![background image](http://html1.mh-extra.com/html/daikin/erlq004cav3/erlq004cav3_installers-reference-manual_4059854104.webp)
6/8
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
Installer setting at variance with
default value
Field settings table
A.8.31
[2-09]
R/W
-5~5°C, step: 0,5°C
0°C
A.8.32
[2-0A]
R/W
-5~5°C, step: 0,5°C
0°C
A.8.33
[2-0B]
R/W
-5~5°C, step: 0,5°C
0°C
A.8.34
[3-00]
R/W
0: No
1: Yes
A.8.35
[3-01]
0
A.8.36
[3-02]
1
A.8.37
[3-03]
4
A.8.38
[3-04]
2
A.8.39
[3-05]
1
A.8.40
[3-06]
R/W
18~30°C, step: A.3.2.4
30°C
A.8.41
[3-07]
R/W
12~18°C, step: A.3.2.4
12°C
A.8.42
[3-08]
R/W
35
A.8.43
[3-09]
R/W
15
A.8.44
[4-00]
R/W
0: Limit
1: Enable
2: Only DHW
A.8.45
[4-01]
R/W
0: None
1: BSH
2: BUH
A.8.46
[4-02]
R/W
14~25°C, step: 1°C
25°C
A.8.47
[4-03]
R/W
3
A.8.48
[4-04]
2
A.8.49
[4-05]
0
A.8.50
[4-06]
R/W
0: No
1: Yes
A.8.51
[4-07]
R/W
1
A.8.52
[4-08]
R/W
0: No limitation
1: Continuous
2: Digital inputs
A.8.53
[4-09]
R/W
0: Current
1: Power
A.8.54
[4-0B]
R/W
1
A.8.55
[4-0D]
R/W
3
A.8.56
[5-00]
R/W
0: Allowed
1: Not allowed
A.8.57
[5-01]
R/W
-15~35°C, step: 1°C
0°C
A.8.58
[5-02]
R/W
1: Enabled
A.8.59
[5-03]
R/W
-15~35°C, step: 1°C
0°C
A.8.60
[5-04]
R/W
0~20°C, step: 1°C
10°C
A.8.61
[5-05]
R/W
0~50 A, step: 1 A
50 A
A.8.62
[5-06]
R/W
0~50 A, step: 1 A
50 A
A.8.63
[5-07]
R/W
0~50 A, step: 1 A
50 A
A.8.64
[5-08]
R/W
0~50 A, step: 1 A
50 A
A.8.65
[5-09]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8.66
[5-0A]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8.67
[5-0B]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8.68
[5-0C]
R/W
0~20 kW, step: 0,5 kW
20 kW
A.8.69
[5-0D]
R/W
1: 1P,(1/1+2)
A.8.70
[6-00]
R/O
10°C
A.8.71
[6-01]
R/W
0~10°C, step: 1°C
2°C
A.8.72
[6-02]
R/W
0
A.8.73
[6-03]
R/W
0~10kW, step: 0,2kW
3kW
A.8.74
[6-04]
R/W
0
A.8.75
[6-05]
0
A.8.76
[6-06]
0
A.8.78
[6-08]
10
A.8.79
[6-09]
0
A.8.80
[6-0A]
R/W
30~80°C, step: 1°C
60°C
A.8.81
[6-0B]
R/W
30~50°C, step: 1°C
45°C
A.8.82
[6-0C]
R/W
30~50°C, step: 1°C
45°C
A.8.83
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
A.8.84
[6-0E]
R/W
40~60°C, step: 1°C
60°C
A.8.85
[7-00]
R/W
0
A.8.86
[7-01]
R/W
2
A.8.87
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
A.8.88
[8-00]
R/W
0~20 min, step: 1 min
5 min
A.8.89
[8-01]
R/W
5~95 min, step: 5 min
30 min
A.8.90
[8-02]
R/W
0~10 hour, step: 0,5 hour
0,5 hour
A.8.91
[8-03]
R/W
50
A.8.92
[8-04]
R/W
0~95 min, step: 5 min
95 min
A.8.93
[8-05]
R/W
0: No
1: Yes
A.8.94
[8-06]
R/W
1~5°C, step: 1°C
3°C
--
Additional running time for the maximum running time.
Allow modulation of the LWT to control the room?
Leaving water temperature maximum modulation.
--
--
How many leaving water temperature zones are there?
Minimum running time for domestic hot water operation.
Maximum running time for domestic hot water operation.
Anti-recycling time.
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
What is the desired setpoint mode in DHW?
What is the maximum tank temperature setpoint?
--
What is the capacity of the backup heater step 1?
--
--
--
What is the reheat hysteresis? [6-0C]
What is the requested limit for DI2?
What is the requested limit for DI3?
What is the requested limit for DI4?
What type of backup heater installation is used?
The temperature difference determining the heat pump ON temperature.
The temperature difference determining the heat pump OFF temperature.
Set point correction for domestic hot water temperature.
What is the requested limit for DI1?
What is the requested limit for DI2?
What is the requested limit for DI3?
What is the requested limit for DI4?
What is the requested limit for DI1?
Which power limitation type is required?
--
--
What is the equilibrium temperature for the building?
Space heating priority.
Space heating priority temperature.
Is backup heater operation allowed above equilibrium temperature during space
heating operation?
--
--
--
Is the backup heater allowed during emergency operation?
--
Which power limitation mode is required on the system?
What is the mimimum desired room temperature in heating?
--
--
What is the BUH operation mode?
Which electric heater has priority?
Below which outdoor temperature is heating allowed?
--
--
--
--
--
What is the maximum desired room temperature in heating?
Adjust the offset on the measured room temperature
Adjust the offset on the measured room temperature
What is the required offset on the measured outdoor temp.?
Is auto restart of the unit allowed?
4P366223-1 - 2014.02
EHVH0*S18CA3VF