Code
Description
[A.3.1.1.3]
[100]
[101]
[102]
[103]
<< continuation
▪ [100]:
Low
outdoor
ambient
temperature. −20°C~5°C (default:
−10°C)
▪ [101]:
High
outdoor
ambient
temperature. 10°C~20°C (default:
15°C)
▪ [102]:
Desired
leaving
water
temperature
when
the
outdoor
temperature equals or drops below
the low ambient temperature.
Between minimum and maximum
leaving water temperature (default:
35°C).
Note:
This value should be higher
than [103] as for low outdoor
temperatures
warmer
water
is
required.
▪ [103]:
Desired
leaving
water
temperature
when
the
outdoor
temperature equals or rises above
the high ambient temperature.
Between minimum and maximum
leaving water temperature (default:
25°C).
Note:
This value should be lower
than [102] as for high outdoor
temperatures less warm water is
required.
Leaving water temperature: Additional zone
Only applicable if 2 leaving water temperature zones are present.
#
Code
Description
[A.3.1.2.1]
N/A
LWT setpoint mode:
▪ Absolute
(default):
The
desired
leaving water temperature is:
▪ NOT weatherdependent (i.e. does
NOT depend on the outdoor
ambient temperature)
▪ fixed in time (i.e., NOT scheduled)
▪ Weather dep. The desired leaving
water temperature is:
▪ weatherdependent (i.e. depends
on
the
outdoor
ambient
temperature)
▪ fixed in time (i.e., NOT scheduled)
continued >>
#
Code
Description
[A.3.1.2.1]
N/A
<< continuation
▪ Abs + scheduled: The desired
leaving water temperature is:
▪ NOT
weatherdependent
(i.e.,
does NOT depend on the outdoor
ambient temperature)
▪ according
a
schedule.
The
scheduled actions are On or OFF.
Remark:
This value can only be
set in leaving water temperature
control.
▪ WD + scheduled: The desired
leaving water temperature is:
▪ weatherdependent
(i.e.,
does
depend on the outdoor ambient
temperature)
▪ according
a
schedule.
The
scheduled actions are On or OFF.
Remark:
This value can only be
set in leaving water temperature
control.
#
Code
Description
[A.3.1.2.3]
[000]
[001]
[002]
[003]
Set weatherdependent heating:
[0-00]
[0-01]
Ta
Tt
[0-03]
[0-02]
▪ T
t
: Target leaving water temperature
(main)
▪ T
a
: Outdoor temperature
continued >>