![background image](http://html1.mh-extra.com/html/daikin/erlq004cav3/erlq004cav3_installers-reference-manual_4059854093.webp)
15 Technical data
Installer reference guide
93
ERLQ004~008CA + 08S18CA3VF
Daikin Altherma low temperature split
4P3662261 – 2014.01
15.5.2
Technical specifications: Indoor unit
Technical specifications
Heating only type
Indoor units
EHVH04S18CA3VF
EHVH08S18CA3VF
Connected to outdoor unit
ERLQ004CAV3
ERLQ006CAV3 ERLQ008CAV3
Nominal input (indoor unit only)
75 W
Casing
Colour
White
Material
Precoated sheetmetal
Dimensions
Packing (H×W×D)
922×690×818 mm
Unit (H
(1)
×W×D)
1732×600×728 mm
Weight of machine (net)
120 kg
121 kg
Weight of machine (packed)
133 kg
134 kg
Packing materials
Material
Wood – carton – PE wrapping foil
Weight
12 kg
PED
Category of unit
Art. 3.3(*)
Category I
Most critical part
—
Plate heat exchanger
Ps*V
—
51 bar
Ps*DN
—
Main components hydrobox
Pump
Type
DC motor
Nr. of speed
Inverter controlled
Nominal ESP unit
Heating
(3)
52 kPa
49 kPa
37 kPa
Heating
(13)
55 kPa
51 kPa
41 kPa
Power input
46 W
Water side heat exchanger
Type
Brazed plated
Quantity
1
Water volume
0.9 l
1.3 l
Minimum water flow rate
5 l/min
11 l/min
Nominal water flow rate
Heating
(3)
12.6 l/min
17.2 l/min
21.2 l/min
Heating
(13)
11.6 l/min
16.3 l/min
19.8 l/min
Maximum water flow rate
Heating
25 l/min
34 l/min
Insulation material
EPS
Expansion vessel
Volume
10 l
Maximum water pressure
3 bar
Prepressure
1 bar
Water filter
Diameter perforations
1
Material
brass + stainless steel
Main components tank
Tank
Water volume
180 l
Material
Stainless steel (EN1.4521)
Maximum temperature
65°C
Maximum pressure
10 bar
Insulation material
EPS
Corrosion protection
Anode
Heatloss
(1)
1.4 kWh/24 h
Heat exchanger
Quantity
1
Material
Stainless steel (EN1.4521)
Surface
1.9 m
2
Internal coil volume
8.9 l
3way valve
Flow factor space heating/tank heating
13/8 m
3
/h