background image

English

6

Regarding wiring

All wiring must be performed by an qualified 
personnel.

To do wiring, ask your local dealer. Never do it by 
yourself.

Make sure that a separate power supply circuit 
is provided for this air conditioner and that all 
electrical work is carried out by qualified per-
sonnel according to local laws and regulations.

Pay attention to running noises, too

Are the following places selected?

a. A place that can sufficiently withstand the mass 

of the air conditioner with less running noises 
and vibrations.

b. A place where the hot wind discharged from the 

air outlet of the outdoor unit and the running 
noises do not cause a nuisance to neighbors.

Are you sure that there are no obstacles near 
the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

If abnormal noises occur in use, stop the oper-
ation of the air conditioner, consult your local 
dealer.

Regarding drainage of drain piping

Is the drain piping carried out properly to 
ensure complete drainage?

If drain piping is not carried out properly, dirt and 
debris may be accumulated in the drain piping 
and cause water leakage. If it occurs, stop the air 
conditioner and consult with your local dealer for 
assistance.

5. OPERATION PROCEDURE

Read the manual attached to the remote controller.

To protect the air conditioner, turn on the main 
power switch 6 hours before operation.

Do not shut off the power supply during seasonal 
use of the air conditioner.
This is required in order to activate the air condi-
tioner smoothly.

If the main power supply is turned off during oper-
ation, operation will restart automatically after the 
power turns back on again.

6. OPERATION CHARACTERISTICS

CHARACTERISTICS OF THE COOLING 
OPERATION (COOLING OPERATION AND 
AUTOMATIC COOLING OPERATION)

When operating continuously at downward airflow 
direction, air blows in the automatically set direc-
tion for a period of time to prevent condensation 
on the horizontal blade. (The remote controller 
displays the airflow direction that is set.)

If the COOLING OPERATION is used when the 
indoor temperature is low, frost forms on the heat 
exchanger of the indoor unit. This can decrease 
the cooling capacity. In this case, the air condi-
tioner automatically switches to the DEFROST 
OPERATION for a while.
During the DEFROST OPERATION, the low fan 
speed is used to prevent the discharge of melt 
water. (The remote controller displays the fan 
speed that is set.)

When the outdoor temperature is high, it takes 
some time until the indoor temperature reaches 
the set temperature.

CHARACTERISTICS OF THE HEATING 
OPERATION (HEATING OPERATION AND 
AUTOMATIC HEATING OPERATION)

START OF OPERATION

It generally takes a longer time for indoor tem-
perature of the HEATING OPERATION to reach 
the set temperature compared to the COOLING 
OPERATION. It is advisable to start operation in 
advance using the TIMER OPERATION.

Perform the following operation to prevent heat-
ing capacity decrease and discharge of cool air.

AT THE START OF OPERATION AND AFTER 
THE DEFROST OPERATION

A warm air circulating system is employed, and 
therefore it takes some time until the entire room 
is warmed up after the start of operation.

The indoor fan runs to discharge a gentle wind 
automatically until the temperature inside the air 
conditioner reaches a certain level. At this time, 
the remote controller displays “

”. Leave it 

as it stands and wait for a while.
(The remote controller displays the fan speed that 
is set.)

The airflow direction becomes horizontal to pre-
vent a draft of cool air to the inhabitants.
(The remote controller displays the airflow direc-
tion that is set.)

DEFROST OPERATION
(Frost removal operation for the outdoor 
unit)

As the frost on the heat exchanger of an outdoor 
unit increase, heating effect decreases and the air 
conditioner goes into the DEFROST OPERA-
TION.

The indoor unit fan stops and the remote control-
ler display shows “

”.

With the wireless remote controller, the warm air 
stops, and the DEFROST OPERATION lamp on 
the light receiving unit turn on. (The remote con-
troller displays the fan speed that is set.)

4PEN465376-1.book  Page 6  Wednesday, March 15, 2017  3:03 PM

Summary of Contents for FHA35AVEB

Page 1: ...OPERATION MANUAL FHA35AVEB FHA50AVEB FHA60AVEB FHA71AVEB FHA100AVEB FHA125AVEB FHA140AVEB Split system air conditioners...

Page 2: ...ed from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...

Page 3: ...h surge current from lightning or other sources may cause damage to the air conditioner Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric s...

Page 4: ...properly to ensure complete drainage If drain piping is not carried out properly drain will not flow out Then dirt and debris may be accumulated in the drain piping and may cause water leakage If it...

Page 5: ...ally set Two remote controllers control system Two remote controllers control one indoor unit In case of group control system one group of indoor units NOTE Contact your local dealer in case of changi...

Page 6: ...r unit DB Dry bulb temperature WB Wet bulb temperature The setting temperature range of the remote controller is 16 C to 32 C depends on heating cooling mode 4 INSTALLATION SITE Regarding places for i...

Page 7: ...nsation on the horizontal blade The remote controller displays the airflow direction that is set If the COOLING OPERATION is used when the indoor temperature is low frost forms on the heat exchanger o...

Page 8: ...et automatically so the remote controller does not display the fan speed and set temperature To efficiently lower the indoor temperature and humidity first use the COOLING OPERATION to lower the indoo...

Page 9: ...wn airflow direction in a position Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle th...

Page 10: ...fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured CAUTION Do not wash the air conditioner with water It may cause electric sho...

Page 11: ...ller after turning on the power The indication can be turned off whether in oper ation or at stop In case of BRC1E For details refer to the operation manual attached to the remote controller If the ai...

Page 12: ...G AFTER LONG STOP PERIOD Confirm the following Check that the air inlet and outlet of indoor and outdoor unit are not blocked Remove any obstacle Obstacles decrease the fan speed and cause performance...

Page 13: ...ner does not restart immediately when TEMPERATURE SET TING button is returned to the former position after pushing the button If the OPERATION lamp lights the air condi tioner is in normal condition I...

Page 14: ...n starts Refer to MOVEMENT OF THE HORI ZONTAL BLADE page 8 The airflow direction display of the remote controller differs from the actual operation of the horizontal blades COOL AND PROGRAM DRY OPERA...

Page 15: ...decreases as little as possible Lower the indoor temperature using the COOLING OPERATION and then use the PROGRAM DRY OPERATION Refer to CHARACTERISTICS OF THE PROGRAM DRY OPERATION on page 7 Read th...

Page 16: ...blinds When there are too many inhabitants in the room when cooling Check if the heat source of the room is exces sive when cooling 4 Operation was performed or stopped although the ON OFF button was...

Page 17: ...accordance with relevant local and national legislation Units and waste batteries must be treated at a spe cialized treatment facility for re use recycling and recovery By ensuring correct disposal y...

Page 18: ......

Page 19: ......

Page 20: ...4P465376 1 2017 01 Copyright 2017 Daikin...