3/8
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
User settings
└─
Preset values
└─
Room temperature
7.4.1.1
R/W
[3-07]~[3-06], step: A.3.2.4
21°C
7.4.1.2
R/W
[3-07]~[3-06], step: A.3.2.4
19°C
└─
LWT main
7.4.2.1
[8-09]
R/W
[9-01]~[9-00], step: 1°C
35°C
7.4.2.2
[8-0A]
R/W
[9-01]~[9-00], step: 1°C
33°C
7.4.2.5
R/W
-10~10°C, step: 1°C
0°C
7.4.2.6
R/W
-10~10°C, step: 1°C
-2°C
└─
Tank temperature
7.4.3.1
[6-0A]
R/W
30~80°C, step: 1°C
60°C
7.4.3.2
[6-0B]
R/W
30~50°C, step: 1°C
45°C
7.4.3.3
[6-0C]
R/W
30~50°C, step: 1°C
45°C
└─
Quiet level
7.4.4
R/W
0: Level 1
1: Level 2
2: Level 3
Installer settings
└─
System layout
└─
Standard
A.2.1.1
[E-00]
R/O
0: LT split
A.2.1.2
[E-01]
R/O
0:08
A.2.1.3
[E-02]
R/O
1: Type 2
A.2.1.4
[E-03]
R/O
1: 1 step
A.2.1.5
[5-0D]
R/W
1: 1P,(1/1+2)
A.2.1.6
[D-01]
R/W
0: No
1: Active open
2: Active closed
A.2.1.7
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
A.2.1.8
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
A.2.1.9
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
A.2.1.A
[E-04]
R/O
1: Yes
A.2.1.B
R/W
0: At unit
1: In room
└─
Options
A.2.2.1
[E-05]
R/W
1: Yes
A.2.2.3
[E-07]
R/W
1: Backup heater
A.2.2.4
[C-05]
R/W
0: -
1: Thermo ON/OFF
2: C/H request
A.2.2.5
[C-06]
R/W
0: -
1: Thermo ON/OFF
2: C/H request
A.2.2.6.1
[C-02]
Digital I/O PCB
Ext. backup heat src
R/W
0: No
1: Bivalent
2: -
3: -
A.2.2.6.2
[D-07]
Digital I/O PCB
Solar kit
R/W
0: No
A.2.2.6.3
[C-09]
Digital I/O PCB
Alarm output
R/W
0: Normally open
1: Normally closed
A.2.2.6.4
[F-04]
Digital I/O PCB
Bottom plate heater
R/W
0: No
1: Yes
A.2.2.7
[D-04]
R/W
0: No
1: Yes
A.2.2.8
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.2.2.9
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.2.2.A
[D-02]
R/W
0: No
1: Secondary rtrn
2: Disinf. shunt
A.2.2.B
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
└─
Capacities
A.2.3.2
[6-03]
R/W
0~10kW, step: 0,2kW
3kW
Space operation
└─
LWT settings
└──────────────────
Main
A.3.1.1.1
R/W
0: Absolute
1: Weather dep.
2: Abs + scheduled
3: WD + scheduled
A.3.1.1.2.1
[9-01]
Temperature range
Minimum temp (heating)
R/W
15~37°C, step: 1°C
25°C
A.3.1.1.2.2
[9-00]
Temperature range
Maximum temp (heating)
R/W
37~55°C, step: 1°C
55°C
A.3.1.1.3
[1-00]
Set weather-dependent heating
Low ambient temp. for LWT main zone heating
WD curve.
R/W
-20~5°C, step: 1°C
-10°C
A.3.1.1.3
[1-01]
Set weather-dependent heating
High ambient temp. for LWT main zone heating
WD curve.
R/W
10~20°C, step: 1°C
15°C
External kWh meter 1
External kWh meter 2
DHW pump
External sensor
BUH: step 1
LWT setpoint mode
User interface location
DHW operation
DHW tank heater
Contact type main
Contact type add.
Demand PCB
BUH type
Preferential kWh rate
Unit control method
Number of LWT zones
Pump operation mode
Power saving possible
Installer setting at variance with
default value
Comfort (heating)
Eco (heating)
Comfort (heating)
Eco (heating)
Comfort (heating)
Field settings table
Indoor software type
Backup heater steps
Eco (heating)
Storage comfort
Storage eco
Reheat
Unit type
Compressor type
EHVH0*S18CA3VF
4P366223-1 - 2014.02