15 Technical data
Installer reference guide
94
ERLQ004~008CA + 08S18CA3VF
Daikin Altherma low temperature split
4P3662261 – 2014.01
Heating only type
Indoor units
EHVH04S18CA3VF
EHVH08S18CA3VF
Connected to outdoor unit
ERLQ004CAV3
ERLQ006CAV3 ERLQ008CAV3
Safety devices
Thermal cut out
1
Water circuit space heating side
Piping connections Ø
(7)
G 11/4 female
Safety valve
3 bar
Manometer
Yes
Drain valve/fill valve
Yes
Shutoff valves
Yes
Air purge valve
Yes
Total water volume
(6)
4.4 l
4.8 l
Water circuit domestic hot water side
Pipe connections
Cold water in/hot water out Ø
G 1" female
Recirculation connection
G 1/2" female
Refrigerant circuit
Gas side
Ø15.9 mm
Liquid side
Ø6.35 mm
Sound level
Sound power
(3)
Nominal flow (heating)
42 dBa
Sound pressure
(4)
Nominal flow (heating)
28 dBa
Operation range
(9)
Ambient
Space heating
–25~25°C
Domestic hot water
–25~35°C
Water side
Space heating
(5)
15~55°C
Domestic hot water
(10)
25~60°C
(1)
Heatloss according to EN12897.
(2)
Ambient temperature 35°C – leaving water evaporator 7°C (DT=5°C).
(3)
DB/WB 7°C/6°C – leaving water condenser 35°C (DT=5°C).
(4)
The sound pressure level is measured via a microphone at 1 m from the unit. It is a relative value, depending on the distance and acoustic
environment. The sound pressure level mentioned is valid for pump medium speed – 0 external static pressure/medium speed – nominal flow/
high speed – nominal flow.
(5)
15°C~25°C: backup heater only, no heat pump operation during commissioning..
(6)
Including piping, plate heat exchanger, and backup heater/excluding expansion vessel.
(7)
Value mentioned is connection after ball valves. It is the same as the connection at the unit (G 11/4" female).
(8)
Ambient temperature 35°C – leaving water evaporator 18°C (DT=5°C).
(9)
For details, see operation range drawing.
(10)
For outdoor units: >55°C backup heater only, no heat pump operation.
(11)
Minimum flow is mentioned for heat pump operation. To allow backup heater to operate safely, a higher minimum flow is required: 12 l/min.
(12)
Refer to operation range for details.
(13)
DB/WB 7°C/6°C – leaving water condenser 45°C (DT=5°C).