3:03 PM

Summary of Contents for FHA35AVEB

Page 1: ...OPERATION MANUAL FHA35AVEB FHA50AVEB FHA60AVEB FHA71AVEB FHA100AVEB FHA125AVEB FHA140AVEB Split system air conditioners...

Page 2: ...ed from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...

Page 3: ...h surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric s...

Page 4: ...properly to ensure complete drainage If drain piping is not carried out properly drain will not flow out Then dirt and debris may be accumulated in the drain piping and may cause water leakage If it...

Page 5: ...ally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units NOTE Contact your local dealer in case of changi...

Page 6: ...r unit DB Dry bulb temperature WB Wet bulb temperature The setting temperature range of the remote controller is 16 C to 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for i...

Page 7: ...nsation on the horizontal blade The remote controller displays the airflow direction that is set If the COOLING OPERATION is used when the indoor temperature is low frost forms on the heat exchanger o...

Page 8: ...et automatically so the remote controller does not display the fan speed and set temperature To efficiently lower the indoor temperature and humidity first use the COOLING OPERATION to lower the indoo...

Page 9: ...wn airflow direction in a position Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle th...

Page 10: ...fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured CAUTION Do not wash the air conditioner with water It may cause electric sho...

Page 11: ...ller after turning on the power The indication can be turned off whether in oper ation or at stop In case of BRC1E For details refer to the operation manual attached to the remote controller If the ai...

Page 12: ...G AFTER LONG STOP PERIOD Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and cause performance...

Page 13: ...ner does not restart immediately when TEMPERATURE SET TING button is returned to the former position after pushing the button If the OPERATION lamp lights the air condi tioner is in normal condition I...

Page 14: ...n starts Refer to MOVEMENT OF THE HORI ZONTAL BLADE page 8 The airflow direction display of the remote controller differs from the actual operation of the horizontal blades COOL AND PROGRAM DRY OPERA...

Page 15: ...decreases as little as possible Lower the indoor temperature using the COOLING OPERATION and then use the PROGRAM DRY OPERATION Refer to CHARACTERISTICS OF THE PROGRAM DRY OPERATION on page 7 Read th...

Page 16: ...blinds When there are too many inhabitants in the room when cooling Check if the heat source of the room is exces sive when cooling 4 Operation was performed or stopped although the ON OFF button was...

Page 17: ...accordance with relevant local and national legislation Units and waste batteries must be treated at a spe cialized treatment facility for re use recycling and recovery By ensuring correct disposal y...

Page 18: ......

Page 19: ......

Page 20: ...4P465376 1 2017 01 Copyright 2017 Daikin...